993 resultados para TEST BATTERY
Resumo:
No fully effective treatment has been developed since the discovery of Chagas' disease by Carlos Chagas in 1909. Since drug-resistant Trypanosoma cruzi strains are occurring and the current therapy is effectiveness in the acute phase but with various adverse side effects, more studies are needed to characterize the susceptibility of T. cruzi to new drugs. Many natural and/or synthetic substances showing trypanocidal activity have been used, even though they are not likely to be turned into clinically approved drugs. Originally, drug screening was performed using natural products, with only limited knowledge of the molecular mechanism involved in the development of diseases. Trans-splicing, which is unusual RNA processing reaction and occurs in nematodes and trypanosomes, implies the processing of polycistronic transcription units into individual mRNAs; a short transcript spliced leader (SL RNA) is trans-spliced to the acceptor pre-mRNA, giving origin to the mature mRNA. In the present study, permeable cells of T. cruzi epimastigote forms (Y, BOL and NCS strains) were treated to evaluate the interference of two drugs (hydroxymethylnitrofurazone - NFOH-121 and nitrofurazone) in the trans-splicing reaction using silver-stained PAGE analysis. Both drugs induced a significant reduction in RNA processing at concentrations from 5 to 12.5 µM. These data agreed with the biological findings, since the number of parasites decreased, especially with NFOH-121. This proposed methodology allows a rapid and cost-effective screening strategy for detecting drug interference in the trans-splicing mechanism of T. cruzi.
Resumo:
A method for the screening of tetanus and diphtheria antibodies in serum using anatoxin (inactivated toxin) instead of toxin was developed as an alternative to the in vivo toxin neutralization assay based on the toxin-binding inhibition test (TOBI test). In this study, the serum titers (values between 1.0 and 19.5 IU) measured by a modified TOBI test (Modi-TOBI test) and toxin neutralization assays were correlated (P < 0.0001). Titers of tetanus or diphtheria antibodies were evaluated in serum samples from guinea pigs immunized with tetanus toxoid, diphtheria-tetanus or triple vaccine. For the Modi-TOBI test, after blocking the microtiter plates, standard tetanus or diphtheria antitoxin and different concentrations of guinea pig sera were incubated with the respective anatoxin. Twelve hours later, these samples were transferred to a plate previously coated with tetanus or diphtheria antitoxin to bind the remaining anatoxin. The anatoxin was then detected using a peroxidase-labeled tetanus or diphtheria antitoxin. Serum titers were calculated using a linear regression plot of the results for the corresponding standard antitoxin. For the toxin neutralization assay, L+/10/50 doses of either toxin combined with different concentrations of serum samples were inoculated into mice for anti-tetanus detection, or in guinea pigs for anti-diphtheria detection. Both assays were suitable for determining wide ranges of antitoxin levels. The linear regression plots showed high correlation coefficients for tetanus (r² = 0.95, P < 0.0001) and for diphtheria (r² = 0.93, P < 0.0001) between the in vitro and the in vivo assays. The standardized method is appropriate for evaluating titers of neutralizing antibodies, thus permitting the in vitro control of serum antitoxin levels.
Resumo:
In order to evaluate the performance of a 1-h 75-g oral glucose tolerance test (OGTT) for the diagnosis of gestational diabetes mellitus (GDM), a cohort of 4998 women, 20 years or older, without previous diabetes being treated in prenatal care clinics in Brazil answered a questionnaire and performed a 75-g OGTT including fasting, 1-h and 2-h glucose measurements between their 24th and 28th gestational weeks. Pregnancy outcomes were transcribed from medical registries. GDM was defined according to WHO criteria (fasting: ≥126 mg/dL; 2-h value: ≥140 mg/dL) and macrosomia as a birth weight equal to or higher than 4000 g. Areas under the receiver operator characteristic curve (AUC) were compared and diagnostic properties of various cut-off points were evaluated. The AUCs for the prediction of macrosomia were 0.606 (0.572-0.637) for the 1-h and 0.589 (0.557-0.622) for the 2-h plasma glucose test. Similar predictability was demonstrable regarding combined adverse outcomes: 0.582 (0.559-0.604) for the 1-h test and 0.572 (0.549-0.595) for the 2-h test. When the 1-h glucose test was evaluated against a diagnosis of GDM defined by the 2-h glucose test, the AUC was 0.903 (0.886-0.919). The cut-off point that maximized sensitivity (83%) and specificity (83%) was 141 mg/dL, identifying 21% of the women as positive. A cut-off point of 160 mg/dL, with lower sensitivity (62%), had higher specificity (94%), labeling 8.6% as positive. Detection of GDM can be done with a 1-h 75-g OGTT: the value of 160 mg/dL has the same diagnostic performance as the conventional 2-h value (140 mg/dL). The simplification of the test may improve coverage and timing of the diagnosis of GDM.