996 resultados para Systems tract


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with a finite element modelling method for thin layer mortared masonry systems. In this method, the mortar layers including the interfaces are represented using a zero thickness interface element and the masonry units are modelled using an elasto-plastic, damaging solid element. The interface element is formulated using two regimes; i) shear-tension and ii) shearcompression. In the shear-tension regime, the failure of joint is consiedered through an eliptical failure criteria and in shear-compression it is considered through Mohr Coulomb type failure criterion. An explicit integration scheme is used in an implicit finite element framework for the formulation of the interface element. The model is calibrated with an experimental dataset from thin layer mortared masonry prism subjected to uniaxial compression, a triplet subjected to shear loads a beam subjected to flexural loads and used to predict the response of thin layer mortared masonry wallettes under orthotropic loading. The model is found to simulate the behaviour of a thin layer mortated masonry shear wall tested under pre-compression and inplane shear quite adequately. The model is shown to reproduce the failure of masonry panels under uniform biaxial state of stresses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Substation Automation Systems have undergone many transformational changes triggered by improvements in technologies. Prior to the digital era, it made sense to confirm that the physical wiring matched the schematic design by meticulous and laborious point to point testing. In this way, human errors in either the design or the construction could be identified and fixed prior to entry into service. However, even though modern secondary systems today are largely computerised, we are still undertaking commissioning testing using the same philosophy as if each signal were hard wired. This is slow and tedious and doesn’t do justice to modern computer systems and software automation. One of the major architectural advantages of the IEC 61850 standard is that it “abstracts” the definition of data and services independently of any protocol allowing the mapping of them to any protocol that can meet the modelling and performance requirements. On this basis, any substation element can be defined using these common building blocks and are made available at the design, configuration and operational stages of the system. The primary advantage of accessing data using this methodology rather than the traditional position method (such as DNP 3.0) is that generic tools can be created to manipulate data. Self-describing data contains the information that these tools need to manipulate different data types correctly. More importantly, self-describing data makes the interface between programs robust and flexible. This paper proposes that the improved data definitions and methods for dealing with this data within a tightly bound and compliant IEC 61850 Substation Automation System could completely revolutionise the need to test systems when compared to traditional point to point methods. Using the outcomes of an undergraduate thesis project, we can demonstrate with some certainty that it is possible to automatically test the configuration of a protection relay by comparing the IEC 61850 configuration extracted from the relay against its SCL file for multiple relay vendors. The software tool provides a quick and automatic check that the data sets on a particular relay are correct according to its CID file, thus ensuring that no unexpected modifications are made at any stage of the commissioning process. This tool has been implemented in a Java programming environment using an open source IEC 61850 library to facilitate the server-client association with the relay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper details the design and performance assessment of a unique collision avoidance decision and control strategy for autonomous vision-based See and Avoid systems. The general approach revolves around re-positioning a collision object in the image using image-based visual servoing, without estimating range or time to collision. The decision strategy thus involves determining where to move the collision object, to induce a safe avoidance manuever, and when to cease the avoidance behaviour. These tasks are accomplished by exploiting human navigation models, spiral motion properties, expected image feature uncertainty and the rules of the air. The result is a simple threshold based system that can be tuned and statistically evaluated by extending performance assessment techniques derived for alerting systems. Our results demonstrate how autonomous vision-only See and Avoid systems may be designed under realistic problem constraints, and then evaluated in a manner consistent to aviation expectations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Government efforts to help our economy through the global financial crisis could be eroded by the future economic impacts of global warming. The good news is that a ‘factor five’ approach to productivity – delivering five times more value with the same input, or using one-fifth the resources to deliver the same value – will not only help cut greenhouse gas emissions but, done effectively, bring economic benefits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Melbourne-based manufacturer Muller Industries Australia’s new cooling system saves 80 per cent of the average water usage in commercial office buildings that use water-based cooling towers.