1000 resultados para Sironen, Esa
Resumo:
Kirjallisuusarvostelu
Resumo:
Kirjallisuusarvostelu
Resumo:
This master’s thesis has been done for Drive! –project in which a new electric motor solution for mobile working machines is developed. Generic simulation model will be used as marketing and development tool. It can be used to model a wide variety of different vehicles with and without electric motor and to show customer the difference between traditionally build vehicles and those with new electric motor solution. Customers can also use simulation model to research different solutions for their own vehicles. At the start of the project it was decided that MeVEA software would be used as main simulation program and Simulink will only be used to simulate the operation of electrical components. Development of the generic model started with the research of these two software applications, simulation models which are made with them and how these simulation models can be build faster. Best results were used for building of generic simulation model. Finished generic model can be used to produce new tractor models for real-time simulations in short notice. All information about model is collected to one datasheet which can be easily filled by the user. After datasheet is filled a script will automatically build new simulation model in seconds. At the moment generic model is capable of building simulation models for wide variety of different tractors but it can be easily altered for other vehicle types too which would also benefit greatly from electric drive solution. Those could be for example wheel loaders and harvesters.
Resumo:
Esitys Kansalliskirjaston järjestämässä Asiantuntijaseminaarissa Helsingissä 28.4.2015.
Resumo:
Recovery boilers are built all over the world. The roots of recovery technology are longer than the roots of recovery boilers. But it wasn’t until the invention of recovery boilers before the Second World War that the pulping technology was revolutionalized. This led to long development of essentially the same type of equipment, culminating into units that are largest biofuel boilers in the world. Early recovery technology concentrated on chemical recovery as chemicals cost money and if one could recycle these chemicals then the profitability of pulp manufacture would improve. For pulp mills the significance of electricity generation from the recovery boiler was for long secondary. The most important design criterion for the recovery boiler was a high availability. The electricity generation in recovery boiler process can be increased by elevated main steam pressure and temperature or by higher black liquor dry solids as well as improving its steam cycle. This has been done in the modern Scandinavian units.
Resumo:
Suomen metsäteollisuus elää voimakasta uusiutumis- ja murrosvaihetta, joka ilmenee muutoksina yksittäisten tehtaiden ja tehdasintegraattien toiminnassa. Monia yksikköjä on poistunut tuotannosta ja tuotannon painotusta on muutettu. Toisaalta metsäteollisuus on suuntaamassa uusille aloille, jolloin tuotteina voivat olla esimerkiksi erilaiset biopolttoaineet, kemianteollisuuden raaka-aineet ja uuden sukupolven paperi- ja kartonkituotteet. Metsäteollisuuden muuttuminen ja laitosten monimutkaistuminen sekä jatkuvasti lisääntyvä tiedontarve asettavat yhä suurempia vaatimuksia sekä toiminnanharjoittajien ympäristövastaaville että viranomaisille. Hallinnon jatkuva muutos ja niukkenevat voimavarat voivat johtaa siihen, että käytännön lupa- ja valvontatyöhön jää yhä vähemmän aikaa. Kaakkois-Suomen ELY-keskuksen koordinoima hanke ”Metsäteollisuuden ympäristöstrategia vuoteen 2020 - hallinnon näkökulma” pyrkii vastaamaan edellä mainittuihin haasteisiin strategiatyön avulla. Hankkeen tarkoituksena oli tarkastella metsäteollisuuden ympäristönäkökohtia niistä lähtökohdista, joihin yritys voi vaikuttaa raaka-aineen tulosta tehtaalle ja tuotteen lähdöstä tehtaalta sekä tehtaan perustamisesta sulkemiseen ja jälkihoitoon asti. Tavoitteena oli määritellä toiminnoille toimiva ympäristöstrategia. Strategiassa pyrittiin löytämään yhteisymmärrys toiminnanharjoittajan ja viranomaisen kanssa mm. siitä, miten otetaan käyttöön parhaat käytännöt niin teollisuudessa kuin hallinnossakin, toimitaan uusien BAT-, IED- ja vesienhoitoperiaatteiden mukaisesti sekä edistetään kestävän kehityksen mukaisten tuotteiden markkinoille tuloa ja otetaan ennakointi tavaksi -lähtökohta käyttöön kaikessa toiminnassa. Hanketyössä esille nousseet haasteet ryhmiteltiin aihelueittain kolmeksi pääkohdaksi tärkeysjärjestyksessä: viranomaisen ja teollisuuden tiedonkulun ja tietämyksen parantaminen, lupa-, valvonta- ja hallintoprosessien parantaminen sekä uusien haasteiden kartoittaminen ja niihin reagointi. Haasteiden ratkaisukeinoiksi etsittiin käytännön toimenpiteitä sekä määriteltiin niille vastuutahot. Toimenpiteiksi esitettiin mm. viranomaisen ja teollisuuden yhteisiä koulutuspäiviä, asiantuntijapaneelin perustamista sekä lupamääräysten antamista myös tehtaan tai tuotantoyksikön sulkemisen tai muuttamisen varalle. Riittävien resurssien ja tietotaidon turvaaminen niin hallinnossa kuin teollisuudessa on ehdoton edellytys toimenpiteiden onnistumiselle
Resumo:
Fluid handling systems such as pump and fan systems are found to have a significant potential for energy efficiency improvements. To deliver the energy saving potential, there is a need for easily implementable methods to monitor the system output. This is because information is needed to identify inefficient operation of the fluid handling system and to control the output of the pumping system according to process needs. Model-based pump or fan monitoring methods implemented in variable speed drives have proven to be able to give information on the system output without additional metering; however, the current model-based methods may not be usable or sufficiently accurate in the whole operation range of the fluid handling device. To apply model-based system monitoring in a wider selection of systems and to improve the accuracy of the monitoring, this paper proposes a new method for pump and fan output monitoring with variable-speed drives. The method uses a combination of already known operating point estimation methods. Laboratory measurements are used to verify the benefits and applicability of the improved estimation method, and the new method is compared with five previously introduced model-based estimation methods. According to the laboratory measurements, the new estimation method is the most accurate and reliable of the model-based estimation methods.
Resumo:
This book was created as postgraduate lecture notes for Lappeenranta University of Technology's special course of steam power plants. But as with anything ever written the ideas shown have nurtured for a long time. Parts of these chapters have appeared elsewhere as individual papers or work documents. One of the most helpful episodes have been presentations and discussions during Pohto Operator training seminars. Input from those sessions can be seen in chapter firing. You who run recovery boilers, I salute you. The purpose of this text is to give the reader an overview of recovery boiler operation. Most parts of the recovery boiler operation are common to boilers burning other fuels. The furnace operation differs significantly from operation of other boiler furnaces. Oxygen rich atmosphere is needed to burn fuel efficiently. But the main function of recovery boiler is to reduce spent cooking chemicals. Reduction reactions happen best in oxygen deficient atmosphere. This dual, conflicting nature of recovery furnace makes understanding it so challenging. To understand the processes happening in the recovery furnace one must try to understand the detailed processes that might occur and their limitations. Therefore chapters on materials, corrosion and fouling have been added.
Resumo:
Cantidades variables de dos sistemas multienzimáticos de tripsina-quimotripsina-peptidasa y pepsina-pancreatina, fueron utilizados para evaluar el efecto de los taninos provenientes de frijol Carioca (Phaseolus vulgaris L.) sobre la digestibilidad de la faseolina, en las formas nativa y denaturalizada. Esta evaluación hecha por los métodos de caida de pH, de hidrólisis en medio tamponado con posterior medición del grado de hidrólisis con ninhidrina y por la técnica electroforética, demostró el efecto adverso de los taninos condensados sobre la digestibilidad de la faseolina, después de producirse una significativa inhibición en el grado de hidrólisis de esa proteína por los dos sistemas multienzimáticos. Se comprobó la dificultad de hidrólisis de la faseolina cuando esta unida al tanino en el punto de saturación (proporción 5/20 tanino/proteína p/p y mayores), después de detectarse en los perfiles electroforéticos, péptidos de 45.7 y 24KDa, resistentes a la hidrólisis hasta por prolongados períodos de incubación. Esto se debió a la existencia de un complejo de naturaleza refractária no digeríble, incluso en condiciones excesivas de enzima. Los resultados sugieren la unión simultánea del tanino con mas de un ligante a través de sus múltiples grupos hidróxilos libres, formando un complejo proteína-tanino-enzima (PTE)* que correspondería a la fracción no digeríble de la faseolina.
Resumo:
This thesis studies energy efficiencies and technical properties of gas driven ground source heat pumps and pump systems. The research focuses on two technologies: gas engine driven compressor heat pump and thermally driven gas absorption heat pump. System consist of a gas driven compressor or absorption ground source heat pump and a gas condensing boiler, which covers peak load. The reference system is a standard electrically powered compressor heat pump with electric heating elements for peak load. The systems are compared through primary energy ratios. Coefficient of performances of different heat pump technologies are also compared. At heat pump level, gas driven heat pumps are having lower coefficient of performances as compared with corresponding electric driven heat pump. However, gas heat pumps are competitive when primary energy ratios, where electricity production losses are counted in, are compared. Technically, gas heat pumps can potentially achieve a slightly higher temperatures with greater total energy efficiency as compared to the electric driven heat pump. The primary energy ratios of gas heat pump systems in relation to EHP-system improves when the share of peak load increases. Electric heat pump system's overall energy efficiency is heavily dependent on the electricity production efficiency. Economy as well as CO2-emissions were not examined in this thesis, which however, would be good topics for further study.