998 resultados para OPTIC RADIATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photodegradation is considered to be one of the most important processes of elimination of pharmaceutical drugs from natural water matrices. The high consumption and discharge of these substances, in particular antidepressants, to the aquatic environment supports the need to study degradation processes. This dissertation aimed at studying the direct and indirect photodegradation of sertraline, an antidepressant known for its persistence in the environment, and the evaluation of the influence of environmentally relevant factors in its photodegradation. The photodegradation experiments were developed under simulated solar light and the irradiation times converted to summer sunny days (SSD), an equivalent time in natural environmental conditions. The direct photodegradation was evaluated in solutions of sertraline prepared in ultrapure water and the indirect photodegradation was studied through the addition of photosensitizers (humic substances, Fe(III), nitrates and oxygen). Further irradiation studies were perfomed in aqueous samples collected from two wastewater treatment plants, Vouga river and Ria de Aveiro. The samples were chemically characterized (dissolved organic carbon, nitrates and nitrites and iron determination and UV/Vis spectroscopy). The quantification of sertraline was done by HPLC-UV and photoproducts from direct photodegradation were identified by electrospray mass spectrometry. An observed direct photodegradation rate of sertraline of 0.0062 h-1 was determined, corresponding to a half-life time of 111 h (equivalent to 29 SSD). A significant influence of photosensitizers was observed, the best results being achieved in irradiations of sertraline with humic acids, obtaining a half-life time of 12 h. This was attributed to the hydrophobicity of this substance and higher absortivity in the UV/Vis wavelength, which promote processes of indirect photodegradation. The degradation of sertraline in natural samples was also enhanced comparatively to the direct photodegradation, achieving half-life times between 10 and 25h; the best results were achieved in samples from the primary treatment of a wastewater treatment plant and Ria de Aveiro, with half-life times of 10 and 16 h, respectively. A total of six photoproducts formed during the direct photodegradation of sertraline were identified, three of which were not yet identified in the literature. The main factors contributing to the degradation of sertraline were analysed but this was not fully accomplished, requiring further studies of the composition of the natural matrices and the combined influence of distinct photosensitizers during the irradiation. Nevertheless, it was concluded that the photodegradation of sertraline is greatly influenced by indirect photodegradation processes, promoted by the presence of photosensitizers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To obtain and analyse patient´s knowledge and perceptions regarding radiation exposure, from both natural and man-made radiation of medical procedures and interventions. Verify if patients worry about their exposure when undergoing medical exams, are aware of associated risks and means of radiological protection and if their knowledge on medical radiation exposure affects their own decisions. Methods and Materials: On a medical environment a self-applied questionnaire was used as instrument and assigned to patients who would undergo medical imaging exams involving ionising radiation. A total of 300 valid questionnaires were interpreted and statistically analysed through descriptive statistics and Phi & Cramer´s V correlation tests. Results: 44.3% of patients believe most of their exposure derives from electronic appliances and 25% from medical imaging exams, while patient´s with higher education levels tend to consider is comes from the environment. The great majority of patients (95%) consider that only certified personnel should operate medical imaging equipment, but 74% never ask for their qualifications. 66.3% of patients claim that Technologists have more education on radiological protection and about 60% of patients rarely or never worry about radiation exposure when undergoing medical imaging exams. Conclusion: Patients overestimate the risks of industrial radiation exposure while they underestimate the associated risks of medical radiation exposure and the Technologist´s ability to reduce the inherent radiation exposure of medical imaging exams. Patient´s knowledge on radiation and radiological protection is based more on perceptions and beliefs, rather than factual knowledge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, Artificial Neural Networks are applied to multistep long term solar radiation prediction. The networks are trained as one-step-ahead predictors and iterated over time to obtain multi-step longer term predictions. Auto-regressive and Auto-regressive with exogenous inputs solar radiationmodels are compared, considering cloudiness indices as inputs in the latter case. These indices are obtained through pixel classification of ground-to-sky images. The input-output structure of the neural network models is selected using evolutionary computation methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Engenharia Biomédica e Biofísica, Universidade de Lisboa, Faculdade de Ciências, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have implemented the WRF-Chem model version 3.5 over Poland to quantify the direct and indirect feedback effects of aerosols on simulated meteorology and aerosol concentrations. Observations were compared with results from three simulations at high spatial resolutions of 5 × 5 km: (1) BASE—without any aerosol feedback effects; (2) DIR—with direct aerosol-radiative effects (3) INDIR—with direct and indirect aerosol-radiative effects. We study the overall effect during January 2011 as well as selected episodes of the highest differences in PM10 concentrations between the three simulations. For the DIR simulation, the decrease in monthly mean incoming solar radiation (SWDOWN) appears for the entire study area. It changes geographically, from about −8.0 to −2.0 W m−2, respectively for the southern and northern parts of the country. The highest changes do not correspond to the highest PM10 concentration. Due to the solar radiation changes, the surface mean monthly temperature (T2) decreases for 96 % of the area of Poland, but not more than 1.0 °C. Monthly mean PBLH changes by more than ±5 m for 53 % of the domain. Locally the differences in PBLH between the DIR and BASE are higher than ± 20 m. Due to the direct effect, for 84 % of the domain, the mean monthly PM10 concentrations increase by up to 1.9 µg m−3. For the INDIR simulation the spatial distribution of changes in incoming solar radiation as well as air temperature is similar to the DIR simulation. The decrease of SWDOWN is noticed for the entire domain and for 23 % of the domain is higher than −5.0 W m−2. The absolute differences of PBLH are slightly higher for INDIR than DIR but similarly distributed spatially. For daily episodes, the differences between the simulations are higher, both for meteorology and PM10 concentrations, and the pattern of changes is usually more complex. The results indicate the potential importance of the aerosol feedback effects on modelled meteorology and PM10 concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The big proliferation of mobile communication systems has caused an increased concern about the interaction between the human body and the antennas of mobile handsets. In order to study the problem, a multiband antenna was designed, fabricated and measured to operate over two frequency sub bands 900 and 1800 MHz. After that, we simulated the same antenna, but now, in the presence of a human head model to analyze the head's influence. First, the influence of the human head on the radiation efficiency of the antenna has been investigated as a function of the distance between the head and the antenna and with the inclination of the antenna. Furthermore, the relative amount of the electromagnetic power absorbed in the head has been obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The big proliferation of mobile communication systems has caused an increased concern about the interaction between the human body and the antennas of mobile handsets. In order to study the problem, a multiband antenna was designed, fabricated and measured to operate over two frequency sub bands 900 and 1800 MHz. After that, we simulated the same antenna, but now, in the presence of a human head model to analyze the head's influence. First, the influence of the human head on the radiation efficiency of the antenna has been investigated as a function of the distance between the head and the antenna and with the inclination of the antenna. Furthermore, the relative amount of the electromagnetic power absorbed in the head has been obtained. In this study the electromagnetic analysis has been performed via FDTD (Finite Difference Time Domain).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To increase the amount of logic available in SRAM-based FPGAs manufacturers are using nanometric technologies to boost logic density and reduce prices. However, nanometric scales are highly vulnerable to radiation-induced faults that affect values stored in memory cells. Since the functional definition of FPGAs relies on memory cells, they become highly prone to this type of faults. Fault tolerant implementations, based on triple modular redundancy (TMR) infrastructures, help to keep the correct operation of the circuit. However, TMR is not sufficient to guarantee the safe operation of a circuit. Other issues like the effects of multi-bit upsets (MBU) or fault accumulation, have also to be addressed. Furthermore, in case of a fault occurrence the correct operation of the affected module must be restored and the current state of the circuit coherently re-established. A solution that enables the autonomous correct restoration of the functional definition of the affected module, avoiding fault accumulation, re-establishing the correct circuit state in realtime, while keeping the normal operation of the circuit, is presented in this paper.