998 resultados para Nuclear radiation.
Resumo:
We present the case of a 45-year-old woman with a history of multiple back surgeries to illustrate the feasibility of combining CT myelography (myeloCT) and Tc-HDP SPECT/CT bone scan in a 1-step procedure to realize a combined SPECT-myeloCT. Myelography CT and SPECT/CT were required to assess nerve root compression and pseudarthrosis, respectively. The proposed combined acquisition protocol provides information about nervous compression as well as pseudarthrosis in a 1 examination, optimizing radiation dose and patient comfort.
Resumo:
OBJETIVO: Este trabalho avaliou doses recebidas por acompanhantes que compartilharam o mesmo quarto terapêutico com pacientes tratados com câncer de tireóide ingerindo iodo-131 (131I) e comparou os resultados obtidos aos limites determinados pelas normas brasileiras de radioproteção. MATERIAIS E MÉTODOS: Avaliaram-se seis grupos de pessoas. Cada grupo foi formado por um acompanhante e um paciente, que compartilharam o mesmo quarto terapêutico. Realizaram-se, também, 23 outros experimentos, sendo que nestes um simulador foi usado em substituição à segunda pessoa no quarto terapêutico. As atividades de 131I administradas aos pacientes foram de 3.700 MBq ou 5.550 MBq. Dosímetros termoluminescentes na forma de pó, fluoreto de lítio dopado com magnésio, titânio e sódio foram usados para a avaliação das doses. RESULTADOS: Os resultados mostraram que uma pessoa que compartilha o mesmo quarto terapêutico, durante dois dias, com um paciente tratado com 3.700 MBq ou 5.550 MBq de 131I, seguindo as orientações de radioproteção fornecidas pela equipe médica, é exposta a uma dose média de (0,51 ± 0,02) mSv, para um nível de confiança de 99%. CONCLUSÃO: De acordo com as normas brasileiras, do ponto de vista da radioproteção, não há impedimento acompanhar um paciente de medicina nuclear durante esse tratamento.
Resumo:
OBJETIVO: Realizar levantamento sobre quais testes de controle de qualidade são realizados nos calibradores de dose dos serviços de medicina nuclear da cidade de São Paulo, SP. Estudar a exatidão das medições de atividade de sete calibradores de dose no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares, usando fontes de radionuclídeos importantes clinicamente. MATERIAIS E MÉTODOS: O levantamento sobre o controle de qualidade foi realizado a partir de questionários enviados aos serviços. Foram utilizados, no estudo de exatidão dos sete calibradores de dose, fontes de Ga-67, Tc-99m e Tl-201 e um instrumento padrão secundário. RESULTADOS: Os resultados do levantamento sobre os testes de controle de qualidade mostraram algumas impropriedades, por exemplo, a falta da realização diária do teste de reprodutibilidade por todos os serviços. Os resultados do teste de exatidão para os sete calibradores de dose estudados mostraram-se dentro do limite de aceitação da norma nacional (±10%). CONCLUSÃO: A situação com relação ao controle de qualidade de calibradores de dose é insatisfatória, de acordo com o pequeno número de serviços que participaram do levantamento. O estudo da exatidão em sete calibradores de dose não indicou falhas de desempenho e estabeleceu uma calibração desses instrumentos para as fontes utilizadas.
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
Law 15/2012 established in Spain four new environmental taxes and extended the scope objective excise duties on mineral oils to tax the use of natural gas and coal as sources of electricity. One of the newly created taxes falls on all electric power producers, and has as tax base the turnover. The second one tax hydropower production, and the other two fall on the nuclear industry. So, there are two new taxes in Spain on the production of electricity from nuclear sources. The first one is a tax on nuclear waste production; the second one is a tax on the storage of nuclear waste. However, these are not the only levies in the Spanish tax system affecting nuclear waste. At the State level there are already several charges on nuclear waste. At the regional level, on the other hand, two Autonomous Communities were taxing nuclear waste. The creation of these new State taxes will finish with the regional taxes, but the State will be oblige to compensate these regions for losing revenues. The purpose of this work is to carry out a critical analysis of the Spanish system of taxation on nuclear waste.
Resumo:
In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.
Resumo:
Background: Myotragus balearicus was an endemic bovid from the Balearic Islands (Western Mediterranean) that became extinct around 6,000-4,000 years ago. The Myotragus evolutionary lineage became isolated in the islands most probably at the end of the Messinian crisis, when the desiccation of the Mediterranean ended, in a geological date established at 5.35 Mya. Thus, the sequences of Myotragus could be very valuable for calibrating the mammalian mitochondrial DNA clock and, in particular, the tree of the Caprinae subfamily, to which Myotragus belongs. Results: We have retrieved the complete mitochondrial cytochrome b gene (1,143 base pairs), plus fragments of the mitochondrial 12S gene and the nuclear 28S rDNA multi-copy gene from a well preserved Myotragus subfossil bone. The best resolved phylogenetic trees, obtained with the cytochrome b gene, placed Myotragus in a position basal to the Ovis group. Using the calibration provided by the isolation of Balearic Islands, we calculated that the initial radiation of caprines can be dated at 6.2 ± 0.4 Mya. In addition, alpine and southern chamois, considered until recently the same species, split around 1.6 ± 0.3 Mya, indicating that the two chamois species have been separated much longer than previously thought. Conclusion: Since there are almost no extant endemic mammals in Mediterranean islands, the sequence of the extinct Balearic endemic Myotragus has been crucial for allowing us to use the Messinian crisis calibration point for dating the caprines phylogenetic tree.