1000 resultados para Multiple diffraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advances made over the past decade in structure determination from powder diffraction data are reviewed with particular emphasis on algorithmic developments and the successes and limitations of the technique. While global optimization methods have been successful in the solution of molecular crystal structures, new methods are required to make the solution of inorganic crystal structures more routine. The use of complementary techniques such as NMR to assist structure solution is discussed and the potential for the combined use of X-ray and neutron diffraction data for structure verification is explored. Structures that have proved difficult to solve from powder diffraction data are reviewed and the limitations of structure determination from powder diffraction data are discussed. Furthermore, the prospects of solving small protein crystal structures over the next decade are assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simulated annealing approach to structure solution from powder diffraction data, as implemented in the DASH program, is easily amenable to parallelization at the individual run level. Very large scale increases in speed of execution can therefore be achieved by distributing individual DASH runs over a network of computers. The GDASH program achieves this by packaging DASH in a form that enables it to run under the Univa UD Grid MP system, which harnesses networks of existing computing resources to perform calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simulated annealing approach to structure solution from powder diffraction data, as implemented in the DASH program, is easily amenable to parallelization at the individual run level. Modest increases in speed of execution can therefore be achieved by executing individual DASH runs on the individual cores of CPUs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Fazzan Basin of south-west Libya is at present arid with less than 20 mm of rainfall per annum. However, regionally extensive limestones, lacustrine sands and coquina (fossiliferous carbonate rock) deposits show that the Fazzan Basin previously contained a large palaeolake, indicating that the climate in the past was more humid. Optically stimulated luminescence (OSL) dating techniques have been applied to key lacustrine deposits within the basin in an attempt to provide an internally consistent chronology for this humidity record. Results indicate that palaeolake sediments within the Fazzan Basin record a very long history of palacohydrological change, ranging from present day and conditions to humidity capable of sustaining a lake with an approximate area of 76,250 km(2). The existence of humid periods in mid oxygen isotope stage 5 and the early Holocene is confirmed. An older lacustrine event, tentatively correlated to oxygen isotope stage 11, is also recognized. In addition, evidence is presented for at least two humid phases beyond the age range over which the conventional OSL dating technique is applicable. This study demonstrates that OSL dating of palaeolake sediments within the Fazzan Basin offers the potential to provide a detailed record of North African humidity spanning several glacial-interglacial cycles. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mortality (7 and 14 d), weight change (7 and 14 d), and metal uptake of Eisenia fetida (Savigny, 1826) kept in Pb(NO3)(2)-treated Kettering loam soil in single- and multiple-occupancy (10 earthworms) test containers were determined. The number of earthworms to dry mass (g) ratio of soil was 1:50 in both sets of test containers. Lead concentrations were in the nominal range of 0 to 10,000 mg Pb/kg soil (mg/kg hereafter). Levels of mortality at a given concentration were statistically identical between the single- and multiple-occupancy tests, except at 1,800 mg/kg, at which significantly (p less than or equal to 0.05) more mortality occurred in the multiple-occupancy tests. Death of individual earthworms in the multiple-occupancy tests did not trigger death of the other earthworms in that soil. The LC50 values (concentration statistically likely to kill 50% of the population) were identical between the multiple- and single-occupancy soils: 2,662 mg/kg (2,598-2,984, 7 d) and 2,589 mg/kg (2,251-3,013, 14 d) for the multiple-occupancy soils and 2,827 mg/kg (2,443-3,168, both 7 and 14 d) for the single-occupancy soils (values in brackets represent the 95% confidence intervals). Data were insufficient to calculate the concentration statistically likely to reduce individual earthworm mass by 50% (EC50), but after 14 d, the decrease in earthworm weight in the 1,800 and 3,000 mg/kg tests was significantly greater in the multiple- than in the single-occupancy soils. At 1,000, 1,800, and 3,000 mg/kg tests, earthworm Pb tissue concentration was significantly (p less than or equal to 0.05) greater in earthworms from the multiple-occupancy soils. The presence of earthworms increased the NH3 content of the soil; earthworm mortality increased NH3 concentrations further but not to toxic levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stable isotopic characterization of chlorine in chlorinated aliphatic pollution is potentially very valuable for risk assessment and monitoring remediation or natural attenuation. The approach has been underused because of the complexity of analysis and the time it takes. We have developed a new method that eliminates sample preparation. Gas chromatography produces individually eluted sample peaks for analysis. The He carrier gas is mixed with Ar and introduced directly into the torch of a multicollector ICPMS. The MC-ICPMS is run at a high mass resolution of >= 10 000 to eliminate interference of mass 37 ArH with Cl. The standardization approach is similar to that for continuous flow stable isotope analysis in which sample and reference materials are measured successively. We have measured PCE relative to a laboratory TCE standard mixed with the sample. Solvent samples of 200 nmol to 1.3 mu mol ( 24- 165 mu g of Cl) were measured. The PCE gave the same value relative to the TCE as measured by the conventional method with a precision of 0.12% ( 2 x standard error) but poorer precision for the smaller samples.