992 resultados para Metodo de Monte Carlo - Simulação por computador
Resumo:
BACKGROUND: Anal condylomata acuminata (ACA) are caused by human papilloma virus (HPV) infection which is transmitted by close physical and sexual contact. The result of surgical treatment of ACA has an overall success rate of 71% to 93%, with a recurrence rate between 4% and 29%. The aim of this study was to assess a possible association between HPV type and ACA recurrence after surgical treatment. METHODS: We performed a retrospective analysis of 140 consecutive patients who underwent surgery for ACA from January 1990 to December 2005 at our tertiary University Hospital. We confirmed ACA by histopathological analysis and determined the HPV typing using the polymerase chain reaction. Patients gave consent for HPV testing and completed a questionnaire. We looked at the association of ACA, HPV typing, and HIV disease. We used chi, the Monte Carlo simulation, and Wilcoxon tests for statistical analysis. RESULTS: Among the 140 patients (123 M/17 F), HPV 6 and 11 were the most frequently encountered viruses (51% and 28%, respectively). Recurrence occurred in 35 (25%) patients. HPV 11 was present in 19 (41%) of these recurrences, which is statistically significant, when compared with other HPVs. There was no significant difference between recurrence rates in the 33 (24%) HIV-positive and the HIV-negative patients. CONCLUSIONS: HPV 11 is associated with higher recurrence rate of ACA. This makes routine clinical HPV typing questionable. Follow-up is required to identify recurrence and to treat it early, especially if HPV 11 has been identified.
Resumo:
A joint project between the Paul Scherrer Institut (PSI) and the Institute of Radiation Physics was initiated to characterise the PSI whole body counter in detail through measurements and Monte Carlo simulation. Accurate knowledge of the detector geometry is essential for reliable simulations of human body phantoms filled with known activity concentrations. Unfortunately, the technical drawings provided by the manufacturer are often not detailed enough and sometimes the specifications do not agree with the actual set-up. Therefore, the exact detector geometry and the position of the detector crystal inside the housing were determined through radiographic images. X-rays were used to analyse the structure of the detector, and (60)Co radiography was employed to measure the core of the germanium crystal. Moreover, the precise axial alignment of the detector within its housing was determined through a series of radiographic images with different incident angles. The hence obtained information enables us to optimise the Monte Carlo geometry model and to perform much more accurate and reliable simulations.