992 resultados para Low impedance
Resumo:
OBJECTIVE: To study the benefits of a low-dose stimulation (LDS) protocol with purified urinary follicle-stimulating hormone in patients with polycystic ovaries who have presented previously with a very high ovarian response to a standard hMG stimulation. DESIGN: Cohort study. SETTING: Fertility center in a university hospital. PATIENT(S): Sixty-one patients involved in an IVF/ICSI program from January 1995 to December 1996. INTERVENTION(S): The patients were first stimulated with a standard protocol using hMG and presented with a very high ovarian response. These patients were then stimulated a second time using a low-dose protocol. Cryopreserved embryos were transferred in later artificial or natural cycles until to December 1999. MAIN OUTCOME MEASURE(S): Number of gonadotropin ampules; estradiol level on the day of ovulation induction; follicles, oocytes, and cryopreserved zygotes; fertilization, implantation, and pregnancy rates; and number of ovarian hyperstimulation syndromes (OHSS). RESULT(S): The number of ampules used, the estradiol level reached, and the number of oocytes obtained were significantly lower under the LDS than the standard protocol. High implantation (21.8%) and clinical pregnancy (38.4%) rates were obtained after LDS. The cumulated deliveries per cycle started and per patient were, respectively, 41.6% and 52.5%. Five patients suffered OHSS with the standard protocol, and none with the LDS. CONCLUSION(S): The LDS protocol offers a safe and efficient treatment for patients who present with echographic polycystic ovaries and are at risk of an excessive ovarian response to standard IVF stimulation protocols.
Resumo:
OBJECTIVE: To evaluate the relationship between changes in body bioelectrical impedance (BI) at 0.5, 50 and kHz and the changes in body weight, as an index of total body water changes, in acutely ill surgical patients during the rapid infusion of isotonic saline solution. DESIGN: Prospective clinical study. SETTING: Multidisciplinary surgical ICU in a university hospital. PATIENTS: Twelve male patients treated for acute surgical illness (multiple trauma n = 5, major surgery n = 7). Selection criteria: stable cardiovascular parameters, normal cardiac function, signs of hypovolemia (CVP < or = 5 mmHg, urine output < 1 ml/kg x h). INTERVENTIONS: After baseline measurements, a 60 min fluid challenge test was performed with normal saline solution, 0.25 ml/kg/min [corrected]. MEASUREMENTS AND RESULTS: Body weight (platform digital scale), total body impedance (four-surface electrode technique; measurements at 0.5, 50 and 100 kHz) and urine output. Fluid retention induced a progressive decrease in BI at 0.5, 50 and 100 kHz, but the changes were significant for BI 0.5 and BI 100 only, from 40 min after the beginning of the fluid therapy onwards. There was a significant negative correlation between changes in water retention and BI 0.5, with individual correlation coefficients ranging from -0.72 to 0.95 (p < 0.01-0.0001). The slopes of the regression lines indicated that for each kg of water change, there was a mean decrease in BI of 18 ohm, but a substantial inter-individual variability was noted. CONCLUSION: BI measured at low frequency can represent a valuable index of acute changes in body water in a group of surgical patients but not in a given individual.