997 resultados para Eucanaã Ferraz
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The WWγ triple gauge boson coupling parameters are studied using pp̄rarr; νγ+X(=e,μ) events at s=1.96 TeV. The data were collected with the D0 detector from an integrated luminosity of 162pb-1 delivered by the Fermilab Tevatron Collider. The cross section times branching fraction for pp̄→W(γ)+X→ νγ+X with ETγ>8 GeV and ΔR γ> 0.7 is 14.8±1.6(stat)±1.0(syst) ±1.0(lum)pb. The one-dimensional 95% confidence level limits on anomalous couplings are -0.88<Δκγ<0.96 and -0. 20<λγ<0.20. © 2005 The American Physical Society.
Resumo:
We present a measurement of the top quark pair (tt̄) production cross section in pp̄ collisions at √s=1.96 TeV using events with two charged leptons in the final state. This analysis utilizes an integrated luminosity of 224-243 pb-1 collected with the DØ detector at the Fermilab Tevatron Collider. We observe 13 events in the e+e -, eμ and μ+μ- channels with an expected background of 3.2±0.7 events. For a top quark mass of 175 GeV, we measure a tt̄ production cross section of σtt̄=8. 6-2.7 +3.2(stat)±1.1(syst)±0.6(lumi) pb, consistent with the standard model prediction. © 2005 Elsevier B.V. All rights reserved.
Resumo:
IEEE 1451 Standard is intended to address the smart transducer interfacing problematic in network environments. Usually, proprietary hardware and software is a very efficient solution to in planent the IEEE 1451 normative, although can be expensive and inflexible. In contrast, the use of open and standardized tools for implementing the IEEE 1451 normative is proposed in this paper. Tools such as Java and Phyton programming languages, Linux, programmable logic technology, Personal Computer resources and Ethernet architecture were integrated in order to constructa network node based on the IEEE 1451 standards. The node can be applied in systems based on the client-server communication model The evaluation of the employed tools and expermental results are presented. © 2005 IEEE.
Resumo:
Aim: To evaluate anti-Müllerian hormone (AMH) levels in patients with clinical and molecular diagnosis of 5α-reductase 2 deficiency. Patients and methods: Data from 14 patients whose age ranged from 21 days to 29 years were analyzed according to age and pubertal stage. Sexual ambiguity was rated as Prader III in 11 patients. LH, FSH, testosterone (T), dihydrotestosterone (DHT) and AMH serum levels were measured in all but two patients, who had been previously submitted to gonadectomy; T and DHT were also measured in 20 age-matched controls. Results: Gonadotropin levels were normal in all but one patient who retained gonads (six of whom had reached puberty) and T/DHT ratio was elevated in all patients when compared to controls. All prepubertal patients had AMH levels < -1 SD for age, while most pubertal patients had AMH levels compatible with pubertal stage. Conclusions: Prepubertal patients with 5α-reductase 2 deficiency have AMH values in the lower part of the normal range. These data indicate that T does not need to be converted to DHT to inhibit AMH secretion by Sertoli cells. © Freund Publishing House Ltd., London.
Resumo:
The aim of the present study was to investigate the effect of long-term oral supplementation of creatine on the physiological responses to aerobic training. Twelve purebred Arabian horses were submitted to aerobic training for 90 days, with and without creatine supplementation which consisted of the daily administration of 75g of creatine monohydrate mixed into the ration for 90 days of training. Physical conditioning was conducted on a high performance treadmill and training intensity was stipulated by calculating the V 4 (velocity at which blood lactate reaches 4mmol L -1) determined monthly for each animal. The individual intensity of physical force at 80% of aerobic threshold was established. An incremental exercise test was used to set the individual V4. After a warm up period of 4 min at 4m s -1), the speed was increased at 2min intervals to 6, 8 and 10m s -1). The blood samples were collected 15s before the end of each step to determine the concentration of lactate, packed cell volume, hemoglobin and red cell values. The results demonstrated a significant increase (P<0.05) in V4 in the groups that received creatine supplementation for 60 days or more when compared to the animals without creatine supplememntation. The other hematological variables were similar to all groups. The results showed that the prolonged creatine supplementation may have a beneficial al effect on the equine athletic performance.