1000 resultados para E. Ray Swan
Resumo:
HINDI
Resumo:
A microscopic theory is presented for the photoacoustic effect induced in solids by x-ray absorption. The photoacoustic effect results from the thermalization of the excited Auger electrons and photoelectrons. We explain the dependence of the photoacoustic signal S on photon energy and the proportionality to the x-ray absorption coefficient in agreement with recent experiments on Cu. Results are presented for the dependence of S on photon energy, sample thickness, and the electronic structure of the absorbing solid.
Resumo:
We discuss the possibility of identifying superheavy elements from the observation of their M-shell x-ray spectra, which might occur during the collision of a superheavy element with a heavy target. The same question is discussed for the possible observation of the x-rays from the quasimolecule (quasi-superheavy element) which is formed during such a heavy-ion collision. It is shown that it is very difficult, if not impossible, to determine any information about the interesting quantum electrodynamical effects from the M-shell x-ray spectra of these quasimolecules.
Resumo:
In the collision system Xe - Ag, the thresholds for excitation of quasimolecular L radiation and characteristic Ag L radiation have been found to lie at about 5 MeV and 1 MeV, respectively. These results are discussed on the basis of ab initio calculations of the screened interaction potential and the electron-correlation diagram.
Resumo:
Energies of muonic X-rays of the K-series of carbon, nitrogen and oxygen have been measured with an accuracy of about 15 eV. Root mean square radii of the nuclear charge distributions were deduced. The results 2.49±0.05 fm for carbon, 2.55 ±0.03 fm for nitrogen and 2.71 ±0.02 fm for oxygen are in good agreement at comparable accuracy with recent electron scattering data.
Resumo:
The registration of pre-operative volumetric datasets to intra- operative two-dimensional images provides an improved way of verifying patient position and medical instrument loca- tion. In applications from orthopedics to neurosurgery, it has a great value in maintaining up-to-date information about changes due to intervention. We propose a mutual information- based registration algorithm to establish the proper align- ment. For optimization purposes, we compare the perfor- mance of the non-gradient Powell method and two slightly di erent versions of a stochastic gradient ascent strategy: one using a sparsely sampled histogramming approach and the other Parzen windowing to carry out probability density approximation. Our main contribution lies in adopting the stochastic ap- proximation scheme successfully applied in 3D-3D registra- tion problems to the 2D-3D scenario, which obviates the need for the generation of full DRRs at each iteration of pose op- timization. This facilitates a considerable savings in compu- tation expense. We also introduce a new probability density estimator for image intensities via sparse histogramming, de- rive gradient estimates for the density measures required by the maximization procedure and introduce the framework for a multiresolution strategy to the problem. Registration results are presented on uoroscopy and CT datasets of a plastic pelvis and a real skull, and on a high-resolution CT- derived simulated dataset of a real skull, a plastic skull, a plastic pelvis and a plastic lumbar spine segment.
Resumo:
Background: Isometric grip strength, evaluated with a handgrip dynamometer, is a marker of current nutritional status and cardiometabolic risk and future morbidity and mortality. We present reference values for handgrip strength in healthy young Colombian adults (aged 18 to 29 years). Methods: The sample comprised 5.647 (2.330 men and 3.317 women) apparently healthy young university students (mean age, 20.6±2.7 years) attending public and private institutions in the cities of Bogota and Cali (Colombia). Handgrip strength was measured two times with a TKK analogue dynamometer in both hands and the highest value used in the analysis. Sex- and age-specific normative values for handgrip strength were calculated using the LMS method and expressed as tabulated percentiles from 3 to 97 and as smoothed centile curves (P3, P10, P25, P50, P75, P90 and P97). Results: Mean values for right and left handgrip strength were 38.1±8.9 and 35.9±8.6 kg for men, and 25.1±8.7 and 23.3±8.2 kg for women, respectively. Handgrip strength increased with age in both sexes and was significantly higher in men in all age categories. The results were generally more homogeneous amongst men than women. Conclusions: Sex- and age-specific handgrip strength normative values among healthy young Colombian adults are defined. This information may be helpful in future studies of secular trends in handgrip strength and to identify clinically relevant cut points for poor nutritional and elevated cardiometabolic risk in a Latin American population. Evidence of decline in handgrip strength before the end of the third decade is of concern and warrants further investigation
Resumo:
Resumen en catalán