993 resultados para Document Model


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: Vascular endothelial growth factor (VEGF) is known to increase vascular permeability and promote angiogenesis. It is expressed in most types of pleural effusions. However, the exact role of VEGF in the development of pleural effusions has yet to be determined. The anti-VEGF mAb, bevacizumab, has been used in the treatment of cancer to reduce local angiogenesis and tumour progression. This study describes the acute effects of VEGF blockade on the expression of inflammatory cytokines and pleural fluid accumulation. Methods: One hundred and twelve New Zealand rabbits received intrapleural injections of either talc or silver nitrate. In each group, half the animals received an intravenous injection of bevacizumab, 30 min before the intrapleural agent was administered. Five animals from each subgroup were sacrificed 1, 2, 3, 4 or 7 days after the procedure. Twelve rabbits were used to evaluate vascular permeability using Evans`s blue dye. Pleural fluid volume and cytokines were quantified. Results: Animals pretreated with anti-VEGF antibody showed significant reductions in pleural fluid volumes after talc or silver nitrate injection. IL-8 levels, vascular permeability and macroscopic pleural adhesion scores were also reduced in the groups that received bevacizumab. Conclusions: This study showed that bevacizumab interferes in the acute phase of pleural inflammation induced by silver nitrate or talc, reinforcing the role of VEGF as a key mediator in the production of pleural effusions. The results also suggest that bevacizumab should probably be avoided in patients requiring pleurodesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Noninvasive positive-pressure ventilation (NPPV) modes are currently available on bilevel and ICU ventilators. However, little data comparing the performance of the NPPV modes on these ventilators are available. Methods: In an experimental bench study, the ability of nine ICU ventilators to function in the presence of leaks was compared with a bilevel ventilator using the IngMar ASL5000 lung simulator (IngMar Medical; Pittsburgh, PA) set at a compliance of 60 mL/cm H(2)O, an inspiratory resistance of 10 cm H(2)O/L/s, an expiratory resistance of 20 cm H(2)O/L/s, and a respiratory rate of 15 breaths/min. All of the ventilators were set at 12 cm H(2)O pressure support and 5 cm H(2)O positive end-expiratory pressure. The data were collected at baseline and at three customized leaks. Main results: At baseline, all of the ventilators were able to deliver adequate tidal volumes, to maintain airway pressure, and to synchronize with the simulator, without missed efforts or auto-triggering. As the leak was increased, all of the ventilators (except the Vision [Respironics; Murrysville, PA] and Servo I [Maquet; Solna, Sweden]) needed adjustment of sensitivity or cycling criteria to maintain adequate ventilation, and some transitioned to backup ventilation. Significant differences in triggering and cycling were observed between the Servo I and the Vision ventilators. Conclusions: The Vision and Servo I were the only ventilators that required no adjustments as they adapted to increasing leaks. There were differences in performance between these two ventilators, although the clinical significance of these differences is unclear. Clinicians should be aware that in the presence of leaks, most ICU ventilators require adjustments to maintain an adequate tidal volume. (CHEST 2009; 136:448-456)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To develop an experimental model in rabbits to analyse the efficiency of extracorporeal shock wave therapy (ESWT) for Peyronie`s disease. We used 15 adult male rabbits divided into three equal groups. In group 1 (no penile ESWT) rabbits had three sessions of ESWT with 2000 shocks each (15 kV), but a rubber mat was placed between the shock head and rabbit to protect the penis; the rabbits were killed at 7 days after the last session of ESWT. In group 2 the rabbits had three sessions of ESWT using the same parameters, and were killed immediately after the last session to analyse the penis. In group 3 the rabbits had three sessions of ESWT as before but were killed at 7 days after the last session, and the penile tissue analysed macroscopically and histologically. The results showed clearly that the model was efficient, creating a similar situation to that when applying ESWT in the human penis. All of the rabbits in groups 2 and 3 had haematomas and diffuse petechiae after ESWT, and only four had urethral and penile bleeding. Almost all macroscopic changes disappeared after 48 h and only one rabbit in group 3 after 7 days had a haematoma on the dorsal penile surface. The histology (assessed using haematoxylin and eosin staining) of the cavernous body of the penis showed: unchanged histology in group 1; in group 2 there was a dilated and congested vascular space in the cavernous body, with interstitial extensive bleeding in the dermis; and in group 3 there was an increase in interstitial fibrous tissue in the cavernous septum, with deposition of collagen fibres and thickening of the tunica albuginea. The present model was efficient in producing tissue injury in the normal penis when treated with ESWT, suggesting that this promising model should be considered for use future studies of Peyronie`s disease.