994 resultados para Congenital aortic valve stenosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Coarctation of the aorta is a common congenital heart malformation. Mode of diagnosis changed from clinically to almost exclusively by echocardiogram and MRI. We claim to find a new echocardiographic index, based on simple and reliable morphologic measurements, to facilitate the diagnosis of aortic coarctation in the newborn.We reproduce the same procedure for older child to validate this new index. Material and Methods: We reviewed echocardiographic studies of 47 neonates with diagnosis of coarctation who underwent cardiac surgery between January 1997 and February 2003 and compared them with a matched control group. We measured 12 different sites of the aorta, aortic arch and the great vessels on the echocardiographic bands. In a second time we reviewed 23 infants for the same measurements and compare them with a matched control group. Results: 47 neonates with coarctation were analysed, age 11.8 _ 10 days,weight 3.0 _ 0.6 kg, body surface 0.20 _ 0.02m2. The control group was of 16 newborns aged 15.8 _ 10 days,weight 3.2 _ 0.9 kg and body surface 0.20 _ 0.04m2. A significant difference was noted in many morphologic measurement between the both groups, the most significant being the distance between the left carotid artery and the left subclavian artery (coarctation vs control: 7.3 _ 3mm vs 2.4 _ 0.8mm, p _ 0.0001). We then defined a new index, the carotid-subclavian arteries index (CSI) as the diameter of the distal tranverse aortic arch divided to the distance left carotid artery to left subclavian artery being also significaly different (coarctation vs control: 0.76 _ 0.86 vs 2.95 _ 1.24, p _ 0.0001). With the cutoff value of this index of 1.5 the sensitivity for aortic coarctation was 98% and the specificity of 92%. In an older group of infant with coarctation (16 patients) we apply the same principle and find for a cut-off value of 1.5 a sensitivity of 95% and a specificity of 100%. Conclusions: The CSI allows to evaluate newborns and infants for aortic coarctation with simple morphologic measurement that are not depending of the left ventricular function, presence of a patent ductus arteriosus or not. Further aggressive evaluation of these patient with a CSI _ 1.5 is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The expression of Staphylococcus aureus adhesins in Lactococcus lactis identified clumping factor A (ClfA) and fibronectin-binding protein A (FnBPA) as critical for valve colonization in rats with experimental endocarditis. This study further analyzed their role in disease evolution. Infected animals were followed for 3 d. ClfA-positive lactococci successfully colonized damaged valves, but were spontaneously eradicated over 48 h. In contrast, FnBPA-positive lactococci progressively increased bacterial titers in vegetations and spleens. At imaging, ClfA-positive lactococci were restricted to the vegetations, whereas FnBPA-positive lactococci also invaded the adjacent endothelium. This reflected the capacity of FnBPA to trigger cell internalization in vitro. Because FnBPA carries both fibrinogen- and fibronectin-binding domains, we tested the role of these functionalities by deleting the fibrinogen-binding domain of FnBPA and supplementing it with the fibrinogen-binding domain of ClfA in cis or in trans. Deletion of the fibrinogen-binding domain of FnBPA did not alter fibronectin binding and cell internalization in vitro. However, it totally abrogated valve infectivity in vivo. This ability was restored in cis by inserting the fibrinogen-binding domain of ClfA into truncated FnBPA, and in trans by coexpressing full-length ClfA and truncated FnBPA on two separate plasmids. Thus, fibrinogen and fibronectin binding could cooperate for S. aureus valve colonization and endothelial invasion in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study was performed to evaluate the prevalence of prenatal ultrasound diagnoses for renal anomalies in 20 registries of 12 European countries, and to compare the different prenatal scanning policies. Standardized data were acquired from 709,030 livebirths, stillbirths, and induced abortions during the study period of 2.5 years and transmitted for central analysis. At least one renal malformation was diagnosed in 1130 infants and fetuses. Prenatal diagnosis (PD) was given in 81.8% of all cases, 29% of these pregnancies were terminated. The highest detection rate was reported for unilateral multicystic dysplastic kidneys with 97% (102/105). An early diagnosis was documented for exstrophy of bladder at a mean gestational age of 18.5 weeks. Dilatations of the upper urinary tract were seen late in pregnancy at 28.3 weeks. Terminations of pregnancies (TOP) were performed in 67% (58/86) of the detected bilateral renal agenesis/dysgenesis, but only 4% of the unilateral multicystic dysplastic renal malformations (4/102). In about 1/3 of the cases, renal malformations are within the category of associated malformations, which include multiple non-syndromal malformations, chromosomal aberrations, and non-chromosomal syndromes. Renal malformations were detected in 2/3 of the associated category by the first prenatal ultrasound scan. Detection rates vary in the different countries of the European community due to diverse policies, ethical, and religious background. Countries with no routine ultrasound show the lowest rates in detection, and termination of pregnancy. Prenatally detected renal malformations should result in a careful examination for further anomalies. Prenatal ultrasound fulfills the needs of screening examinations and is a good tool in detecting lethal and severe renal malformations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To develop and compare two new technologies for diagnosing a contiguous gene syndrome, the Williams-Beuren syndrome (WBS). METHODS: The first proposed method, named paralogous sequence quantification (PSQ), is based on the use of paralogous sequences located on different chromosomes and quantification of specific mismatches present at these loci using pyrosequencing technology. The second exploits quantitative real time polymerase chain reaction (QPCR) to assess the relative quantity of an analysed locus. RESULTS: A correct and unambiguous diagnosis was obtained for 100% of the analysed samples with either technique (n = 165 and n = 155, respectively). These methods allowed the identification of two patients with atypical deletions in a cohort of 182 WBS patients. Both patients presented with mild facial anomalies, mild mental retardation with impaired visuospatial cognition, supravalvar aortic stenosis, and normal growth indices. These observations are consistent with the involvement of GTF2IRD1 or GTF2I in some of the WBS facial features. CONCLUSIONS: Both PSQ and QPCR are robust, easy to interpret, and simple to set up. They represent a competitive alternative for the diagnosis of segmental aneuploidies in clinical laboratories. They have advantages over fluorescence in situ hybridisation or microsatellites/SNP genotyping for detecting short segmental aneuploidies as the former is costly and labour intensive while the latter depends on the informativeness of the polymorphisms.