999 resultados para Comparativo
Resumo:
A comparative evaluation regarding a new zero-current-switching (ZCS) pulse width modulated (PWM) Sepic rectifier, operating in voltage step-down mode, employing two different techniques, in order to obtain high power factor and reduced total harmonic distortion (THD) at the input current, is presented. The methods are those in continuous-current mode operation, known as peak current mode control with slope compensation, and average-current mode control. The principle of operation, the theoretical analysis, a design example and the main experimental results are presented for both proposed control techniques.
Resumo:
BACKGROUND: Ultrasonography (US), Computed Tomography (CT), and Magnetic Resonance imaging (MR) were compared for the staging of renal tumors. The differences between these imaging techniques were also studied for their ability to detect adenopathies, vascular invasion, distant intra-abdominal metastases, and particularly adjacent organ invasion. METHODS: Thirty-one patients with solid or complex renal masses were prospectively studied using US, CT, and MR. Differences between the results obtained were studied using the COCHRAN G test and the McNEMAR test. The sensitivity and specificity of each diagnostic technique were compared against a gold standard of the surgical and histopathological findings. RESULTS: The following sensitivities were obtained: For the detection of adenopathy, US 63.6%, CT and MR 90.9%. For vascular invasion, US 42.8%, CT and MR 85.7%. For the adjacent organ invasion, US 28.5%, CT 85.7%, and MR 71.4%. Some of the criteria that suggest invasion of adjacent structures include: the envelopment of the adjacent structures by the tumor, tumor extension into the adjacent structures with an irregular appearance, and alterations in shape, size, and density of adjacent structures. Loss of fat planes between the tumor and adjacent structures is not a sign of tumor invasion. CONCLUSIONS: Significant differences were found in the detection capacity of US in relation to CT and MR, which were similar. All three techniques were highly sensitive and specific only in the detection of distant abdominal metastases. In addition to the accuracy of these diagnostic modalities for the detection and staging of tumors, invasiveness, risks and cost should be considered in relation to relative costs and benefits.
Resumo:
Grinding is a precision machining process which is widely used in the manufacture of components requiring fine tolerances and smooth surfaces. There are several imput parameters (cutting conditions, cutting fluid and grinding wheel type used, dressing conditions etc.) which can affect the process variables (tangential and normal cutting forces, roughness, grinding temperatures, G ratio, etc.) leading to differences in the roughness, in the surface integrity and in the mechanical strength of the ground component. Consequently, the imput parameters must be controlled in order to insure the workpiece final quality. This paper presents a comparative evaluation of the performance of two types of grinding wheels [a conventional (Al2O3) and a superabrasive (CBN)] when grinding a VC131 steel, by the analysis of specific process variables when varying the cutting conditions. Highest values of G ratio and lowest workpiece roughness was observed when using CBN grinding wheels. This confirms the global trend of replacement of alumina grinding wheels by CBN, when grinding DTG (difficult to grind) materials.
Resumo:
PURPOSE: To evaluate the therapeutic complications due to the use of immunosupressors in patients with nephropathy. METHODS: 76 patients who had used steroids and cyclophosphamide were retrospectively studied. The cases were divided into three groups: G1= 15 patients with Systemic Lupus Erythematosus without renal lesion; G2= 33 patients with lupus nephritis and G3= 28 patients with nephrotic syndrome owing to idiopathic glomerulopathy. RESULTS: There were no differences related to time of follow up (G1= 42.4 +/- 51, G2= 52.3 +/- 51, G3= 41.8 +/- 47.8 months), total used dosage of steroids (G1= 20, G2= 28, G3= 16 grams) and time of drug use (G1= 20, G2= 26, G3= 14.5 months). About cyclophosphamide use, there was no difference in the percentage of patients who used it (13% in G1, 51% in G2, 28% in G3), but the patients from G1 received lower total dosage than those from G2 (p<0.05). Cushingoid appearance, epigastric distress, psychiatric disorders, diabetes mellitus and ocular alterations occurred in all the three groups, with no statistically significant differences. The infections complications, those considered more severe clinically, were more frequent in G2 (G1= 6%, G2= 15%, G3= 0% - p<0.05), the same occurring with the deaths (7% in G1, 30% in G2, 0% in G3 - p<0.05). CONCLUSION: In patients with lupus nephritis there were more infections complications owing to prolonged immunosuppresion what may indicate a severity marker of this type of lesion.
Resumo:
BACKGROUND AND OBJECTIVES: Pressure controlled ventilation (PCV) is available in anesthesia machines, but there are no studies on its use during CO 2 pneumoperitoneum (CPP). This study aimed at evaluating pressure-controlled ventilation and hemodynamic and ventilatory changes during CPP, as compared to conventional volume controlled ventilation (VCV). METHODS: This study involved 16 dogs anesthetized with thiopental, fentanyl and pancuronium, which were randomly assigned to two groups: VC - volume controlled ventilation (n=8) and PC - pressure controlled ventilation (n=8). Hemodynamic and ventilatory parameters were monitored and recorded in 4 moments: M1 (before CPP), M2 (30 minutes after CPP = 10 mmHg), M3 (30 minutes after CPP=15 mmHg) and M4 (30 minutes after deflation). RESULTS: With CPP, there has been significant increase in tidal volume in PC group; there has been increase in airway pressures (peak and plateau), decrease in compliance with increase in CPP pressure, increase in heart rate, maintenance of mean blood pressure with higher values in the VC group in all stages; there was also increase in right atrium pressure with significant decrease after deflation, decrease in arterial pH with minor variations in PC group, greater arterial pCO 2 stability in PC group, and no significant changes in arterial pO 2. CONCLUSIONS: There were some differences in hemodynamic and ventilatory data between both ventilation control modes (VC and PC). It is possible to use pressure controlled ventilation during CPP, but the anesthesiologist must monitor and take a close look at alveolar ventilation, adjusting inspiratory pressure to ensure proper CO 2 elimination and oxygenation. © Sociedade Brasileira de Anestesiologia, 2005.
Resumo:
Purpose: to compare in a retrospective way, 51 women who underwent tubal ligation, 30 through microlaparoascopy (Gmicrol) and 21 through minilaparotomy (Gminil). Methods: the analyzed parameters were: total time for accomplishment of the procedure and the surgical technique, time of hospital stay and return to the habitual activities after the surgery, postoperative pain, morbidity, satisfaction degree and esthetic effect, considering values of p<0,05 as significant, and also standard cost. Results: Gmicrol took less time to accomplish the surgery than the Gminil (43 against 57 minutes respectively, p<0,05), less time to accomplish the surgical technique (6.48 against 30.32 minutes respectively, p<0,05), and lower hospital stay (9,90 hours as against 41,7 hours respectively, p <0,05). There was no significant difference between the two groups regarding time to return to the habitual activities after surgery. To evaluate postoperative pain, a scale of 0-10 it was applied. Gmicrol present a lower pain score on the 1st and 2nd postoperative days (1.13 and 0.26 to Gmicrol and 4.52 and 1.14 to Gminil, respectively, p<0,05). There was no significant difference between immediate postoperative the most common complaint being pain at the site of pain and that on the 3rd postoperative day. Gminil presented a higher morbidity rate incision. To evaluate the satisfaction degree and esthetic effect, numeric values were attributed to as good, regular, poor and very bad as answered by the patiets. Gmicrol presented a higher satisfaction degree (p<0,05) and better esthetic effect as compared to Gminil (p <0,05). The microlaparoscopy standard cost was R$ 109.30 being lower than that of minilaparotomy. Conclusions: tubal ligation by microlaparoscopy, under local anesthesia and conscious sedation presented some advantages compared to minilaparotomy.
Resumo:
As arterial hypertension can be diagnosed by different methods, among which are the traditional auscultatory instrument and the automated oscillometric monitor, the aim of this study was to compare the performance of these instruments, to evaluate the reliability of the digital oscillometer. The sample consisted of 40 patients under dental treatment, whose blood pressure measurements were recorded. The measurements of systolic and diastolic blood pressures were evaluated in terms of their intraclass correlation coefficients (r). For systolic blood pressure, an excellent level of agreement was found between the instruments, with r=0.93, and for diastolic blood pressure, there was a good level of agreement (r=0.75). It was concluded, from the excellent agreement for systolic blood pressure, that the oscillometric monitor can be recommended for the monitoring of the variations of that pressure in the same individual, while the good agreement obtained in the determination of the diastolic blood pressure indicates that the oscillometric method is reliable. However, new studies need to be carried out for a better understanding of the disagreements that can occur in the diastolic pressure results.
Resumo:
The genus Stryphnodendron (S.) belongs to the family Leguminosae, subfamily Mimosoideae, which includes mostly trees of tropical and subtropical South America. Extracts of the stem bark are used traditionally by the local population to treat leucorrhoea and diarrhoea, as anti-inflammatory and antiseptic agents (antimicrobial) and to promote blood clotting and wound healing, and in a few cases of gastric ulcers. A review of the literature presented a previous morpho-anatomical study only for S. adstringens (Mart.) Coville. The aim of the present work is to compare morpho-anatomically the stem bark and leaves of three species of Stryphnodendron, known popularly as barbatimão: S. adstringens, S. polyphyllum and S. obovatum, in order to help botanical identification and contribute to quality control. Macro- and microscopical evaluation of the stem barks revealed no significant differences among the species. Morphological analyses of the leaves revealed differences in size, coloration, and pubescence. The leaves of S. adstringens are the largest, glabrous, and concolor. The leaves of S. polyphyllum are smaller, pubescent, and discolor; whereas the leaves of S. obovatum are the same size as those of S. polyphyllum, however, they are glabrous, and discolor.
Resumo:
The clinical and histopathological effects of two alcoholic neurolytics were studied in horses. Normal horses were shod with a designed shoe adaptted with 5 screws to produce solar pain. After gait and lameness score analysis, the palmar nerve of 5 horses was injected with 5 ml of 0,75% benzyl alcohol (Group A) and 5 horses were injected with 5 ml of absolute ethyl alcohol (Group B). The animals were submitted to regular lameness evaluation and solar sensibility tests during next six months. The solar sensitivity returned 5 months latter in the group injected with benzyl alcohol 0,75%, while in the group injected with absolute ethyl alcohol, the sole was still desensitized 6 months latter. The histopathological findings showed that the nerve injected with benzyl alcohol 0,75%, resulted in axonotmesis, characterized by axonal nerve degeneration, with possibilities for the nerve conduction recovery. The perineural injection of ethyl alcohol absolute, resulted in neurotmesis with difficult nerve regeneration. It was concluded that chemical neurolysis with alcohol is an option for temporary or permanent nerve blocks in horses.