995 resultados para Capacité de développement organisationnelle
Resumo:
Carbonyl compounds are very important volatil organic compounds receiving increasing attention due to their critical role in tropospheric organic chemistry and to their effects on human health. They are first photo-oxidation stage of almost all organic compounds and originators of free radicals (OH, O3...). Therfore, continuous determination of their atmospheric concentrations is essential. Currently, field measurements are very limited mainly because of the analytical challenges posed by trace concentrations and interferences arising from atmospheric co-pollutants. Additionally, hydroxyl radical (OH) plays a central role in atmospheric chemistry processes. The measurement of atmospheric OH concentrations is essential for the comprehension of atmospheric chemical and photochemical processes. In this context, objectives of this work were: To perform a continuous survey of atmospheric concentrations of carbonyl compounds on different sites around the area of Bologna. For this purpose, an automatic instrument for the continuous measurement (one hour of time resolution) was developed and used. Additionally, the development of a complete and original analytical method was realised. To develop an original OH generation system in order to evaluate the effect of OH and the reactivity of solid and/or liquid materials of interest. This included the validation of an analytical method for the quantification of OH concentrations generated. Effect of OH on ceramic materials and reactivity of snow surface samples, involved as sink of OH in atmospheric chemistry, were evaluated.
Resumo:
In questa tesi di laurea si affronta l’analisi di diversi modelli per il calcolo della capacità di un’intersezione a rotatoria: alcuni di questi sono di tipo empirico, altri invece sono di tipo teorico (teoria del gap acceptance). Innanzitutto si descrivono le caratteristiche di tutti i modelli studiati e si esaminano i risultati ottenuti nel calcolo della capacità al variare del flusso circolante, effettuato su un campione di venti rotatorie. In particolare si cerca di confrontare tra loro i vari modelli e di interpretare il significato dei parametri che compaiono nelle diverse formule. Successivamente si amplia l’analisi, utilizzando i dati raccolti come punto di partenza per una serie di altre elaborazioni ed interpolazioni. Alla base di questa seconda parte dello studio c’è l’idea di provare a vedere se sia possibile ricavare un nuovo modello, derivante da quelli studiati, che possa riassumerli in maniera semplice e aiutare a chiarire quali sono i parametri più importanti dai quali dipende il valore di capacità di una rotatoria. Questo nuovo modello dovrebbe eventualmente servire più che altro per interpretare i modelli studiati e per capire se uno di questi si comporti meglio degli altri in situazioni particolari oppure se sia più adatto in determinate condizioni di traffico piuttosto che in altre. Uno degli obiettivi principali di questo studio è infatti quello di provare a capire se la capacità di una rotatoria è influenzata maggiormente da aspetti geometrici, legati quindi alla forma e alle dimensioni della rotatoria stessa, oppure se un ruolo predominante è svolto da fattori comportamentali, legati quindi all’interazione tra i veicoli e ai processi di scelta degli utenti, che devono decidere se immettersi o meno nella rotatoria.
Resumo:
This work is dedicated to the study of damaging phenomena involving reinforced concrete structures and masonry buildings and the consequences in terms of structural performances decay. In the Italian context there are many examples of structures that have already exceeded their service life, considering not only the ancient buildings but also infrastructures and R/C buildings that today are operating from more than 50th years. Climate change which is subject to the entire planet, with changing in seasonal weather and increasing in environmental pollution, is not excluded could have a harmful influence on the rate of building materials decay previously deemed as durables. If the aggressive input changes very fast, for example in a few decades, then it can also change the response of a construction material considered so far durable; in this way the knowledge about the art of good build, consolidated over the centuries, is thwarted. Hence this study is focused on the possibility to define the residual capacity for vertical or seismic loads for structures that are already at the limit of their service life, or for which is impossible to define a service life. The problem in an analysis of this kind, and that is what makes this research different from the main studies avaibles in the literature, is to keep in correlation – in a not so expensive computationally way – issues such as: - dangerous environmental inputs adequately simulated; - environmental conditions favorable to the spread of pollutants and development of the degradation reactions (decay’s speed); - link between environmental degradation and residual bearing capacity A more realistic assessment of materials residual performances that constitute the structure allows to leave the actual system for the residual load-bearing capacity estimation in which all factors are simply considered through the use of a safety factor on the materials properties.
Resumo:
The aim of the present thesis, carried out at the Analytical Group of the Faculty of Industrial Chemistry in Bologna, is to develop a new electrochemical method for the determination of the Antioxidant Capacity (AOC). The approach is based on the deposition of a non-conducting polymeric film on the working electrode surface and the following exposition to the radicals OH· produced by H2O2 photolysis. The strongly oxidant action of hydroxyl radicals degrades, causing an increase of the Faradic current, relevant to the redox couple [Ru(NH3)6]2+/3+ monitored by cyclic voltammetry(CV); the presence of an antioxidant compound in solution slows down the radical action, thus protecting the polymeric film and blocking the charge transfer. The parameter adopted for the quantification of the AOC, was the induction time, called also lag phase, which is the time when the degradation of the film starts. Five pure compounds, among most commonly antioxidant, were investigated : Trolox®(an analogue water-soluble of vitamin E), (L)-ascorbic acid, gallic acid, pyrogallol and (-)- epicatechin. The AOC of each antioxidant was expressed by TEAC index (Trolox® Equivalent Antioxidant Capacity), calculated from the ratio between the slope of the calibration curve of the target compound and the slope of the calibration curve of Trolox®. The results from the electrochemical method, have been compared with those obtained from some other standardized methods, widely employed. The assays used for the comparison, have been: ORAC, a spectrofluorimetric method based on the decrease of fluorescein emission after the attack of alkylperoxide radicals, ABTS and DPPH that exploit the decoloration of stable nitrogen radicals when they are reduced in presence of an antioxidant compound and, finally, a potentiometric method based on the response of the redox couple [Fe(CN)6]3-/ [Fe(CN)6]4-. From the results obtained from pure compounds, it has been found that ORAC is the methodology showing the best correlation with the developed electrochemical method, maybe since similar radical species are involved. The comparison between the considered assays, was also extended to the analysis of a real sample of fruit juice. In such a case the TEAC value resulting from the electrochemical method is higher than those from standardized assays.