PURPOSE. To determine whether internal limiting membrane (ILM) peeling is effective and cost effective compared with no peeling in patients with idiopathic stage 2 or 3 full-thickness maculay hole (FTMH). METHODS. This was a pragmatic multicenter randomized controlled trial. Eligible participants from nine centers were randomized to ILM peeling or no peeling (1:1 ratio) in addition to phacovitrectomy, including detachment and removal of the posterior hyaloid and gas tamponade. The primary outcome was distance visual acuity (VA) at 6 months after surgery. Secondary outcomes included hole closure, distance VA at other time points, near VA, contrast sensitivity, reading speed, reoperations, complications, resource use, and participant-reported health status, visual function, and costs. RESULTS. Of 141 participants randomized in nine centers, 127 (90%) completed the 6-month follow-up. Nonstatistically significant differences in distance visual acuity at 6 months were found between groups (mean difference, 4.8; 95% confidence interval [CI], -0.3 to 9.8; P = 0.063). There was a significantly higher rate of hole closure in the ILM-peel group (56 [84%] vs. 31 [48%]) at 1 month (odds ratio [OR], 6.23; 95% CI, 2.64-14.73; P <0.001) with fewer reoperations (8 [12%] vs. 31 [48%]) performed by 6 months (OR, 0.14; 95% CI, 0.05- 0.34; P <0.001). Peeling the ILM is likely to be cost effective. CONCLUSIONS. There was no evidence of a difference in distance VA after the ILM peeling and no-ILM peeling techniques. An important benefit in favor of no ILM peeling was ruled out. Given the higher anatomic closure and lower reoperation rates in the ILM-peel group, ILM peeling seems to be the treatment of choice for idiopathic stage 2 to 3 FTMH. © 2011 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To determine whether internal limiting membrane (ILM) peeling is cost-effective compared with no peeling for patients with an idiopathic stage 2 or 3 full-thickness macular hole. Methods: A cost-effectiveness analysis was performed alongside a randomised controlled trial. 141 participants were randomly allocated to receive macular-hole surgery, with either ILM peeling or no peeling. Health-service resource use, costs and quality of life were calculated for each participant. The incremental cost per quality-adjusted life year (QALY) gained was calculated at 6 months. Results: At 6 months, the total costs were on average higher (£424, 95% CI -182 to 1045) in the No Peel arm, primarily owing to the higher reoperation rate in the No Peel arm. The mean additional QALYs from ILM peel at 6 months were 0.002 (95% CI 0.01 to 0.013), adjusting for baseline EQ-5D and other minimisation factors. A mean incremental cost per QALY was not computed, as Peeling was on average less costly and slightly more effective. A stochastic analysis suggested that there was more than a 90% probability that Peeling would be cost-effective at a willingness-to-pay threshold of £20 000 per QALY. Conclusion: Although there is no evidence of a statistically significant difference in either costs or QALYs between macular hole surgery with or without ILM peeling, the balance of probabilities is that ILM Peeling is likely to be a cost-effective option for the treatment of macular holes. Further long-term follow-up data are needed to confirm these findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG).

METHODS: Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model.

RESULTS: Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0-62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17-68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14-64 and 39, 95% CrI 3-64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty.

CONCLUSIONS: No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests.