1000 resultados para 157-956
Resumo:
OBJECTIVES: We evaluated the prenatal detection of gastrointestinal obstruction (GIO, including atresia, stenosis, absence or fistula) by routine ultrasonographic examination in an unselected population all over Europe. METHODS: Data from 18 congenital malformation registries in 11 European countries were analysed. These multisource registries used the same methodology. All fetuses/neonates with GIO confirmed within 1 week after birth who had prenatal sonography and were born during the study period (1 July 1996 to 31 December 1998) were included. RESULTS: There were 670 793 births in the area covered and 349 fetuses/neonates had GIO. The prenatal detection rate of GIO was 34%; of these 40% were detected < or = 24 weeks of gestation (WG). A total of 31% (60/192) of the isolated GIO were detected prenatally, as were 38% (59/157) of the associated GIO (p=0.26). The detection rate was 25% for esophageal obstruction (31/122), 52% for duodenal obstruction (33/64), 40% for small intestine obstruction (27/68) and 29% for large intestine obstruction (28/95) (p=0.002). The detection rate was higher in countries with a policy of routine obstetric ultrasound. Fifteen percent of pregnancies were terminated (51/349). Eleven of these had chromosomal anomalies, 31 multiple malformations, eight non-chromosomal recognized syndromes, and one isolated GIO. The participating registries reflect the various national policies for termination of pregnancy (TOP), but TOPs after 24 WG (11/51) do not appear to be performed more frequently in countries with a liberal TOP policy. CONCLUSION: This European study shows that the detection rate of GIO depends on the screening policy and on the sonographic detectability of GIO subgroups.
Resumo:
We present a compact portable biosensor to measure arsenic As(III) concentrations in water using Escherichia coli bioreporter cells. Escherichia coli expresses green fluorescent protein in a linearly dependent manner as a function of the arsenic concentration (between 0 and 100 μg/L). The device accommodates a small polydimethylsiloxane microfluidic chip that holds the agarose-encapsulated bacteria, and a complete optical illumination/collection/detection system for automated quantitative fluorescence measurements. The device is capable of sampling water autonomously, controlling the whole measurement, storing and transmitting data over GSM networks. We demonstrate highly reproducible measurements of arsenic in drinking water at 10 and 50 μg/L within 100 and 80 min, respectively.
Resumo:
S100B is a prognostic factor for melanoma as elevated levels correlate with disease progression and poor outcome. We determined its prognostic value based on updated information using serial determinations in stage IIb/III melanoma patients. 211 Patients who participated in the EORTC 18952 trial, evaluating efficacy of adjuvant intermediate doses of interferon α2b (IFN) versus observation, entered a corollary study. Over a period of 36 months, 918 serum samples were collected. The Cox time-dependent model was used to assess prognostic value of the latest (most recent) S100B determination. At first measurement, 178 patients had S100B values <0.2 μg/l and 33 ≥ 0.2 μg/l. Within the first group, 61 patients had, later on, an increased value of S100B (≥ 0.2 μg/l). An initial increased value of S100B, or during follow-up, was associated with worse distant metastasis-free survival (DMFS); hazard ratio (HR) of S100B ≥ 0.2 versus S100B < 0.2 was 5.57 (95% confidence interval (CI) 3.81-8.16), P < 0.0001, after adjustment for stage, number of lymph nodes and sex. In stage IIb patients, the HR adjusted for sex was 2.14 (95% CI 0.71, 6.42), whereas in stage III, the HR adjusted for stage, number of lymph nodes and sex was 6.76 (95% CI 4.50-10.16). Similar results were observed regarding overall survival (OS). Serial determination of S100B in stage IIb-III melanoma is a strong independent prognostic marker, even stronger compared to stage and number of positive lymph nodes. The prognostic impact of S100B ≥ 0.2 μg/l is more pronounced in stage III disease compared with stage IIb.
Resumo:
Estrella lausannensis is a new Chlamydia-related bacterium, belonging to the Criblamydiaceae family. As suggested by its species name, this bacterium harbors a peculiar star shape. E. lausannensis is able to infect a wide range of amoebal, fish and mammalian cell lines. Moreover, seroprevalence of 2.9% was reported in children and in women with tubal pathology, showing that humans are commonly exposed to this recently discovered strict intracellular bacteria considered as a potential pathogen. Antibiotic susceptibility was determined using two approaches: qPCR and cellular mortality assay. Antibiotics classically used against intracellular bacteria were tested, including β-lactams, fluoroquinolones, cyclines and macrolides. We showed that E. lausannensis is resistant to β-lactams and fluoroquinolones, and sensitive to cyclines. Interestingly, E. lausannensis is slightly resistant to azithromycin with a MIC of 2 μg/ml, which is 10 fold higher compared to Waddlia chondrophila and Parachlamydia acanthamoebae MIC's. A single A2059C mutation in 23S rRNA gene could be responsible for this unexpected resistance.
Resumo:
British mammalogists have used two different systems for surveying the common dormouse Muscardinus avellanarius: a modified bird nest box with the entrance facing the tree trunk, and a smaller, cheaper model called a "nest tube". However, only few data comparing different nest box systems are currently available. To determine which system is more efficient, we compared the use of the large (GB-type) and small nest boxes (DE-type, a commercial wooden mouse trap without a door) in three Swiss forest. The presence of Muscardinus, potential competitors, and any evidence of occupation were examined in 60 pairs of nest boxes based on 2,280 nest box checks conducted over 5 years. Mean annual occupation and cumulative numbers of Muscardinus present were both significantly higher for the DE than for the GB boxes (64.6% versus 32.1%, and 149 versus 67 dormice, respectively). In contrast, the annual occupation by competitors including Glis glis, Apodemus spp. and hole-nesting birds was significantly higher in the GB than in the DE boxes in all forest (19-68% versus 0-16%, depending on the species and forest). These results suggest that smaller nest boxes are preferred by the common dormouse and are rarely occupied by competitors. These boxes hence appear to be preferable for studying Muscardinus populations.
Resumo:
A liquid chromatography method coupled to mass spectrometry was developed for the quantification of bupropion, its metabolite hydroxy-bupropion, moclobemide, reboxetine and trazodone in human plasma. The validation of the analytical procedure was assessed according to Société Française des Sciences et Techniques Pharmaceutiques and the latest Food and Drug Administration guidelines. The sample preparation was performed with 0.5mL of plasma extracted on a cation-exchange solid phase 96-well plate. The separation was achieved in 14min on a C18 XBridge column (2.1mm×100mm, 3.5μm) using a 50mM ammonium acetate pH 9/acetonitrile mobile phase in gradient mode. The compounds of interest were analysed in the single ion monitoring mode on a single quadrupole mass spectrometer working in positive electrospray ionisation mode. Two ions were selected per molecule to increase the number of identification points and to avoid as much as possible any false positives. Since selectivity is always a critical point for routine therapeutic drug monitoring, more than sixty common comedications for the psychiatric population were tested. For each analyte, the analytical procedure was validated to cover the common range of concentrations measured in plasma samples: 1-400ng/mL for reboxetine and bupropion, 2-2000ng/mL for hydroxy-bupropion, moclobemide, and trazodone. For all investigated compounds, reliable performance in terms of accuracy, precision, trueness, recovery, selectivity and stability was obtained. One year after its implementation in a routine process, this method demonstrated a high robustness with accurate values over the wide concentration range commonly observed among a psychiatric population.
Resumo:
A generic LC-MS approach for the absolute quantification of undigested peptides in plasma at mid-picomolar levels is described. Nine human peptides namely, brain natriuretic peptide (BNP), substance P (SubP), parathyroid hormone 1-34 (PTH), C-peptide, orexines A and B (Orex-A and -B), oxytocin (Oxy), gonadoliberin-1 (gonadothropin releasing-hormone or luteinizing hormone-releasing hormone, LHRH) and α-melanotropin (α-MSH) were targeted. Plasma samples were extracted via a 2-step procedure: protein precipitation using 1vol of acetonitrile followed by ultrafiltration of supernatants on membranes with a MW cut-off of 30 kDa. By applying a specific LC-MS setup, large volumes of filtrates (e.g., 2×750 μL) were injected and the peptides were trapped on a 1mm i.d.×10 mm length C8 column using a 10× on-line dilution. Then, the peptides were back-flushed and a second on-line dilution (2×) was applied during the transfer step. The refocalized peptides were resolved on a 0.3mm i.d. C18 analytical column. Extraction recovery, matrix effect and limits of detection were evaluated. Our comprehensive protocol demonstrates a simple and efficient sample preparation procedure followed by the analysis of peptides with limits of detection in the mid-picomolar range. This generic approach can be applied for the determination of most therapeutic peptides and possibly for endogenous peptides with latest state-of-the-art instruments.
Resumo:
Il s'agit de comparer in vivo la sécurité et l'efficacité d'un implant en polyméthylméthacrylate (PMMA) avec un implant standard en collagène dans la sclérectomie profonde (SP) sur une durée de six mois. La population étudiée comprend vingt lapins, chaque lapin étant randomisé pour une SP avec implant en PMMA dans un oeil et implant de collagène dans l'autre oeil. Plusieurs éléments ont été pris en compte dans la comparaison : - la mesure de la pression intraoculaire - l'évolution de l'espace de drainage intrascléral et de la bulle de filtration sous-conjonctivale, suivie par ultrasonographic biomicroscopique (UBM) - la croissance de nouveaux vaisseaux de drainage sous-conjonctivaux, croissance quantifiée par angiographie du segment antérieur à la fluorescéine combinée au vert d'indocyanine - la facilité à l'écoulement de l'humeur aqueuse (C), mesurée à six mois par cannulation-perfusion de la chambre antérieur - la sclère au site de SP, histologiquement comparée à la sclère native opposée à 180°, également à six mois La pression intraoculaire moyenne préopératoire à une, quatre, douze et 24 semaines postopératoires est comparable dans les deux groupes (P>0.1). L'UBM montre une régression légèrement plus rapide (statistiquement non significative) de la bulle de filtration sous-conjonctivale et la persistance d'un espace de drainage intrascléral dans le groupe PMMA (P>0.05). De nouveaux vaisseaux de drainage sont observés à un mois de la chirurgie ; à six mois, ces vaisseaux sont plus nombreux dans le groupe PMMA, tant sur l'analyse angiographique que sur l'analyse histologique (P>0.05). La facilité moyenne à l'écoulement de l'humeur aqueuse est significativement plus élevées à six mois dans les deux groupes par rapport aux valeurs préopératoires (P>0.05), sans qu'il n'y ait de différence entre les deux implants (0.24 ± 0.06 μΙ/min/mmHg [PMMA] et 0.23 ± 0.07 μΙ/min/mmHg [implant en collagène]) (Ρ = 0.39). Cette étude a pu démontrer que la sclérectomie profonde avec implant en collagène ou en PMMA donne des résultats similaires en terme de diminution de l'IOP et d'augmentation de la facilité à l'écoulement de l'humeur aqueuse, sans différence sur le plan des réactions inflammatoires post-intervention.