980 resultados para ultrafine particle concentration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper assesses blood alcohol concentration and risk behaviors for traffic accidents before and after the implementation of a law which prohibits the use of alcoholic beverages on city gas stations. In Porto Alegre, Southern Brazil, young people go out at night and drive to gas station convenience stores to buy alcoholic beverages which are consumed on the premises of parking lots in gas stations. Data were obtained from self-administered questionnaires and breath analyzers in two cross-sectional collections with purposive samples of youngsters in May and July 2006 (n=62, and n=50, respectively). There were no significant differences between the groups before and after the city law was passed. Blood alcohol concentration greater than 0.06% was found in 35.5% of pre-law group and 40% of post-law group (p=0.62). Results point out heavy alcohol use in both groups, which did not change after the law was passed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine self-consistently the time evolution of particle size and their number density in situ multi-angle polarization-sensitive laser light scattering was used. Cross-polarization intensities (incident and scattered light intensities with opposite polarization) measured at 135 degrees and ex situ transmission electronic microscopy analysis demonstrate the existence of nonspherical agglomerates during the early phase of agglomeration. Later in the particle time development both techniques reveal spherical particles again. The presence of strong cross-polarization intensities is accompanied by low-frequency instabilities detected on the scattered light intensities and plasma emission. It is found that the particle radius and particle number density during the agglomeration phase can be well described by the Brownian free molecule coagulation model. Application of this neutral particle coagulation model is justified by calculation of the particle charge whereby it is shown that particles of a few tens of nanometer can be considered as neutral under our experimental conditions. The measured particle dispersion can be well described by a Brownian free molecule coagulation model including a log-normal particle size distribution. (C) 1996 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho teve como objectivo a avaliação da actual situação da indústria corticeira, o levantamento de eventuais possibilidades de inovação e o estudo de um caso promissor. Como caso promissor, decidiu-se estudar o efeito da pirólise nos resíduos de cortiça. A análise da situação actual da indústria corticeira aponta para a procura de novos produtos no sentido de alargar o mercado e promover um melhor escoamento deste recurso natural. Apesar de todos os esforços efectuados até ao momento, verifica-se que a indústria vinícola continua a ser o principal mercado da cortiça. O avanço da tecnologia tem permitido o desenvolvimento de novos produtos, alguns ainda em fase de desenvolvimento, e aponta para um potencial de inovação a vários níveis: ao nível do processo de transformação, no sentido da sua optimização; ao nível do desenvolvimento de novos produtos dado o potencial já demonstrado pela cortiça em desenvolvimentos recentes; ao nível da valorização de resíduos como, por exemplo, a consolidação de processo de recuperação de taninos da água de cozedura, a obtenção de suberina e poliois do pó e aparas de cortiça e a pirólise das aparas e pó de cortiça. Como estudo de caso, efectuou-se o estudo do efeito da pirólise em resíduos de cortiça natural, para se poder conhecer as características dos produtos obtidos bem como as condições óptimas de operação. Neste fase inicial e optou-se por se analisar as propriedades parte sólida de modo a saber as alterações sofridas durante a pirólise e estas podem apresentar uma mais-valia para o mercado corticeiro. Para efectuar o respectivo trabalho, recorreu-se a um forno pirolítico horizontal tipo Splitz e utilizou-se cortiça natural com granulometria entre 2,88 e 4,00mm. A pirólise foi realizada entre a gama de temperaturas de 400 e 900ºC e para duas rampas de aquecimento de 5ºC/min e 10ºC/min. O estudo experimental revela que na gama de temperaturas entre os 600 e 800ºC é onde a carbonização do resíduo está completa, sendo para essa mesma gama de temperaturas que se verifica, no resíduo carbonoso, um maior teor de carbono. Relativamente às rampas de aquecimento estas não apresentam efeitos significativos nas massas e teores de carbono no resíduo carbonoso final. Verificouse também, que o teor de hidrogénio diminui com o aumento da temperatura. Conclui-se que a pirólise consegue degradar os resíduos de cortiça levando à libertação de compostos que poderão ser uma mais-valia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method using a hanging mercury drop electrode (HMDE) has been developed for determination of the herbicide molinate in a biodegradation process. The method is based on controlled adsorptive accumulation of molinate for 10 s at a potential of -0.8 V versus AgCl/Ag. An anodic peak, due to oxidation of the adsorbed pesticide, was observed in the cyclic voltammogram at ca. -0.320 V versus AgCl/Ag; a very small cathodic peak was also detected. The SWV calibration plot was established to be linear in the range 5.0x10-6 to 9.0x10-6 mol L-1; this corresponded to a detection limit of 3.5x10-8 mol L-1. This electroanalytical method was used to monitor the decrease of molinate concentration in river waters along a biodegradation process using a bacterial mixed culture. The results achieved with this voltammetric method were compared with those obtained by use of a chromatographic method (HPLC–UV) and no significant statistical differences were observed.