992 resultados para shear test
Resumo:
N = 1 designs imply repeated registrations of the behaviour of the same experimental unit and the measurements obtained are often few due to time limitations, while they are also likely to be sequentially dependent. The analytical techniques needed to enhance statistical and clinical decision making have to deal with these problems. Different procedures for analysing data from single-case AB designs are discussed, presenting their main features and revising the results reported by previous studies. Randomization tests represent one of the statistical methods that seemed to perform well in terms of controlling false alarm rates. In the experimental part of the study a new simulation approach is used to test the performance of randomization tests and the results suggest that the technique is not always robust against the violation of the independence assumption. Moreover, sensitivity proved to be generally unacceptably low for series lengths equal to 30 and 40. Considering the evidence available, there does not seem to be an optimal technique for single-case data analysis
Resumo:
OBJECTIVE: This pilot experimental study tested the feasibility and intended effect of an educational intervention for parents to help them assist their adolescent child with chronic illness (CI) in becoming autonomous. METHODS: A two-phase pre-post pilot intervention study targeting parents of adolescents with CI was conducted. Parents were allocated to group 1 and 2 and received the four-module intervention consecutively. Intended effect was measured through online questionnaires for parents and adolescents before, at 2 months after, and at 4-6 months after the intervention. Feasibility was assessed through an evaluation questionnaire for parents. RESULTS: The most useful considered modules concerned the future of the adolescent and parents and social life. The most valued aspect was to exchange with other parents going through similar problems and receiving a new outlook on their relationship with their child. For parents, improvement trends appeared for shared management, parent protection, and self-efficacy, and worsening trends appeared for coping skills, parental perception of child vulnerability, and parental stress. For adolescents, improvement trends appeared for self-efficacy and parental bonding and worsening trends appeared for shared management and coping skills. CONCLUSION: Parents could benefit from peer-to-peer support and education as they support the needed autonomy development of their child. Future studies should test an online platform for parents to find peer support at all times and places.
Resumo:
Water is vital to humans and each of us needs at least 1.5 L of safe water a day to drink. Beginning as long ago as 1958 the World Health Organization (WHO) has published guidelines to help ensure water is safe to drink. Focused from the start on monitoring radionuclides in water, and continually cooperating with WHO, the International Standardization Organization (ISO) has been publishing standards on radioactivity test methods since 1978. As reliable, comparable and"fit for purpose" results are an essential requirement for any public health decision based on radioactivity measurements, international standards of tested and validated radionuclide test methods are an important tool for production of such measurements. This paper presents the ISO standards already published that could be used as normative references by testing laboratories in charge of radioactivity monitoring of drinking water as well as those currently under drafting and the prospect of standardized fast test methods in response to a nuclear accident.
Resumo:
Diplomityössä tutkitaan diodilaserhitsausta mahdollisena teollisuuden menetelmänä ja menetelmän vaatimuksia hitsattaessa ohutlevyjä. Työssä tutkittavat materiaalit ovat kylmävalssattu teräs ja ruostumaton teräs sekä liitosmuotoina päittäis-, laippa- ja päällekkäisliitos. Materiaalivahvuudet ovat 0,50 mm:stä 1,50 mm:iin. Työn tavoitteena on määrittää näille kyseisille materiaaleille ja liitosmuodoille hitsausnopeus levynvahvuuden funktiona. Lisäksi käsitellään diodilaserin rakennetta, säteen muodostusta, säteen muokkaamista, säteen analysointia ja säteen turvallisuuteen liittyviä asioita. Suoritetaan vertailua käytössä oleviin muihin lasertyöstömenetelmiin konepajoissa ja tehdään arvio mahdollisen diodilaserinvestoinnin kannattavuudesta. Diodilaserhitsauskokeissa käytettiin Hämeen ammattikorkeakoulun Riihimäen yksikön 1 kW:n tehoista diodilaseria. Koekappaleet leikattiin suuntaisleikkurilla. Osalle hitsatuista kappaleista tehtiin poikittaiset vetokokeet ja mitattiin mikrokovuudet. Virheitä tutkittiin silmämääräisesti sekä radiografisella kuvauksella. Kaikille tutkituille liitoksille, materiaaleille ja vahvuuksille saatiin määriteltyä hitsausnopeudet. Tehtyjen testien perusteella suuntaisleikkurin käyttö on mahdollista. Lisäksi havaittiin suojakaasun käytön myötä, että kirkkaan sulan aiheuttama heijastavuuden kasvu edellyttää hitsausnopeuden pienentämistä.
Resumo:
Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
Resumo:
By means of computer simulations and solution of the equations of the mode coupling theory (MCT),we investigate the role of the intramolecular barriers on several dynamic aspects of nonentangled polymers. The investigated dynamic range extends from the caging regime characteristic of glass-formers to the relaxation of the chain Rouse modes. We review our recent work on this question,provide new results, and critically discuss the limitations of the theory. Solutions of the MCT for the structural relaxation reproduce qualitative trends of simulations for weak and moderate barriers. However, a progressive discrepancy is revealed as the limit of stiff chains is approached. This dis-agreement does not seem related with dynamic heterogeneities, which indeed are not enhanced by increasing barrier strength. It is not connected either with the breakdown of the convolution approximation for three-point static correlations, which retains its validity for stiff chains. These findings suggest the need of an improvement of the MCT equations for polymer melts. Concerning the relaxation of the chain degrees of freedom, MCT provides a microscopic basis for time scales from chain reorientation down to the caging regime. It rationalizes, from first principles, the observed deviations from the Rouse model on increasing the barrier strength. These include anomalous scaling of relaxation times, long-time plateaux, and nonmonotonous wavelength dependence of the mode correlators.
Resumo:
Endothelial cell release of nitric oxide (NO) is a defining characteristic of nondiseased arteries, and abnormal endothelial NO release is both a marker of early atherosclerosis and a predictor of its progression and future events. Healthy coronaries respond to endothelial-dependent stressors with vasodilatation and increased coronary blood flow (CBF), but those with endothelial dysfunction respond with paradoxical vasoconstriction and reduced CBF. Recently, coronary MRI and isometric handgrip exercise (IHE) were reported to noninvasively quantify coronary endothelial function (CEF). However, it is not known whether the coronary response to IHE is actually mediated by NO and/or whether it is reproducible over weeks. To determine the contribution of NO, we studied the coronary response to IHE before and during infusion of N(G)-monomethyl-l-arginine (l-NMMA, 0.3 mg·kg(-1)·min(-1)), a NO-synthase inhibitor, in healthy volunteers. For reproducibility, we performed two MRI-IHE studies ∼8 wk apart in healthy subjects and patients with coronary artery disease (CAD). Changes from rest to IHE in coronary cross-sectional area (%CSA) and diastolic CBF (%CBF) were quantified. l-NMMA completely blocked normal coronary vasodilation during IHE [%CSA, 12.9 ± 2.5 (mean ± SE, placebo) vs. -0.3 ± 1.6% (l-NMMA); P < 0.001] and significantly blunted the increase in flow [%CBF, 47.7 ± 6.4 (placebo) vs. 10.6 ± 4.6% (l-NMMA); P < 0.001]. MRI-IHE measures obtained weeks apart strongly correlated for CSA (P < 0.0001) and CBF (P < 0.01). In conclusion, the normal human coronary vasoactive response to IHE is primarily mediated by NO. This noninvasive, reproducible MRI-IHE exam of NO-mediated CEF promises to be useful for studying CAD pathogenesis in low-risk populations and for evaluating translational strategies designed to alter CAD in patients.
Resumo:
Quartz tuning forks are extremely good resonators and their use is growing in scanning probe microscopy. Nevertheless, only a few studies on soft biological samples have been reported using these probes. In this work, we present the methodology to develop and use these nanosensors to properly work with biological samples. The working principles, fabrication and experimental setup are presented. The results in the nanocharacterization of different samples in different ambients are presented by using different working modes: amplitude modulation with and without the use of a Phase-Locked Loop (PLL) and frequency modulation. Pseudomonas aeruginosa bacteria are imaged in nitrogen using amplitude modulation. Microcontact printed antibodies are imaged in buffer using amplitude modulation with a PLL. Finally, metastatic cells are imaged in air using frequency modulation.
Resumo:
Työn tavoitteena oli löytää painelajittimen roottorin keskeiset muuttujat ja ajoparametrit, kun pyritään jälkilajittelemaan valkaistua sellumassaa korkeassa sakeudessa, sekä näiden vaikutukset. Tavoitteena oli teknisesti onnistunut lajittelu korkeassa sakeudessa siten, että laitteen puhdistustehokkuus on hyvä, ominaisenergian kulutus on pieni ja kapasiteetti on korkea. Ensin tarkasteltiin kuitenkin teoreettisesti valkaistun sellumassan painelajittelun ongelmakenttää, keskeisten epäpuhtauksien poistoa jälkilajittelussa ja vertailtiin korkea- ja matalasakeuslajittelua. Lisäksi esiteltiin yleisellä tasolla koesuunnittelumenetelmien periaatteita ja menetelmiä sekä analyysiä so. mallinnus. Tätä taustaa vasten haluttiin myös kartoittaa ja esitellä painelajittimen keskeinen muuttujakenttä. Tämän jälkeen selvitettiin kokeellisesti miten ajettavan valkaistun mäntysellumassan sakeus, roottorin kehänopeus ja roottorin rakenteen muutokset vaikuttavat painelajittimen kapasiteettiin, rejektin sakeutumiskertoimeen, ominaisenergian kulutukseen ja puhdistustehokkuuteen. Vaikutusten ja parhaan roottorirakenteen sekä ajosuureiden määritys suoritettiin mallintamalla mittaustulokset lineaarisella regressioanalyysilla. Saatiin tärkeimmät vasteisiin vaikuttavat riippumattomat muuttujat ja niiden matemaattiset esityk-set, malliyhtälöt. Mallinnusta hyväksi käyttäen tarkasteltiin vielä erikseen yhden roottorin ajoa. Tärkeimpinä tuloksina saatiin selville, että puhdistustehokkuus on lähes vakio tietyllä roottorirakenteella riippumatta sakeudesta ja roottorin kehänopeudesta. Edullista puhdistustehokkuuden kannalta on käyttää ensisijaisesti isoa roottorin palaelementin korkeutta ja välystä suhteessa sihtirumpuun. Jälkilajittelu painelajittimella korkeassa sakeudessa kannattaa suorittaa pienellä roottorin kehänopeudella, runko- ja palaelementtivälyksellä suhteessa sihtirumpuun sekä suurella palaelementin korkeudella. Tällöin saavutetaan hyvä kompromissi ominaisenergian kulutuksen ja laitteen ajettavuuden osalta. Iso elementin korkeus ja pieni elementtivälys eivät aja massaa tehokkaasti laitteen alaosaan. Tällöin ei pyöritetä myöskään suurta massamäärää. Pieni elementtivälys mahdollistaa myös massan tehokkaamman leikkauksen, joka parantaa fluidisoitumista. Kitkavoimat ovat luonnollisesti ko. olosuhteissa suuremmat, joten ominais-energian kulutus kasvaa jonkin verran. Ratkaisevinta ominaisenergian kulutuksen kannalta on kuitenkin ajaa laitetta pienellä kehänopeudella.
Resumo:
Differentiation between photoallergenic and phototoxic reactions induced by low molecular weight compounds represents a current problem. The use of eratinocytes as a potential tool for the detection of photoallergens as opposed to photoirritants is considered an interesting strategy for developing in vitro methods. We have previously demonstrated the possibility to use the human keratinocyte cell line NCTC2455 and the production of interleukin-18 (IL-18) to screen low molecular weight sensitizers. The purpose of this work was to explore the possibility to use the NCTC2544 assay to identify photoallergens and discriminate from phototoxic chemicals. First, we identified suitable condition of UV-irradiation (3.5 J/cm2) by investigating the effect of UVAirradiation on intracellular IL-18 on untreated or chloropromazine (a representative phototoxic compound)- treated NCTC2544 cells. Then, the effect of UVA-irradiation over NCTC2544 cells treated with increasing concentrations of 15 compounds including photoallergens (benzophenone, 4-ter-butyl-4-methoxydibenzoylmethane, 2-ethylexyl-p-methoxycinnamate, ketoprofen, 6-methylcumarin); photoirritant and photoallergen (4-aminobenzoic acid, chlorpromazine, promethazine); photoirritants (acridine, ibuprofen, 8-methoxypsoralen, retinoic acid); and negative compounds (lactic acid, SDS and p-phenilendiamine) was investigated. Twenty-four hours after exposure, cytotoxicity was evaluated by the MTT assay or LDH leakage, while ELISA was used to measure the production of IL-18. At the maximal concentration assayed with non-cytotoxic effects (CV80 under irradiated condition), all tested photoallergens induced a significant and a dose-dependent increase of intracellular IL-18 following UVA irratiation, whereas photoirritants failed. We suggest that this system may be useful for the in vitro evaluation of the photoallergic potential of chemicals.
Resumo:
Suunniteltiin ja rakennettiin suoraa vääntömomenttisäätöä soveltava taajuudenmuuttajakäyttö oikosulkumoottorin ohjaukseen korvaamaan passiivinen jarrukäyttö. Laite on kuntoutuslaite, jolla tehdään lihasvoiman mittauksia ja voimaharjoituksia. Selvitettiin kaupallisten moottoreiden ja taajuudenmuuttajien suoritusominaisuuksia ja tämän perusteella valittiin käyttöön sopivat laitteet. Työssä esitetään kaksi oikosulkumoottorin ohjaustapaa: vektorisäätö ja suora vääntömomenttisäätö. Merkittävin osa tästä työstä käsittelee - tarkan turvallisuussuunnitelman lisäksi - kuntoutuslaitteen prototyypin komponentteja, kokoamista ja suoritustestien tuloksia.