979 resultados para rib graft
Resumo:
OBJECTIVE: To analyze the lesions diagnosed in victims of falls, comparing them with those diagnosed in other mechanisms of blunt trauma.METHODS: We conducted a retrospective study of trauma protocol charts (prospectively collected) from 2008 to 2010, including victims of trauma over 13 years of age admitted to the emergency room. The severity of injuries was stratified by the Abbreviated Injury Scale (AIS) and Injury Severity Score (ISS). Variables were compared between the group of victims of falls from height (Group 1) and the other victims of blunt trauma (Group 2). We used the Student t, chi-square and Fisher tests for comparison between groups, considering the value of p <0.05 as significant.RESULTS: The series comprised 4,532 cases of blunt trauma, of which 555 (12.2%) were victims of falls from height. Severe lesions (AISe"3) were observed in the extremities (17.5%), in the cephalic segment (8.4%), chest (5.5%) and the abdomen (2.9%). Victims of Group 1 had significantly higher mean age, AIS in extremities / pelvis, AIS in the thoracic segment and ISS (p <0.05). The group 1 had significantly (p <0.05) higher incidence of tracheal intubation on admission, pneumothorax, hemothorax, rib fractures, chest drainage, spinal trauma, pelvic fractures, complex pelvic fractures and fractures to the upper limbs.CONCLUSION: Victims of fall from height had greater anatomic injury severity, greater frequency and severity of lesions in the thoracic segment and extremities.
Resumo:
OBJECTIVE: to verify the effectiveness of the rubber elastic band in the treatment of large wounds of the body wall of rabbits by means of traction of its edges. METHODS: we studied 30 New Zealand rabbits, divided into three groups (n=10): Group 1- healing by secondary intention; Group 2- removal and eutopic repositioning of skin as full thickness skin graft; Group 3- Approximation of wound edges with elastic rubber band. In all animals, we removed a segment of the back skin and subcutaneous tissue down to the fascia, in accordance with an acrylic mold of 8cm long by 12cm wide. All animals were observed for 21 days. RESULTS: two animals of groups 1 and 2 had wound abscess. In Group 2, there was partial or total graft loss in 90% of animals. The complete closure of the wounds was observed in four animals of Group 1, six of Group 2 and eight of Group 3. There was no difference between the scar resistance values of groups 2 and 3, which were higher than those in Group 1. The scars of the three groups were characterized by the presence of mature connective tissue mixed with blood vessels and inflammatory infiltration, predominantly polymorphonuclear. CONCLUSION: the tensile strength of the wound edges with rubber elastic band is as efficient as the skin graft to treat rabbits' large body wounds.
Resumo:
Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.
Resumo:
ABSTRACTObjective:to analyze the associated factors with empyema in patients with post-traumatic retained hemothorax.Methods:prospective observational study. Data were collected in patients undergoing PD during emergency duty. Variables analyzed were age, sex, mechanism of injury, side of the chest injury, intrathoracic complications of RH, laparotomy, specific injuries, rib fractures, trauma scores, days to diagnosis, diagnostic method of RH, primary indication of PD, initial volume drained, length of the first tube removal, surgical procedure. Cumulative incidence of empyema, pneumonia and pulmonary contusion and the proportion of patients with empyema or without empyema in each category of each variable analyzed were obtained.Results: the cumulative incidence of PD among trauma patients was 1.83% and the RH among those with PD was 10.63%. There were 20 cases of empyema (32.8%). Most were male in the age from 20 to 29, victims of injury by firearm on the left side of the thorax. The incidence of empyema in patients with injury by firearms was lower compared to those with stab wound or blunt trauma; higher among those with drained volume between 300 and 599 ml. The median hospital lenght of stay was higher among those with empyema.Conclusion:the incidence of PD was 1.83% and RH was 10.63%, these results are consistent with the low severity of the patients involved in this study and consistent with the literature. The incidence of empyema proved to be negatively associated with the occurrence of injury by firearms and positively associated with a drained volume between 300 and 599 ml, compared with lower or higher volumes.