999 resultados para reservoir prediction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several studies have suggested that men with raised plasma triglycerides (TGs) in combination with adverse levels of other lipids may be at special risk of subsequent ischemic heart disease (IHD). We examined the independent and combined effects of plasma lipids at 10 years of follow-up. We measured fasting TGs, total cholesterol (TC), and high density lipoprotein cholesterol (HDLC) in 4362 men (aged 45 to 63 years) from 2 study populations and reexamined them at intervals during a 10-year follow-up. Major IHD events (death from IHD, clinical myocardial infarction, or ECG-defined myocardial infarction) were recorded. Five hundred thirty-three major IHD events occurred. All 3 lipids were strongly and independently predictive of IHD after 10 years of follow-up. Subjects were then divided into 27 groups (ie, 33) by the tertiles of TGs, TC, and HDLC. The number of events observed in each group was compared with that predicted by a logistic regression model, which included terms for the 3 lipids (without interactions) and potential confounding variables. The incidence of IHD was 22.6% in the group with the lipid risk factor combination with the highest expected risk (high TGs, high TC, and low HDLC) and 4.7% in the group with the lowest expected risk (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radical abdominal radiotherapy in men runs the risk of impairing their fertility owing to scattered dose to the testes, outside of the treated volume. In patients for whom this is a concern it is important to be able to predict the dose to the testes before treatment in order to determine whether semen cryopreservation should be undertaken and testicular shielding performed during treatment. Measurements have been made on an anthropomorphic phantom to determine the magnitude of these doses for a four-field treatment consisting of an anterior-posterior parallel pair and a lateral parallel pair. A dataset is presented, which, together with a correction for patients size, allows an estimate of testicular dose to be made given only the photon energy, interfield distances and the distance from the testes to the nearest beam edge. Thermoluminescent dosimetry has been carried out in 17 patients to validate the use of the data tables. The results indicate that testicular doses may be estimated with a standard deviation corresponding to 1%-2% of the tumour dose, which is sufficient for the purpose of determining whether fertility is threatened by a planned treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: Raman spectroscopy has been used for the first time to predict the FA composition of unextracted adipose tissue of pork, beef, lamb, and chicken. It was found that the bulk unsaturation parameters could be predicted successfully [R-2 = 0.97, root mean square error of prediction (RMSEP) = 4.6% of 4 sigma], with cis unsaturation, which accounted for the majority of the unsaturation, giving similar correlations. The combined abundance of all measured PUFA (>= 2 double bonds per chain) was also well predicted with R-2 = 0.97 and RMSEP = 4.0% of 4 sigma. Trans unsaturation was not as well modeled (R-2 = 0.52, RMSEP = 18% of 4 sigma); this reduced prediction ability can be attributed to the low levels of trans FA found in adipose tissue (0.035 times the cis unsaturation level). For the individual FA, the average partial least squares (PLS) regression coefficient of the 18 most abundant FA (relative abundances ranging from 0.1 to 38.6% of the total FA content) was R-2 = 0.73; the average RMSEP = 11.9% of 4 sigma. Regression coefficients and prediction errors for the five most abundant FA were all better than the average value (in some cases as low as RMSEP = 4.7% of 4 sigma). Cross-correlation between the abundances of the minor FA and more abundant acids could be determined by principal component analysis methods, and the resulting groups of correlated compounds were also well-predicted using PLS. The accuracy of the prediction of individual FA was at least as good as other spectroscopic methods, and the extremely straightforward sampling method meant that very rapid analysis of samples at ambient temperature was easily achieved. This work shows that Raman profiling of hundreds of samples per day is easily achievable with an automated sampling system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raman spectroscopy has been used to predict the abundance of the FA in clarified butterfat that was obtained from dairy cows fed a range of levels of rapeseed oil in their diet. Partial least squares regression of the Raman spectra against FA compositions obtained by GC showed good prediction for the five major (abundance >5%) FA with R-2=0.74-0.92 and a root mean SE of prediction (RMSEP) that was 5-7% of the mean. In general, the prediction accuracy fell with decreasing abundance in the sample, but the RMSEP was 1.25%. The Raman method has the best prediction ability for unsaturated FA (R-2=0.85-0.92), and in particular trans unsaturated FA (best-predicted FA was 18:1 tDelta9). This enhancement was attributed to the isolation of the unsaturated modes from the saturated modes and the significantly higher spectral response of unsaturated bonds compared with saturated bonds. Raman spectra of the melted butter samples could also be used to predict bulk parameters calculated from standard analyzes, such as iodine value (R-2=0.80) and solid fat content at low temperature (R-2=0.87). For solid fat contents determined at higher temperatures, the prediction ability was significantly reduced (R-2=0.42), and this decrease in performance was attributed to the smaller range of values in solid fat content at the higher temperatures. Finally, although the prediction errors for the abundances of each of the FA in a given sample are much larger with Raman than with full GC analysis, the accuracy is acceptably high for quality control applications. This, combined with the fact that Raman spectra can be obtained with no sample preparation and with 60-s data collection times, means that high-throughput, on-line Raman analysis of butter samples should be possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of Raman spectroscopy for the determination of meat quality attributes has been investigated using data from a set of 52 cooked beef samples, which were rated by trained taste panels. The Raman spectra, shear force and cooking loss were measured and PLS used to correlate the attributes with the Raman data. Good correlations and standard errors of prediction were found when the Raman data were used to predict the panels' rating of acceptability of texture (R-2 = 0.71, Residual Mean Standard Error of Prediction (RMSEP)% of the mean (mu) = 15%), degree of tenderness (R-2 = 0.65, RMSEP% of mu = 18%), degree of juiciness (R-2 = 0.62, RMSEP% of mu = 16%), and overall acceptability (R-2 = 0.67, RMSEP% of mu = 11%). In contrast, the mechanically determined shear force was poorly correlated with tenderness (R-2 = 0.15). Tentative interpretation of the plots of the regression coefficients suggests that the alpha-helix to beta-sheet ratio of the proteins and the hydrophobicity of the myofibrillar environment are important factors contributing to the shear force, tenderness, texture and overall acceptability of the beef. In summary, this work demonstrates that Raman spectroscopy can be used to predict consumer-perceived beef quality. In part, this overall success is due to the fact that the Raman method predicts texture and tenderness, which are the predominant factors in determining overall acceptability in the Western world. Nonetheless, it is clear that Raman spectroscopy has considerable potential as a method for non-destructive and rapid determination of beef quality parameters.