983 resultados para plasma light propagation
Resumo:
Red light running (RLR) is a problem in the US that has resulted in 165,000 injuries and 907 fatalities annually. In Iowa, RLR-related crashes make up 24.5 percent of all crashes and account for 31.7 percent of fatal and major injury crashes at signalized intersections. RLR crashes are a safety concern due to the increased likelihood of injury compared to other types of crashes. The research team developed this toolbox for practitioners to address RLR crashes. The Four Es—Engineering, Enforcement, Education, and Emergency Response—should be used together to address RLR problems. However, this toolbox focuses on engineering, enforcement, and education solutions. The toolbox has two major parts: Guidelines to identify problem intersections and the causes of RLR at intersections Roadway-based and enforcement countermeasures for RLR
Resumo:
Crashes related to red light running account for more than 800 deaths and thousands of injuries each year in the United States. Many states and local jurisdictions have undertaken studies and enacted programs in reaction to this major transportation safety concern. This research study examined the scope of this phenomenon in Iowa, reviewed red light running reduction studies and programs nationwide, and proposed countermeasures to address significant violation problems.
Resumo:
Background and Objectives: Precursor lesions of oesophagus adenocarcinoma constitute a clinical dilemma. Photodynamic therapy (PDT) is an effective treatment for this indication, but it is difficult to optimise without an appropriate animal model. For this reason, we assessed the sheep model for PDT in the oesophagus with the photosensitiser meta-(tetra-hydroxyphenyl) chlorin (mTHPC). Materials and Methods: Twelve sheep underwent intravenous mTHPC injection, blood sampling and fluorescence measurements. mTHPC's pharmacokinetics was measured in vivo and in plasma by fluorescence spectroscopy. Biopsies of sheep oesophagus were compared to corresponding human tissue, and the mTHPC's biodistribution was studied under fluorescence microscopy. Finally, the sheep oesophageal mucosa was irradiated, 4 days after mTHPC's injection. Results: Histologically, the sheep and human oesophagus were closely comparable, with the exception of additional fatty tissue in the sheep oesophagus. mTHPC's pharmacokinetics in sheep and human plasmas were similar, with a maximum of concentration in the sheep 10 hours after i.v. injection. mTHPC's pharmacokinetics in vivo reached its maximum after 30-50 hours, then decreased to background levels, as in humans under similar conditions. Two days after injection, mTHPC was mainly distributed in the lamina propria, followed by a penetration into the epithelium. The sheep and human tissue sensitivity to mTHPC PDT was similar. Conclusion: In conclusion, this model showed many similarities with humans as to mTHPC's plasma and tissue pharmacokinetics, and for tissue PDT response, making it suitable to optimise oesophagus PDT. Lasers Surg. Med. 41:643-652,2009. (C) 2009Wiley-Liss,Inc.
Resumo:
Report on a special investigation of the New Hampton Municipal Light Plant for the period January 1, 2001 through May 31, 2012
Resumo:
Pentobarbital-anaesthetized male Wistar rats were infused with 6microgkg-1min-1 of noradrenaline. The infusion was supplemented with 8.5 mgkg-1min-1 of D-3-hydroxybutyrate (3-OHB) for 15 min in order to determine its effect on the adrenergic response of the rat. Plasma levels of noradrenaline rose to a plateau of approximately 50 nmoll-1 with infusion. In the group infused with noradrenaline alone, noradrenaline levels were maintained for 1h. Supplementation with 3-OHB induced a decrease in plasma noradrenaline level that was inversely correlated with 3-OHB level. Aortic and interscapular brown adipose tissue temperatures increased with noradrenaline infusion, but the rise was arrested by 3-OHB; replacing 3-OHB with glucose had no effect. Infusion of saline, glucose or 3-OHB in the absence of noradrenaline did not induce a rise in temperature in either tissue. Blood 3-OHB concentration increased to 1.2 mmoll-1 during 3-OHB infusion, decreasing rapidly at the end of infusion. Blood glucose levels increased with noradrenaline infusion; the presence of high 3-OHB levels decreased glucose concentration. The effects observed were transient and dependent on 3-OHB concentration; these effects may help explain most of the other effects of noradrenaline described here. The role of 3-OHB as a regulator of adrenergic responses seems to be part of a complex fail-safe mechanism which prevents wasting.
Resumo:
Conscious female adult lean and obese Zucker rats were injected through the jugular vein with radioactive iodine-labeled murine leptin; in the ensuing 8 min, four blood samples were sequentially extracted from the carotid artery. The samples were used in a modified RIA for leptin, in which paired tubes received the same amount of either labeled or unlabeled leptin, thus allowing us to estimate both leptin levels and specific radioactivity. The data were used to determine the decay curve parameters from which the half-life of leptin (5.46 ± 0.23 min for lean rats and 6.99 ± 0.75 min for obese rats) as well as the size of its circulating pool (32 pmol/kg for lean rats and 267 pmol/kg for obese rats) and the overall degradation rate (96 fkat/kg for lean rats and 645 fkat/kg for obese rats) were estimated. These values are consistent with the hormonal role of leptin and the need for speedy changes in its levels in response to metabolic challenge.