999 resultados para método de extração
Resumo:
Novel and quantitative mass spectrometry methods for rapid and accurate enantiomeric excess determination are presented. These methodologies use electrospray ionization (ESI) and mass spectrometry (MS) to detect and analyze, via collision-induced dissociation (CID), mass-selected transition metal complexes that promote enantio especific interactions. The data from CID are conveniently treated by the kinetic method, a sensitive linear free energy method of treating mass spectrometric results. Four different variations of this methodology are described: single ratio method (S R), quotient ratio method (Q R), fixed ligand method (S Rfixed), and quotient ratio method with fixed ligand (Q Rfixed). These individual methods are compared and their main features discussed in detail.
Resumo:
Malaria is still one of the major diseases in the world, causing physical and economic problems in tropical regions. Artemisinin (Qinghaosu), a natural compound identified in Artemisia annua L. , is an effective drug mainly against cerebral malaria. The action of this drug is immediate and parasitaemia in the treatment of drug-resistant malaria is rapidily reduced, justifying the industrial production of artemisinin. This article focuses on the industrial production of this potent antimalarial drug, including strategies for enhancing yield using inexpensive and easy steps.
Resumo:
This is a review about the use of Blue rayon in the extraction and concentration of environmental contaminants in the aquatic environment. Blue rayon is an adsorbent composed of fibers covalently linked with copper phthalocyanine trisulphonate that has the ability to selectively adsorb polycyclic compounds. Blue rayon can be used in situ, in columns or in flasks. This method showed to be efficient in the extraction of important classes of environmental contaminants like the polycyclic aromatic hydrocarbons (PAHs), aromatic amines and phenylbenzotriazoles (PBTAs) and can be an important tool in monitoring studies for the evaluation of water quality.
Resumo:
This paper presents an easy and practical procedure to obtain silica-based C-8 type sorbents for use in solid-phase extraction. The materials are prepared by depositing poly(methyloctylsiloxane), PMOS, on the silica support. Two different treatments for immobilization were used: thermal treatment or gamma irradiation. Suitable recoveries were obtained after pre-concentration of dilute solutions, at the ng/L level, of a mixture of pesticides, indicating the good performance of the materials.
Resumo:
Residual CuSO4 was incorporated into the mass utilized for cement preparation. To a cement mass with 1:0.5:5 of cement, lime and sand to 0.25, 0.50, 0.75 and 1.00% of residual CuSO4 were added. The sulfate was mixed separately with lime and water to induce metal precipitation. The hardened test bodies were submerged in Milli-Q water for three months. No Cu was detected in the water by Atomic Absorption Spectrometry. The best proportion for mechanical resistance and porosity is 0.50%. The cement is adequate for non-structural objects.
Resumo:
A simple, fast and low-cost methodology was optimized, seeking preparation of a crude pig liver esterase (PLE) concentrate. Basically, the method consisted of the following steps: liver homogenization, acetone washing, enzyme extraction and purification/concentration. Starting from 1 kg of fresh liver more than 200 kU of PLE suspension were obtained after 8 hours, at an estimated cost of US$0.21/kU. The PLE concentrate thus obtained was stable, showing 96-100% of the initial activity after 7 months in refrigerator at 4°C.
Resumo:
The presence of residues of the major groups of pesticides (organohalogen, organophosphorous, pyrethroids and organonitrogen) in representative samples of honey produced in Bauru (state of São Paulo, Brazil) was investigated from 1999 through2004. A multiresidue method was applied to honey samples to determine 48 pesticides with recoveries ranging from 76 to 95%. The limits of detection found were lower than 10 µg/kg for GC-MS-SIM. The results indicated that most pesticides found in the samples belonged to the organohalogen and organonitrogen groups. Residues of malathion were detected in almost all of the samples in high concentration.
Resumo:
In this work a simple and sensitive procedure to extract organic mercury from water and sediment samples, using methylene chloride in acidic media followed by CVAFS quantification has been developed. The method was evaluated for possible interferents, using different inorganic mercury species and humic acid, no effects being observed. The detection limit for organic mercury was 160 pg and 396 pg for water and sediment samples respectively. The accuracy of the method was evaluated using a certified reference material of methylmercury (BCR-580, estuarine sediment). Recovery tests using methylmercury as surrogate spiked with 1.0 up to 30.0 ng L-1 ranged from 90 up to 109% for water samples, whereas for sediments, recoveries ranged from 57 up to 97%.
Resumo:
This work reports extraction yield and chemical characterization of the extracts obtained by high-pressure CO2 extraction of a cultivar of Ocimum basilicum L. The experiments were performed in the temperature range of 20 to 50 °C, from 100 to 250 atm of pressure. Chemical analyses were carried out by gas chromatography coupled to mass spectrometry, permitting to identify 23 compounds that were grouped into five chemical classes. Results showed that temperature and solvent density influenced positively the extraction yield. At 20 °C and 0.41 g cm-3 occurred a rise in the concentration of monoterpenes, oxygenated monoterpenes, sesquiterpenes and oxygenated sesquiterpenes.
Resumo:
Solvent extraction has been successfully applied to metal ion preconcentration and often meant the use of toxic organic diluents. However, regulatory pressure is increasingly focusing on the use and disposal of organic solvents, and thus the development of nonhazardous alternatives is important. In this review, we examine the application of aqueous biphasic systems (ABS) to extraction of ions, analyzing their potential and limitations and suggest that ABSs could be an efficient substitute for oil/water biphasic systems. ABSs are formed by mixing certain inorganic salts and water-soluble polymers, or by mixing two water-soluble polymers.
Resumo:
A rapid and efficient method for the analysis of histamine in wines using HPLC with fluorescence detection after derivatization was developed and validated. The method LOD and LOQ values were 0.25 and 0.50 mg L-1 respectively. The repeatability and intermediary precision for the instrument and for the method presented RSD values of 3.7 and 2.9%, and 6.0 and 5.6%, respectively. The recoveries were 95.5 and 89.9% for the fortification levels of 2 and 10 mg L-1. The method was applied to determine the histamine content in Cabernet Sauvignon wines, which presented values between 1.2 and 5.7 mg L-1.
Resumo:
The validation of analytical methods was carried out for di-(ethylhexyl) phthalate (DEHP) and adipate (DEHA) the determination of in PVC films. The level of DEHP and DEHA in samples was determined by leaving the film in contact with n-heptane during 48 hours and analysis in a gas chromatograph (GC) equipped with a flame ionization detector and fused silica column with 5% phenylmethyl silicone in the dimensions 30 m x 0.53 mm x 2.65 mm. The results for detection and the quantification limits were smaller than the restriction limits. The recovery rates of DEHP and DEHA were, respectively, 69.10 and 75.30 %.
Resumo:
A new titrimetric method for the determination of phosphite in fertilizer samples, based on reaction of H3PO3 with standard iodine solution in neutral media, is proposed. Diluted samples containing ca. 0.4% m/v P2O5 are heated and titrated with 0.05 mol L-1 iodine standard until the solution becomes faint yellow. Back titration is also feasible: a slight excess of titrant is added followed by starch indicator and titration is completed taking as the end point the change in color from blue to colorless. The influence of chemical composition and pH of buffers, temperature and foreign species on waiting time and end-point detection were investigated. For the Na2HPO4/NaH2PO4 buffer (pH 6.8) at 70 °C, the titration time was 10 min, corresponding to about 127 mg iodine, 200 mg KI and 174 mg Na2HPO4 and 176 mg NaH2PO4 consumed per determination. Accuracy was checked for phosphite determination in seven fertilizer samples. Results obtained by the proposed procedure were in agreement with those obtained by spectrophotometry at 95% confidence level. The R.S.D. (n=10) for direct and back titration was 0.4% and 1.3% respectively.
Resumo:
La presente solicitud de patente tiene por objeto un dispositivo y método para medir magnitudes eléctricas de sensores analógicos, que 10 incorpora notables innovaciones y ventajas.La presente invención se refiere, en general, a los sistemas de medida de sensores analógicos, incluidos aquellos que generan directamente una corriente o una tensión eléctrica.
Resumo:
The liquid-liquid extraction with the low temperature partition technique was developed for the analysis of four pyrethroids in water by CG. Using a factorial design the extraction technique was optimised evaluating the effect of the variables ionic strength, contact time and proportion between sample and solvent volumes. The validation parameters sensitivity, precision, accuracy and detection and quantification limits were evaluated. The LOD and LOQ of the method varied from 1.1 to 3.2 µg L-1 and 2.7 to 9.5 µg L-1, respectively.