981 resultados para hip joint


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The compounds chlorothiazide and hydrochlorothiazide (crystalline form II) have been studied in their fully hydrogenous forms by powder neutron diffraction on the GEM diffractometer. The results of joint Rietveld refinement of the structures against multi-bank neutron and single-bank X-ray powder data are reported and show that accurate and precise structural information can be obtained from polycrystalline molecular organic materials by this route.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a new iterative algorithm for OFDM joint data detection and phase noise (PHN) cancellation based on minimum mean square prediction error. We particularly highlight the problem of "overfitting" such that the iterative approach may converge to a trivial solution. Although it is essential for this joint approach, the overfitting problem was relatively less studied in existing algorithms. In this paper, specifically, we apply a hard decision procedure at every iterative step to overcome the overfitting. Moreover, compared with existing algorithms, a more accurate Pade approximation is used to represent the phase noise, and finally a more robust and compact fast process based on Givens rotation is proposed to reduce the complexity to a practical level. Numerical simulations are also given to verify the proposed algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improving admittance of robotic joints is the key issue for making rehabilitation robots safe. This paper describes a design of Redundant Drive Joint (RD-Joint) which allows greater flexibility in the design of robotic mechanisms. The design strategy of the RD-Joint employs a systematic approach which consists of 1) adopting a redundant joint mechanism with internal kinematical redundancy to reduce effective joint inertia, and 2) adopting an adjustable admittance mechanism with a novel Cross link Reduction Mechanism and mechanical springs and dampers as a passive second actuator. First, the basic concepts used to construct the redundant drive joint mechanism are explained, in particular the method that allows a reduction in effective inertia at the output joint. The basic structure of the RD-Joint is introduced based on the idea of reduced inertia along with a method to include effective stiffness and damping. Then, the basic design of the adjustable admittance mechanism is described. Finally, a prototype of RD-joint is described and its expected characteristics are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a proposed admittance enhanced redundant joint mechanism (AERJM) which allows greater flexibility in the design of robotic joints. First, the basic concept of a redundant joint mechanism that reduces joint inertia is explained. Second, the AERJM structure is discussed. AERJM consists of a redundancy introducing mechanism (RIM), the adjustable admittance mechanism (AAM) and an admittance enhancing actuator. The working principles of the AERJM concept are analysed. The design and a working prototype, consisting of a variable reduction mechanism, along with a spring and a damper with constant coefficients, are described.