999 resultados para dental veneer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ?3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In published studies, it has been suggested that dental wear is associated with gastroesophageal reflux disease (GERD). This systematic review was carried out to evaluate the association of GERD, dental erosion, and halitosis and to compare the indices adopted in epidemiological surveys. The Medline database (until October, 2011) was searched systematically to identify studies evaluating the prevalence of oral alterations, such as dental erosion and halitosis, in patients with GERD symptoms. Two reviewers analyzed all reports and the selected studies were evaluated according to the quality of evidence, using the validated Newcastle–Ottawa Quality Assessment Scale. Full-text copies of a total of 32 publications were obtained in duplicate. Sixteen publications were identified among the citations in the Bibliographic lists of studies that fulfilled the exclusion/inclusion criteria and quality of evidence. The relationship between dental erosion and GERD patients was significant in only seven studies. According to three studies, halitosis could be one of several extraesophageal symptoms or manifestations in GERD patients. In one study, it was found that the mucosa of GERD patients was significantly more acidic in comparison with that of the control group. This systematic review showed that there is a relationship between GERD and oral diseases (dental erosion and halitosis). The epidemiological surveys used different indices to analyze GERD and dental erosion. Further research could investigate the best method for assessing the two diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem: Since the introduction of glass fiber posts, irreversible vertical root fractures have become a rare occurrence; however, adhesive failure has become the primary failure mode. Purpose: The purpose of this study was to evaluate the push-out bond strength of glass fiber posts cemented with different luting agents on 3 segments of the root. Material and methods: Eighty human maxillary canines with similar root lengths were randomly divided into 8 groups (n=10) according to the cement assessed (Rely X luting, Luting and Lining, Ketac Cem, Rely X ARC, Biscem, Duo-link, Rely X U100, and Variolink II). After standardized post space preparation, the root dentin was pretreated for dualpolymerizing resin cements and untreated for the other cements. The mixed luting cement paste was inserted into post spaces with a spiral file and applied to the post surface that was seated into the canal. After 7 days, the teeth were sectioned perpendicular to their long axis into 1-mm-thick sections. The push-out test was performed at a speed of 0.5 mm/min until extrusion of the post occurred. The results were evaluated by 2-way ANOVA and the all pairwise multiple comparison procedures (Tukey test) (?=.05). Results: ANOVA showed that the type of interaction between cement and root location significantly influenced the push-out strength (P<.05). The highest push-out strength results with root location were obtained with Luting and Lining (S3) (19.5 ±4.9 MPa), Ketac Cem (S2) (18.6 ±5.5 MPa), and Luting and Lining (S1) (18.0 ±7.6 MPa). The lowest mean values were recorded with Variolink II (S1) (4.6 ±4.0 MPa), Variolink II (S2) (1.6 ±1.5 MPa), and Rely X ARC (S3) (0.9 ±1.1 MPa). Conclusions: Self-adhesive cements and glass ionomer cements showed significantly higher values compared to dual-polymerizing resin cements. In all root segments, dual-polymerizing resin cements provided significantly lower bond strength. Significant differences among root segments were found only for Duo-link cement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The prevalence and severity of tooth wear and dental erosion is rising in children and there is no consensus about an index to be employed. Aim: To assess the reliability of an epidemiological scoring system dental wear index (DWI) to measure tooth wear and dental erosive wear. Design: An epidemiological cross-sectional survey was conducted to evaluate and compare tooth wear and dental erosion using the dental wear index and erosion wear index (EWI). The study was conducted with randomised samples of 2,371 children aged between 4 years and 12 years selected from the State of São Paulo, Brazil. Records were used for calculating tooth wear and dental erosion; the incisal edge and canine cusp were excluded. Results: As the schoolchildren's ages increased the severity of primary tooth wear increased in canines (P = 0.0001, OR = 0.34) and molars (P = 0.0001, OR = 2.47) and erosion wear increased in incisal/occlusal (P = 0.0001, OR = 5.18) and molars (P = 0.0001, OR = 2.47). There was an increased prevalence of wear in the permanent teeth of older schoolchildren, particularly on the incisal/occlusal surfaces (P = 0.0001, OR = 7.03). Conclusion: The prevalence of tooth wear and dental erosion increased as age increased in children. The epidemiological scoring system Dental Wear Index is able to measure both tooth wear and dental erosive wear. This index should be used to monitor the progression of non-carious lesions and to evaluate the levels of disease in the population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to compare the production of the chemokines CCL3 and CXCL12 by cultured dental pulp fibroblasts from permanent (PDPF) and deciduous (DDPF) teeth under stimulation by Porphyromonas gingivalis LPS (PgLPS). Material and Methods: Primary culture of fibroblasts from permanent (n=3) and deciduous (n=2) teeth were established using an explant technique. After the fourth passage, fibroblasts were stimulated by increasing concentrations of PgLPS (0 – 10 µg/mL) at 1, 6 and 24 h. The cells were tested for viability through MTT assay, and production of the chemokines CCL3 and CXCL12 was determined through ELISA. Comparisons among samples were performed using One-way ANOVA for MTT assay and Two-way ANOVA for ELISA results. Results: Cell viability was not affected by the antigen after 24 h of stimulation. PgLPS induced the production of CCL3 by dental pulp fibroblasts at similar levels for both permanent and deciduous pulp fibroblasts. Production of CXCL12, however, was significantly higher for PDPF than DDPF at 1 and 6 h. PgLPS, in turn, downregulated the production of CXCL12 by PDPF but not by DDPF. Conclusion: These data suggest that dental pulp fibroblasts from permanent and deciduous teeth may present a differential behavior under PgLPS stimulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to evaluate the influence of thermal and mechanical cycling and veneering technique on the shear bond strength of Y-TZP (yttrium oxide partially stabilized tetragonal zirconia polycrystal) core–veneer interfaces. Materials and methods: Cylindrical Y-TZP specimens were veneered either by layering (n = 20) or by pressing technique (n = 20). A metal ceramic group (CoCr) was used as control (n = 20). Ten specimens for each group were thermal and mechanical cycled and then all samples were subjected to shear bond strength in a universal testing machine with a 0.5 mm/min crosshead speed. Mean shear bond strength (MPa) was analysed with a 2-way analysis of variance and Tukey’s test ( p < 0.05). Failure mode was determined using stereomicroscopy and scanning electron microscopy (SEM). Results: Thermal and mechanical cycling had no influence on the shear bond strength for all groups. The CoCr group presented the highest bond strength value ( p < 0.05) (34.72 7.05 MPa). There was no significant difference between Y-TZP veneered by layering (22.46 2.08 MPa) or pressing (23.58 2.1 MPa) technique. Failure modes were predominantly adhesive for CoCr group, and cohesive within veneer for Y-TZP groups. Conclusions: Thermal and mechanical cycling, as well as the veneering technique does not affect Y-TZP core–veneer bond strength. Clinical significance: Different methods of veneering Y-TZP restorations would not influence the clinical performance of the core/veneer interfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The decision-making process for the treatment of esthetic areas is based on the achievement of a healthy, harmonious, and pleasant smile. These conditions are directly associated with a solid knowledge of tooth anatomy and proportions, as well as the smile line, soft tissue morphology, and osseous architecture. To achieve these objectives, a multidisciplinary approach may be necessary to create long-term harmony between the final restoration and the adjacent teeth, and the health of the surrounding soft and hard tissues. This case report describes the application of a minimally invasive therapy on a 33-year-old woman seeking esthetic treatment. Minimally invasive periodontal plastic surgery associated with porcelain laminate veneers yielded satisfactory esthetics and minimal trauma to dental and periodontal tissues. Such a combined approach may be considered a viable option for the improvement of "white" and "red" esthetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As várias opções para a realização de tratamentos estéticos conservadores permitem ao profissional a escolha de materiais e técnicas apropriados, que melhor se enquadrem nas características individuais de cada paciente e na realidade de seu consultório. No caso clínico apresentado, a técnica de clareamento dental em consultório com peróxido de hidrogênio a 35% (Total Blanc Office, DFL), ativado com luz híbrida LED/LASER e a microabrasão de esmalte com pasta de acido fosfórico a 37% e pedra pomes, foram associados. Os resultados com o clareamento em consultório são imediatos, de forma que o profissional dispõe de total controle sobre aplicação do gel clareador em áreas e dentes específicos. A microabrasão do esmalte é um tratamento simples e custo relativamente baixo, remove as manchas superficiais do esmalte com preservação de estrutura dental. No caso apresentado, a associação das duas técnicas proporcionou a obtenção de excelente resultado estético em apenas uma sessão de atendimento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To test the hypothesis that the difference in the coefficient of thermal contraction of the veneering porcelain above (˛liquid) and below (˛solid) its Tg plays an important role in stress development during a fast cooling protocol of Y-TZP crowns. Methods. Three-dimensional finite element models of veneered Y-TZP crowns were developed. Heat transfer analyses were conducted with two cooling protocols: slow (group A) and fast (groups B–F). Calculated temperatures as a function of time were used to determine the thermal stresses. Porcelain ˛solid was kept constant while its ˛liquid was varied, creating different ˛/˛solid conditions: 0, 1, 1.5, 2 and 3 (groups B–F, respectively). Maximum ( 1) and minimum ( 3) residual principal stress distributions in the porcelain layer were compared. Results. For the slowly cooled crown, positive 1 were observed in the porcelain, orientated perpendicular to the core–veneer interface (“radial” orientation). Simultaneously, negative 3 were observed within the porcelain, mostly in a hoop orientation (“hoop–arch”). For rapidly cooled crowns, stress patterns varied depending on ˛/˛solid ratios. For groups B and C, the patterns were similar to those found in group A for 1 (“radial”) and 3 (“hoop–arch”). For groups D–F, stress distribution changed significantly, with 1 forming a “hoop-arch” pattern while 3 developed a “radial” pattern. Significance. Hoop tensile stresses generated in the veneering layer during fast cooling protocols due to porcelain high ˛/˛solid ratio will facilitate flaw propagation from the surface toward the core, which negatively affects the potential clinical longevity of a crown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background The presence of traumatic dental injuries and malocclusions can have a negative impact on quality of life of young children and their parents, affecting their oral health and well-being. The aim of this study was to assess the impact of traumatic dental injuries and anterior malocclusion traits on the Oral Health-Related Quality of Life (OHRQoL) of children between 2 and 5 years-old. Methods Parents of 260 children answered the six domains of the Early Childhood Oral Health Impact Scale (ECOHIS) on their perception of the OHRQoL (outcome). Two calibrated dentists assessed the types of traumatic dental injuries (Kappa = 0.9) and the presence of anterior malocclusion traits (Kappa = 1.0). OHRQoL was measured using the ECOHIS. Poisson regression was used to associate the type of traumatic dental injury and the presence of anterior malocclusion traits to the outcome. Results The presence of anterior malocclusion traits did not show a negative impact on the overall OHRQoL mean or in each domain. Only complicated traumatic dental injuries showed a negative impact on the symptoms (p = 0.005), psychological (p = 0.029), self image/social interaction (p = 0.004) and family function (p = 0.018) domains and on the overall OHRQoL mean score (p = 0.002). The presence of complicated traumatic dental injuries showed an increased negative impact on the children's quality of life (RR = 1.89; 95% CI = 1.36, 2.63; p < 0.001). Conclusions Complicated traumatic dental injuries have a negative impact on the OHRQoL of preschool children and their parents, but anterior malocclusion traits do not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the general alloy composition. Regarding the alloys containing nickel, the Ni-Cr and Ni-Cr-Ti alloys released 0.62 mg/L of Ni on average, while the Co-Cr dental alloy released ions between 0.01 and 0.03 mg/L of Co and Cr, respectively.The open-circuit potential stabilized at a higher level with lower deviation (standard deviation: Ni-Cr-6Ti = 32 mV/SCE and Co-Cr = 54 mV/SCE). The potenciodynamic curves of the dental alloys showed that the Ni-based dental alloy with >70 wt% of Ni had a similar curve and the Co-Cr dental alloy showed a low current density and hence a high resistance to corrosion compared with the Ni-based dental alloys. Some changes in microstructure were observed and this fact influenced the corrosion behavior for the alloys. The lower corrosion resistance also led to greater release of nickel ions to the medium. The quantity of Co ions released from the Co-Cr-Mo alloy was relatively small in the solutions. In addition, the quantity of Cr ions released into the artificial saliva from the Co-Cr alloy was lower than Cr release from the Ni-based dental alloys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the correlation between the morphology of the mandibular dental arch and the maxillary central incisor crown. Cast models from 51 Caucasian individuals, older than 15 years, with optimal occlusion, no previous orthodontic treatment, featuring 4 of the 6 keys to normal occlusion by Andrews (the first being mandatory) were observed. The models were digitalized using a 3D scanner, and images of the maxillary central incisor and mandibular dental arch were obtained. These were printed and placed in an album below pre-set models of arches and dental crowns, and distributed to 12 dental surgeons, who were asked to choose which shape was most in accordance with the models and crown presented. The Kappa test was performed to evaluate the concordance among evaluators while the chi-square test was used to verify the association between the dental arch and central incisor morphology, at a 5% significance level. The Kappa test showed moderate agreement among evaluators for both variables of this study, and the chi-square test showed no significant association between tooth shape and mandibular dental arch morphology. It may be concluded that the use of arch morphology as a diagnostic method to determine the shape of the maxillary central incisor is not appropriate. Further research is necessary to assess tooth shape using a stricter scientific basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated by an in vitro model the effect of beverages on dental enamel previously subjected to erosive challenge with hydrochloric acid. The factor under study was the type of beverage, in five levels: Sprite® Zero Low-calorie Soda Lime (positive control), Parmalat® ultra high temperature (UHT) milk, Ades® Original soymilk, Leão® Ice Tea Zero ready-to-drink low-calorie peach-flavored black teaand Prata® natural mineral water (negative control). Seventy-five bovine enamel specimens were distributed among the five types of beverages (n=15), according to a randomized complete block design. For the formation of erosive wear lesions, the specimens were immersed in 10 mL aqueous solution of hydrochloric acid 0.01 M for 2 min. Subsequently, the specimens were immersed in 20 mL of the beverages for 1 min, twice daily for 2 days at room temperature. In between, the specimens were kept in 20 mL of artificial saliva at 37ºC. The response variable was the quantitative enamel microhardness. ANOVA and Tukey's test showed highly significant differences (p<0.00001) in the enamel exposed to hydrochloric acid and beverages. The soft drink caused a significantly higher decrease in microhardness compared with the other beverages. The black tea caused a significantly higher reduction in microhardness than the mineral water, UHT milk and soymilk, but lower than the soft drink. Among the analyzed beverages, the soft drink and the black tea caused the most deleterious effects on dental enamel microhardness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and another of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the original component of the same brand as the implant was positioned, interchangeability was considered valid. Data were compared with the Kruskal-Wallis test at 5% significance level. Some degree of misfit was observed in all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6-16.9 µm, with a 4.6 µm median; and the former from 0.3-12.9 µm, with a 3.4 µm median. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for SIN and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aiming to compare the effect of different light sources for dental bleaching on vascular permeability of dental pulps, forty-eight incisors were used. The bleaching agent (35 % hydrogen peroxide) was activated by halogen light; LED (Light Emitting Diode) or LED, followed by laser phototherapy (LPT) (λ = 780 nm; 3 J/cm²). After the bleaching procedures, the animals received an intra-arterial dye injection and one hour later were sacrificed. The teeth were diaphanized and photographed. The amount of blue stain content of each dental pulp was quantified using a computer imaging program. The data was statistically compared (p < 0.05). The results showed a significant higher (p < 0.01) dye content in the groups bleached with halogen light, compared with the control, LED and LED plus LPT groups. Thus, tooth bleaching activated by LED or LED plus LPT induces lesser resulted in increased vascular permeability than halogen light.