987 resultados para dental prosthesis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This randomized clinical trial sought to evaluate the performance of two packable composites over a period of 36 months. A total of 39 Class I and II restorations were placed in the permanent teeth of 20 patients. Using United States Public Health Services criteria, two investigators evaluated the restorations immediately after placement and again after 12 and 36 months, examining color match, marginal discoloration, marginal integrity, recurrent caries, proximal contact, anatomical shape, surface texture, and postoperative sensitivity. It was concluded that the packable composites evaluated showed satisfactory clinical performance after three years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of ICDAS training in a group of dental students for occlusal caries detection in permanent teeth. Premolars and molars (N=104) with occlusal surfaces varying from ICDAS scores 0 to 6 were cleaned, one occlusal site per tooth was selected, and a photograph taken to identify the site. Eight senior dental students examined the teeth twice with a one-week interval between examinations during each of two phases: before and after the ICDAS e-learning program. Teeth were histologically assessed for caries extension. Intraclass correlation coefficients for intra- and interexaminer repeatability were high, both before (0.75 and 0.72, respectively) and after e-learning (0.82 and 0.78, respectively). The ICDAS scores decreased significantly from before to after e-learning (p=0.0001). Correlation between ICDAS scores and histology scores was moderate (0.57 before e-learning and 0.61 after). Although the ROC curve shows an improvement in the use of the ICDAS scoring after e-learning, the difference was not significant (p=0.10). Specificity of the ICDAS scores significantly improved after e-learning (77 percent vs. 36 percent), and sensitivity was reduced slightly after e-learning (87 percent vs. 92 percent). The ICDAS e-learning program improved the performance of the diagnostic skills of the investigated students for the detection of occlusal caries lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the treatment with corticosteroid/antibiotic dressing in pulpotomy with calcium hydroxide. Methods: Forty-six premolars were pulpotomized and randomly assigned into 3 groups. In Group I pulpal wound was directly capped with calcium hydroxide, and Group II and Group III received corticosteroid/antibiotic dressing for 10 min or 48 h, respectively, before pulp capping. Teeth were processed for histological analysis after 7, 30 or 60 days to determine inflammatory cell response, tissue disorganization, dentin bridge formation and presence of bacteria. Attributed scores were analyzed by Kruskal-Wallis and Mann-Whitney tests (α=0.05). Results: On the 7th day, all groups exhibited dilated and congested blood vessels in the tissue adjacent to pulpal wound. The inflammatory cell response was significantly greater in Group III (p<0.05). On the 30th day, in all groups, a thin dentin matrix layer was deposited adjacent to the pulpal wound and a continuous odontoblast-like cell layer underlying the dentin matrix was observed. On the 60th day, all groups presented a thick hard barrier characterized by an outer zone of dystrophic calcification and an inner zone of tubular dentin matrix underlined by a defined odontoblast-like cell layer. Conclusions: Within the limitations of present study, considering that the treatment was performed in healthy teeth, it may be concluded that the use of a corticosteroid/antibiotic dressing before remaining tissue protection with calcium hydroxide had no influence on pulp tissue healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To investigate: a) caries experience in 5 year-old children and its relationship to the caries risk evaluation made before 1 year of age; b) compliance of parents to an infant oral health program as well as the abandonment reasons. Methods: Group A (GA) - 242 children (60-71 months old) who stayed in the program and had been enrolled since their first year of life underwent a clinical examination according to the WHO's criteria; their parents/caregivers were interviewed to ascertain their compliance to the program. Group B (GB) - parents of 60 children, who had dropped out of the program, were interviewed to check the reasons of withdrawing. The caries risk classification was based on the file at the first appointment. Chi-square test was used (α=0.05) for statistical analyses. Results: Most of the children were free of caries (71.1%). Caries risk evaluation showed low sensibility (34.3%, 95% CI = 22.4-46.1) and high specificity (74.4%, 95% CI = 67.6-81.2) to caries experience. Sixty-two mothers (25.6%) reported difficulty to follow the guidelines. The main reason for dropping out was changing to similar health services (40.0%). Conclusions: Caries risk in the first year of life was not efficient to predict dental caries experience at 5 years of age. Educational practice should be improved to increase the compliance of the parents to the program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an individual designing prosthesis for surgical use and proposes a methodology for such design through mathematical extrapolation of data from digital images obtained via tomography of individual patient's bones. Individually tailored prosthesis designed to fit particular patient requirements as accurately as possible should result in more successful reconstruction, enable better planning before surgery and consequently fewer complications during surgery. Fast and accurate design and manufacture of personalized prosthesis for surgical use in bone replacement or reconstruction is potentially feasible through the application and integration of several different existing technologies, which are each at different stages of maturity. Initial case study experiments have been undertaken to validate the research concepts by making dimensional comparisons between a bone and a virtual model produced using the proposed methodology and a future research directions are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the development of an multi-projection stereoscopic dental arches application with semantic descriptions. The first section presents the concepts of the used technologies. Applications and examples are demonstrated. Finally, is presented the physical structure and the developed system, where a 3D dental arch is used as a model and can be viewed in multi-projection, thereby, providing greater user's immersion. ©2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the effect of 10% and 16% carbamide peroxide bleaching agents on the surface microhardness of micro-particulate feldspathic ceramics (VM7 and VM13, Vita Zahnfabrik). Forty specimens (8-mm diameter, 2-mm thickness) were divided into four groups (n=10): GI-VM7 + 10% Whiteness, G2-VM7 + 16% Whiteness, G3-VM13 + 10% and G4-VM13 + 16% Whiteness. The home-use bleaching agents were applied for 8 hours on 15 days, and the specimens were stored in distilled water at 37 degrees C. The Vickers hardness number (HV) was determined for each specimen. Data were analyzed by the Wilcoxon and Mann-Whitney tests (p < 0.05). The microhardness values before exposure were: g1-433 (57); g2-486 (22); g3-509 (28); g4-518 (24), and after exposure: G1-349 (32); G2-496 (95); G3-519 (38); G4-502 (81). G2 exhibited a higher and significant difference than GI in VM7 groups, and the effect of bleaching concentration was shown to be significant by the Mann-Whitney test. And for VM13, both the Wilcoxon and Mann-Whitney tests showed no significant differences. When using 10% carbamide peroxide, the microhardness of VM7 ceramic was affected, and there were no effect on the microhardness between VM7 and VM13 ceramics when 16% carbamide peroxide was used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Nowadays, research on orthopedic and dental implants is focused on titanium alloys for their mechanical properties and corrosion resistance in the human body environment. Another important aspect to be investigated is their surface topography, which is very important to osseointegration. With laser beam irradiation for roughening the implants surface an easier control of the microtopography is achieved, and surface contamination is avoided. The aim of this study was to assess human bone marrow stem cells response to a newly developed titanium alloy, Ti-15Mo, with surface topography modified by laser beam irradiation. Materials and methods: A total of 10 Ti machined disks (control), 10 Ti-15Mo machined disks and 10 Ti-15Mo disks treated by laser beam-irradiation were prepared. To study how Ti-15Mo surface topografy can induce osteoblast differentiation in mesenchymal stem cells, the expression levels of bone related genes and mesenchymal stem cells marker were analyzed, using real time Reverse Transcription-Polymerase Chain Reaction. Results: In Test 1 (comparison between Ti-15Mo machined disks and Ti-machined disks) quantitative real-time RT-PCR showed a significant induction of ALPL, FOSL1 and SPP1, which increase 20% or more. In Test 2 (comparison between Ti-15Mo laser treated disks and Ti-machined disks) all investigated genes were up-regulated. By comparing Test 1 and Test 2 it was detected that COL1A1, COL3A1, FOSL1 and ENG sensibly increased their expression whereas RUNX2, ALPL and SPP1 expression remained substantially unchanged. Conclusion: The present study demonstrated that laser treated Ti-15Mo alloys are promising materials for implants application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the influence of the grain size coating and shaft angulation of ultrasonic and high-speed diamond burs on the dental cutting effectiveness. Materials and Methods: For the grain size evaluation, cavities were prepared on 40 incisors using high-speed (1092 and 1093F KG Sorensen®) and ultrasonic tips (8.2142 and 6.2142-CVDentus®). For the shaft angulation evaluation, cavities were prepared on 40 incisors using uniangulated (T1-CVDentus®) and biangulated (T1-A CVDentus®) ultrasonic tips. The cavities were bisected and examined at 50 magnification. The width and depth of cavities were measured by Leica QWin software. Kruskal-Wallis non-parametric test was used for analysis. Results: The grain size did not affect the cutting effectiveness, but the high-speed burs promoted deeper and wider cavities than the ultrasonic tips. The shaft angulation did not affect the cutting effectiveness; both the angulated and biangulated tips had greater cutting efficiency in dentin than in enamel. Conclusions: Ultrasonic tips promoted more conservative preparations and seemed promising for cavity preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of platelet rich plasma (PRP) associated to bovine inorganic bone (Bio-Oss®; Geistlich) or bioactive glass (Bio-Gran®; Orthovita, Implant Innovations) on bone healing. Bone cavities were prepared in both sides of the mandible of 4 adult male dogs. The cavities were divided into 4 groups according to the filling material as follows: control, PRP, PRP/Bio-Oss, PRP/Bio-Gran. The animals were sacrificed after 120 days and histological and histomorphometrical analysis was performed. The control group showed 80.6% of bone formation in the longitudinal sections at 6 mm depth and 83.7% at 13 mm depth. The transverse sections displayed 74.2% at both 6 and 13 mm depths. The PRP group showed 21.1% of bone formation in the longitudinal sections at 6 mm depth, and 23.1% at 13 mm depth. The transverse sections presented 28.98% of bone formation at 6 mm depth and 41.2% at 13 mm depth. The PRP/Bio-Gran group showed 25.1% of bone formation in the longitudinal sections at 6 mm depth and 30.4% at 13 mm depth. In the transverse sections, the bone formation was 43.0% at 6 mm depth and 39.7% at 13 mm depth. The PRP/Bio-Oss group showed 35.5% of bone formation in the longitudinal sections at 6 mm depth and 42% at 13 mm depth. In the transversal sections, the bone formation was 26.8% and 31.2% at the depths of 6 and 13 mm, respectively. PRP alone or associated with bovine inorganic bone or bioglass had no significant effect in bone healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to examine the effect of different acid etching times on the surface roughness and flexural strength of a lithium disilicate-based glass ceramic. Ceramic bar-shaped specimens (16 mm x 2 mm x 2 mm) were produced from ceramic blocks. All specimens were polished and sonically cleaned in distilled water. Specimens were randomly divided into 5 groups (n=15). Group A (control) no treatment. Groups B-E were etched with 4.9% hydrofluoric acid (HF) for 4 different etching periods: 20 s, 60 s, 90 s and 180 s, respectively. Etched surfaces were observed under scanning electron microscopy. Surface profilometry was used to examine the roughness of the etched ceramic surfaces, and the specimens were loaded to failure using a 3-point bending test to determine the flexural strength. Data were analyzed using one-way ANOVA and Tukey's test (α=0.05). All etching periods produced significantly rougher surfaces than the control group (p<0.05). Roughness values increased with the increase of the etching time. The mean flexural strength values were (MPa): A=417 ± 55; B=367 ± 68; C=363 ± 84; D=329 ± 70; and E=314 ± 62. HF etching significantly reduced the mean flexural strength as the etching time increased (p=0.003). In conclusion, the findings of this study showed that the increase of HF etching time affected the surface roughness and the flexural strength of a lithium disilicate-based glass ceramic, confirming the study hypothesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the effects of thermal cycling on the microtensile shear bond strength of a self-etching and a conventional pit and fissure sealants to dental enamel. Material and Method: Twenty-four healthy human molars extracted for orthodontic reasons, were sectioned in the mesio-distal direction and divided into two groups (n=24) according to the sealant to be applied: GI - conventional sealant Climpro (3M/ESPE) and GII - self-etching sealant Enamel Loc (Premier Dental). The sealants were applied on flattened enamel in matrixes 1 mm in diameter, in accordance with the manufacturers' recommendations. The specimens were stored in distilled water at 37°C for 24 hours. After this, half the samples of both groups were submitted to 500 thermal cycles in 30s baths at temperatures between 5 and 55°C. Forty-eight hours after the samples were made, the microtensile shear test was performed in an Instron 4411 test machine, with a stainless steel wire with a cylindrical cross section of 0.2mm in diameter at a constant speed of 0.5mm/s. The bond strength values were submitted to ANOVA for 2 factors and the fracture patterns were examined under an optical microscope at 65X magnification. Results: Thermal cycling did not influence the bond strength of the two sealants. The conventional sealant Climpro presented a statistically higher microtensile shear bond strength (11.72MPa, 11.34MPa with and without cycling, respectively) than the self-etching sealant Enamel Loc (5.92MPa, 5.02MPa with and without cycling, respectively). Fracture pattern analysis showed the occurrence of 100% of adhesive failures for Enamel Loc, while the conventional sealant Climpro presented 95% of adhesive failures and 5% of mixed failures. Conclusion: The conventional sealant presented higher microtensile shear bond strength to dental enamel in comparison with the self-etching sealant. Thermal cycling did not affect the bond strength of the sealants used in this study. © 2011 Nova Science Publishers, Inc.