1000 resultados para degassing temperature


Relevância:

20.00% 20.00%

Publicador:

Resumo:

MELECON 2012 - 2012 16th IEEE Mediterranean Electrotechnical Conference, 25 Mar - 28 Mar 2012, Túnez

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN]Most of the information indicating ageing improves tenderness has been collected on the loin and rib-eye muscles over relatively short ageing times, assuming that all muscles will react similarly. In the present study, the effect of extended ageing times on instrumental texture (56 d) and sensory characteristics (42 d) of six different beef sub-primals [striploin (SL), inside round (IR), outside round (OR), eye of round (ER), blade eye (BE) and chuck tender (CT)] was studied. The effects of two ageing temperatures (1and 58C) were also compared. In general, ageing increased tenderness (P<0.05) of SL, BE, ER and CT sub-primals, although BE shear force increased after 42 d of ageing. On the other hand, ageing had no effect on IR tenderness (P<0.05) and resulted in a decrease in tenderness of OR (P<0.05) until day 35, with a later increase after 42 d of ageing. Increasing ageing temperature (58C) had limited effect on tenderness, but ageing time and temperature increases led to lower flavour and higher off-flavour intensity (P<0.05) of the studied sub-primals. These results suggest that cutspecific maximum ageing times and rigid adherence to temperature maximums would be of benefit to optimize postslaughter processes and meat quality

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In consecutive greenhouse studies, growth and propagule formation were examined first in monoecious hydrilla [Hydrilla verticillata (L.f.) Royle], then in dioecious hydrilla, at three temperature levels (25, 30, and 35 C) and contrasted over three periods of growth (8, 12 and 16 wks). Each biotype was grown under natural photoperiods, decreasing from 14 hrs (in Oct, Nov, and Dec). For both biotypes, total biomass and root-to-shoot ratios were significantly reduced at 35 C; greater biomass was produced both at 25 and 30C. Increases in growth period generally enhanced total biomass and shoot production; however, shoot length was unresponsive to growth periods beyond 8 wks. The 35C treatment strongly impeded tuber formation and eliminat4ed the production of axillary turions; the number and biomass of these propagules peaked at lower temperatures under short photoperiods after 12 to 16 wks. Shoot elongation was stimulated with increases in temperature and was especially pronounced in the dioecious biotype. Notably, in the monoecious biotype, the number of shoots as a potential source of fragments, and tuber production (although reduced) occurred at relatively high levels under unfavorably hihg-temperature (35C) conditions. These results suggest that monoecious hydrilla may be better adapted to high temperatures than previously shown, and that the distribution of both biotypes in the U.S. could overlap further in southern states.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared seasonal changes in Eurasian watermilfoil (Myriophyllum spicatum L.) characteristics and water temperature for a shallow poind in Davis, CA, and the Truckee River, near Tahoe City, CA. Tissue C and N were 15% lower in plants from the Truckee River than in plants from the Davis pond. Seasonal fluctuations in tissue N were also different. Mean phenolic acid content of Truckee River palnts (162yM g-1) was less than those from the shallow pond (195 yM g-1). Phenolic acid content was positively related to tissue C for Truckee River and Davis pond plants and, tissue C:N ratio for Truckee River plants. Mean monthly water temperature (1990 to 1998) for the Truckee River site was less than 20 C. Water temperatures were warmer in August and September at this site. However, Eurasian watermilfoil collected during these months was characterized by lower levels of tissue N. During a 29-month period beginning January 1994, mean monthly water temperature for the Davis pond exceeded 20 C, only during July to September 1995. Tissue N was generally greater during summer for watermilfoil growing in the pond. These results imply that Eurasian watermilfoil biological control agents may have different developmental rates in these habitats, and thus different impacts on watermilfoil populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

determine the impact of water temperature on the efficacy of the contact herbicides diquat (6,7-dihydrodipyrido [1,2- α:2’,1’-c] pyrazinediium ion) and endothall (7-oxabicyclo [2.2.1] heptane-2,3-dicarboxylic acid) for control of the exotic nuisance species curlyleaf pondweed (Potamogeton crispus L.) across a range of water temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-energy laser-heating techniques are widely used in engineering applications such as, thinfilm deposition, surface treatment, metal forming and micro-structural pattern formation. In this paper,under the conditions of ignoring the thermo-mechanical coupling, a numerical simulation on the spatialand temporal temperature distribution in a sheet metal produced by the laser beam scanning in virtue of thefinite element method is presented. Both the three-dimensional transient temperature field and thetemperature evolution as a function of heat penetrating depth in the metal sheet are calculated. Thetemperature dependence of material properties was taken into account. It was shown that, after taking thetemperature dependence of the material absorbance effect into consideration, the temperature change ratealong the scanning direction and the temperature maximum were both increased.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The GlidArc discharge is one of the main generation methods of non-equilibrium plasma near atmospheric pressures. In general, Gliding Arc discharge is driven by gas flow [1] in axial direction or by magnetic field in circumferential direction. [2] In this paper, a GlidArc discharge driven by rotating-gas-flow in circumferential direction is presented. The principle of the plasma generator is analyzed. The distribution of the temperature in axial direction is measured by a digital thermometer for three different gases. The experimental set-up of the GlidArc plasma is shown in Fig.1. It consists of a center electrode, an outside electrode, a power supply and a gas supply. The shortest distance between the electrodes is 2-3 mm. When a power supply with 10000 volts is attached to the electrodes, the arc will be ignited at the shortest distance. The small plasma column is rotated by the rotating gas flow in circumferential direction and then the rotating arc is driven towards the exit of the setup by the gas flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In selecting an excess temperature at which to operate a power plant cooling system it has been customary to consider only thermal stresses and to use the ratio of the number of organisms killed to the number of organisms entrained. This frequently leads to the selection of a low excess temperature, AT, which, in turn, requires a large volume flow of cooling water. When mortalities due to physical and chemical stresses are included and the total number of entrained organisms killed is taken as the measure of the environmental damage, it becomes evident that the choice of a low excess temperature is seldom, if ever, best.