986 resultados para chloride corrosion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The local concentrations of chloride, Cl b, and bromide, Br b, in the interface of vesicles prepared with dioctadecyldimethylammonium chloride, DODAC, or bromide, DODAB, dipalmitoylphosphatidylcholine, DPPC, dimyristoylphosphatidylcholine, DMPC, and mixtures of DMPC, DPPC, and DODAC were determined by chemical trapping by analyzing product yields from spontaneous dediazoniation of vesicle-bound 2,6-dimethyl-4-hexadecylbenzenediazonium ion. The values of Cl b and Br b in DODAC and DODAB vesicles increase with vesicle size, in agreement with previous data showing that counterion dissociation decreases with vesicle size. Addition of tetramethylammonium chloride displaces bromide from the DODAB vesicular interface. The value for the selectivity constant for Br/Cl exchange at the DODAB vesicular interface obtained by chemical trapping was ∼2.0, well within values obtained for comparable amphiphiles. In vesicles of DPPC the values of Cl b were very sensitive to the nature of the cation and decreased in the order Ca 2+ > Mg 2+ > Li + > Na + > K + = Cs + = Rb + ≥ +. The effect of the cation becomes more important as temperature increases above the phase transition temperature, T m, of the lipid. The values of Cl b increased sigmoidally with the mol % of DODAC in vesicles prepared with DODAC/lipid mixtures. In sonicated vesicles prepared with DODAC and DMPC (or DPPC), the values of Cl b reach local concentrations measured for the pure amphiphile at 80 mol % DODAC. These results represent the first extensive study of local concentration of ions determined directly by chemical trapping in vesicles prepared with lipids, synthetic ampliiphiles, and their mixtures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 2024-T3 and 7050-T7 aluminium alloys electrochemical behavior has been studied in NaCl 5% neutral solutions and 0,1M concentration containing NO 3 - or NO 2 -. The current job supports corrosion research on aluminium alloys used in aeronautic industry. Open circuit potential, polarisation curves and electrochemical impedance spectroscopy techniques have been used. In chloride solutions, alloys corrosion takes place through a pitting mechanism. Added anions to aerated solutions do not possess inhibition effect. In deaerated solutions, nitrite has diminished anodic dissolution rate, probably by incorporating this anion in the oxide and/or hydroxide film.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Channel catfish ponds are treated with salt (sodium chloride) to increase chloride concentration and prevent nitrite toxicity in fish. A survey indicated that most farmers try to maintain chloride concentration of 50 to 100 mg/L in ponds by annual salt applications. Averages and standard deviations for selected water quality variables in salt-treated ponds were as follows: chloride, 87.2 ± 37.5 mg/L; total dissolved solids (TDS), 336 ± 96 mg/L; specific conductance, 512 ± 164 μmhos/cm. Maximum values were 189 mg/L for chloride, 481 mg/L for TDS, and 825 μmhos/cm for specific conductance. Good correlations between specific conductance values and both chloride and TDS concentrations suggest that specific conductance can be a rapid method for estimating concentrations of these two variables in surface water. The maximum limit for chloride concentration in Alabama streams allowed by the Alabama Department of Environmental Management is 230 mg/L. The usual recommended upper limit of TDS for protection of aquatic life in freshwater streams is 1,000 mg/L. Based on the observed relationship between TDS concentration and specific conductance in Alabama catfish ponds, 1,000 mg/L TDS corresponds to 1,733 μmhos/cm specific conductance. It is unlikely that effluents from salt-treated catfish ponds would violate the in-stream chloride standard of 230 mg/L or harm aquatic life in streams. Nevertheless, chloride concentrations in ponds should be measured before salt application as a safe guard against excessive salt application and chloride concentrations above the in-stream chloride standard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heavy metal oxide (HMO) glasses have received special attention due to their optical, electrical and magnetic properties. The problem with these glasses is their corrosive nature. In this work, three ceramic crucibles (Al 2O 3, SnO 2 and ZrO 2) were tested in the melting of the system 40 PbO-35 BiO 1.5-25 GaO 1.5 (cation-%). After glass melting, crucibles were transversally cut and analyzed by scanning electronic microscopy (SEM), coupled to microanalysis by energy dispersive spectroscopy (EDS). Results indicated that zirconia crucibles presented the highest corrosion, probably due to its smallest grain size. Tin oxide crucibles presented a low corrosion with small penetration of the glass into the crucible. This way, these crucibles are an interesting alternative to melt corrosive glasses in instead of gold or platinum crucibles. It is important to emphasize the lower cost of tin oxide crucibles, compared to gold or platinum ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to their low cost and high resistance to corrosion, ceramic crucibles can be used for the melting of PBG glasses (PbO-BiO 1.5GaO 1.5). These glasses present good window transmission from ultra-violet to infrared, making their use as optical fibres promising. However, their disadvantage is the high reactivity, leading to the corrosion of different crucibles, including gold and platinum ones. In this work, the corrosion of Al 2O 3, SnO 2 and ZrO 2 crucibles after melting at temperatures varying from 850 to 1000°C, was evaluated by Scanning Electronic Microscopy (SEM) in conjunction with microanalysis by EDS. The lead diffusion profile in the crucible material was obtained. Diffusion coefficients were calculated according to the Fick and Fisher theories. Results indicated that the different crucibles presented similar behaviour: in the region near the interface, diffusion occurs in the volumetric way and in regions away from the interface, diffusion occurs through grain boundary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A very new method application for digital image processing and analysis to classify shape and evaluate size and morphology parameters of pit corrosion is used in this paper. This method seems to be very effective to analysis surfaces with low or high degree of pitting formation. Pits formed on 2024 alloy surface by chloride and by chloride + molibdate anions have similar mean area, are found to be widther than deeper and exhibit predominantly conical or near-conical and irregular geometries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Individually caged male Cobb broilers (24), 44 d of age, were used to evaluate effects of heat stress (1 d of data collection) and dietary electrolyte balance (DEB; Na + K - Cl, mEq/kg from 1 d of age). During summer rearing, mortality was variable, but DEB 240 improved growth, feed conversion ratio, water intake, and waterrfeed ratio vs. DEB 0. The temperature sequence for heat stress was 24 to 32°C in 30 min, 32 to 36°C in 30 min, 36 to 37°C in 15 min, and 37 to 41°C in 45 min. Maximum temperature was held for 15, 60, 90, or 360 min for data collection (relative humidity averaged 42 ± 7%). Results from the same room before and after heat stress were analyzed by DEB (1-factor ANOVA) and before vs. after heat stress compared across DEB (2-sample t-test). Heat stress decreased blood Na, K, and pCO2, and lymphocytes but increased heterophils. Blood HCO3 rose, Cl declined, and hematocrit gave a concave pattern (lowest at DEB 120) as DEB increased. After heat stress, DEB O decreased blood Na and K, and DEB O and 120 levels decreased blood HCO3. After heat stress blood pCO2 and hemoglobin decreased with DEB 240, but it had highest pCO2, a key factor. The DEB 120 gave longest times to panting and prostration with DEB O and 240 results lower but similar statistically. In heat stress, DEB 360 was excessive, DEB 120 and 240 were favorable, and DEB 0 was intermediate based on hematology, panting, and prostration responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates corrosion behavior in graphite refractory hot metal impregnated with ZrO 2 and CeO 2 carrying solutions used in Blast Furnace hearth, consisting of 50% graphite and 50% anthracite. Corrosions tests were carried out by means of finger test method in an induction furnace, using bar-shaped 30×30×280 mm test specimens and hot metal from CSN#2 Blast Furnace runner. The temperature chosen for this test was 1520°C and sixty-minute isotherm. Upon test completion, test specimens were characterized by their dimensional variation, X-ray diffractometry and Scanning Electronic Microscopy (SEM).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The protection efficiency against water corrosion of fluorozirconate glass, ZBLAN, dip-coated by nanocrystalline tin oxide film containing the organic molecule Tiron® was investigated by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The chemical bonding structure of the surface region and morphology were studied before and after two water exposure periods of 5 and 30 min. The results of the analysis for the as-grown sample revealed a SnO1.6 phase containing carbon and sulfur, related to Tiron®, and traces of elements related to ZBLAN (Zr, F, Ba). This fact and the clear evidence of the presence of tin oxifluoride specie (SnOxF y) indicates a diffusion of the glass components into the porous coating. After water exposure, the increase of the oxygen concentration accompanied by a strong increase of Zr, F, Ba and Na content is interpreted as filling of the nanopores of the film by glass compounds. The formation of a compact protective layer is supported by the morphological changes observed by AFM. © 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ti-6Al-4V samples have been treated by PHI processing at different temperatures (400-800°C), treatment time (30-150 min) and plasma potential (100 and 420 V). Hardness measurements results showed an enhancement of the hardness for all implanted samples. XRD results detected the Ti 2N phase and the best corrosion resistance was found for the samples processed at higher temperature and lower PIII time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Urinary tract infection (UTI) is a very common condition in clinical practice, affecting an estimated 50% of all adult women during a lifetime. The most common causative agent is E. coli; UTI may also be caused by S. saprophyticus, Enterobacteria (Klebsiella sp and Serratia sp.), Enterococcus sp., and P aeruginosa. Recurrent UTIs occur at least twice per semester or three times a year. Prophylactic measures to prevent recurrent UTIs include changes in contraception methods, cranberry products, increased fluid intake, urination after intercourse, vaginal estrogen therapy for post-menopausal women, antibiotics, and urinary tract antiseptic agents. Objectives: To evaluate the use of a combination of methenamine and methyl-thioninium chloride in the prophylaxis of recurrent uncomplicated lower UTIs, with respect to: • Signs and symptoms of UTI • Etiologic agent(s) • Recurrence rates • Need for antibiotic therapy in case of recurrence • Incidence of adverse events associated with the treatment, including any reported alterations of laboratory tests Materials & methods: A descriptive, analytic, restrospective study was performed at Hospital Universitário Constantino Otaviano - UNIFESO. Medical charts from patients presenting recurrent uncomplicated lower UTI attended from 2001-present were analyzed, including the following information: Demographic data (age, gender, weight, ethnicity, living conditions): medical history/signs and symptoms of UTI; identification of treatment and dosing regimens; treatment duration; recurrence rates and need for antibiotic therapy in case of recurrence; other medications prescribed; and records of adverse events. Results: E. coli was identified as etiologic agent in 80% of the patients. Following antibiotic therapy, all patients received prophylactic treatment with the combination of methenamine and methylthioninium chloride. Treatment duration ranged from three to six months. Adverse events were observed in 13/60 patients (21.7%). At the end of the respective treatment periods, a statistically significant (p<0.0001) number of patients showed no UTI recurrence. Conclusion: Based on the results from the collected data, we conclude that an orally administered combination of methenamine and methylthioninium chloride is safe and effective in the prophylactic treatment of recurrent uncomplicated lower urinary tract infection. © Copyright Morelra Jr. Editora.