999 resultados para Traditional procedures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficiency of vigor tests in assessing the physiological potential of seeds depends on their standardization for different species. In this context, the research aimed to study specific methodologies to evaluate the vigor of spinach seeds (Tetragonia tetragonoides). For this purpose, five lots of spinach seed cv. New Zealand were submitted to germination, first count of germination, seedling emergence in the field, accelerated aging (with and without use of saturated solution of NaCl at 41and 45 ºC for 24,48 and 72 hours), controlled deterioration (18,21 and 24% seed water content adjustments for 24 hours at 45 ºC) and electrical conductivity tests with variations inwater volume (25, 50 and 75 mL), seed quantity (25 and 50) and soaking period (1, 2, 4, 8,12, 16 and 24 hours) at 25 ºC. The first count test allowed obtaining preliminary information about seed vigor, and other tests in general showed similarity with seedling emergence in the field. Thus, it was concluded that traditional accelerated aging test 24 h /41 ºC and accelerated aging test with saturated salt solution for 24 h at 41 ºC and 45 ºC, and controlled deterioration test with 21% seed water content / 24 h / 45 ºC were all efficient for evaluating the physiological potential of spinach seeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated alternatives for producing erosion susceptibility maps, considering different weight combinations for an environment's attributes, according to four different points of views. The attributes considered were landform, steepness, soils, rocks and land occupation. Considered alternatives were: (1) equal weights, more traditional approach, (2) different weights, according to a previous study in the area, (3) different weights, based on other works in the literature, and (4) different weights based on the analytical hierarchical process. The area studied included the Prosa Basin located in Campo Grande-Mato Grosso do Sul State, Brazil. The results showed that the assessed alternatives can be used together or in different stages of studies aiming at urban planning and decision-making on the interventions to be applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of heat treatment (HT) procedures of a pre-hydrolyzed silane on bond strength of resin cement to a feldspathic ceramic.Materials and Methods: Ceramic and composite blocks (N = 30) were divided into six groups (n = 5) and subjected to the following conditioning procedures: G1: 9.6% hydrofluoric acid (HF) for 20 s + silane (RelyX Ceramic Primer, 3M ESPE) + resin cement (Panavia F2.0, Kuraray) (control); G2: HF (20 s) + silane + heat treatment in furnace (HTF) (100 degrees C, 2 min) + resin cement; G3: silane + HTF + resin cement; G4-HF (20 s) + silane + heat treatment with hot air (HTA) (50 +/- 5 degrees C for 1 min) + resin cement; G5: silane + HTA + resin cement; G6: silane + resin cement. The microtensile bond strength (MTBS) test was performed using a universal testing machine (1 mm/min). After debonding, the substrate and adherent surfaces were analyzed using a stereomicroscope and SEM to categorize the failure types. The data were statistically evaluated using one-way ANOVA and Tukey's test (5%).Results: The control group (G1) showed no pre-test failures and presented significantly higher mean MTBS (16.01 +/- 1.12 MPa) than did other groups (2.63 +/- 1.05 to 12.55 +/- 1.52 MPa) (p = 0.0001). In the groups where HF was not used, HTF (G3: 12.55 +/- 1.52 MPa) showed significantly higher MTBS than did HTA (G5: 2.63 +/- 1.05 MPa) (p < 0.05). All failure types were mixed, ie, adhesive between the resin cement and ceramic accompanied by cohesive failure in the cement.Conclusion: Heat treatment procedures for the pre-hydrolyzed silane either in a furnace or with the application of hot air cannot replace the use of HF gel for the adhesion of resin cement to feldspathic ceramic. Yet when mean bond strengths and incidence of pre-test failures are considered, furnace heat treatment delivered the second best results after the control group, being considerably better than hot air application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: the relationship between professional and patient oriented by humanization standards is a current issue in health research, since this relationship influences the processes of physical recovery, pain reduction and quality of life of individuals. However, this is not observed in most graduate programs in health, which emphasize knowledge and methods in the traditional Cartesian thinking. Objective: to evaluate the importance of contents and practices with a focus on issues of embodiment and alterity, from the perspective of the humanization of health in Physiotherapy courses. Method: we used a qualitative method and data were collected through semi-structured interviews conducted by five randomly selected physiotherapists, aged between 23 and 36 years, with professional experience between two and thirteen years. The questions were on: physical therapy, physical therapist and patient relationship, work pace, involvement in trade associations, field and insert content and practices of the humanization of health in undergraduate courses. Result: the Physiotherapy graduate courses do not prepare the professional to take a close bond with patients. The application of techniques and protocols are focused on knowledge and do not apply to skills related to living together. Conclusion: the curriculum of graduating courses in health should be revised to expand the capacity of the students to become a professional who take care of patients and act as mediator between techniques and protocols, from the perspective of humanization of health, which requires contents and procedures based on embodiment and alterity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work assessed the performance of membranes made of natural latex extracted from Hevea brasiliensis prepared with three different methods: polymerized immediately after collection without the use of ammonia (L1); polymerized after preservation in ammonia solution (L2); and polymerized after storage in ammonia, followed by Soxhlet technique for the extraction of substances (L3). Polytetrafluoroethylene (PTFE) membrane was used as control. Two 10-mm diameter bone defects were surgically made in the calvaria of thirty adult male New Zealand rabbits. Defects (total n = 60) were treated with guided bone regeneration (GBR) using L1, L2, L3 or PTFE membranes (n = 15 for each membrane). Ten animals were euthanized after 7, 20 and 60 days postoperatively so that five samples (n = 5) of each treatment were collected at each time, and bone regeneration was assessed microscopically. The microscopic analysis revealed defects filled with blood clot and new bone formation at the margins of the defect in all 7-day samples, while 20-day defects were mainly filled with fibrous connective tissue. After 60 days defects covered with L1 membranes showed a significantly larger bone formation area in comparison to the other groups (P < 0.05, ANOVA, Tukey). Additionally, bone tissue hypersensitization for L1 and PTFE membranes was also investigated in six additional rabbits. The animals were subjected to the same surgical procedure for the confection of one 10-mm diameter bone defect that was treated with L1 (n = 3) or PTFE (n = 3). Fifty-three days later, a second surgery was performed to make a second defect, which was treated with the same type of membrane used in the first surgery. Seven days later, the animals were euthanized and samples analyzed. No differences among L1 and PTFE samples collected from sensitized and non-sensitized animals were found (P > 0.05, Kruskal-Wallis). Therefore, the results demonstrated that latex membranes presented performance comparable to PTFE membranes, and that L1 membranes induced higher bone formation. L1 and PTFE membranes produced no hypersensitization in the bone tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To determine the effects of different aging methods on the degradation and flexural strength of yttria-stabilized tetragonal zirconia (Y-TZP)Methods. Sixty disc-shaped specimens (0, 12 mm; thickness, 1.6 mm) of zirconia (Vita InCeram 2000 YZ Cubes, VITA Zahnfabrik) were prepared (ISO 6872) and randomly divided into five groups, according to the aging procedures (n=10): (C) control; (M) mechanical cycling (15,000,000 cycles/3.8 Hz/200N); (T) thermal cycling (6,000 cycles/5-55 degrees C/30 s); (TM) thermomechanical cycling (1,200,000 cycles/3.8 Hz/200N with temperature range from 5 C to 55 C for 60s each); (AUT) 12h in autoclave at 134 degrees C/2 bars; and (STO) storage in distilled water (37 degrees C/400 days). After the aging procedures, the monoclinic phase percentages were evaluated by X-ray diffraction (XRD), and topographic surface analysis was performed by 3D profilometry. The specimens were then subjected to biaxial flexure testing (1 mm/min, load 100 kgf, in water). The biaxial flexural strength data (MPa) were analyzed by 1-way ANOVA and Tukey's test (alpha = 0.05). The data for monoclinic phase percentage and profilometry (Ra) were analyzed by Kruskal-Wallis and Dunn's tests.Results. ANOVA revealed that flexural strength was affected by the aging procedures (p = 0.002). The M (781.6 MPa) and TM (771.3 MPa) groups presented lower values of flexural strength than did C (955 MPa), AUT (955.8 MPa), T (960.8 MPa) and STO (910.4 MPa). The monoclinic phase percentage was significantly higher only for STO (12.22%) and AUT (29.97%) when compared with that of the control group (Kruskal-Wallis test, p = 0.004). In addition, the surface roughnesses were similar among the groups (p = 0.165).Signcance. Water storage for 400 days and autoclave aging procedures induced higher phase transformation from tetragonal to monoclinic; however, they did not affect the flexural strength of Y-TZP ceramic, which decreased only after mechanical and thermomechanical cycling. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)