993 resultados para Technical loss


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents holistic design of a novel four-way differential power-combining transformer for use in millimeter-wave power-amplifier (PA). The combiner with an inner radius of 25 µm exhibits a record low insertion loss of 1.25 dB at 83.5 GHz. It is designed to simultaneously act as a balanced-to-unbalanced converter, removing the need for additional BALUNs typically required in differential circuits. A complete circuit comprised of a power splitter, two-stage differential cascode PA array, a power combiner as well as input and output matching elements was designed and realized in SiGe technology with f/f 170/250 GHz. Measured small-signal gain of at least 16.8 dB was obtained from 76.4 to 85.3 GHz with a peak 19.5 dB at 83 GHz. The prototype delivered 12.5 dBm output referred 1 dB compression point and 14 dBm saturated output power when operated from a 3.2 V dc supply voltage at 78 GHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an ultrafast wideband low-loss single-pole double-throw (SPDT) differential switch in 0.35 µ m SiGe bipolar technology. The proposed topology adopting current-steering technique results in a total measured switching time of 75 ps , which suggests a maximum switching rate of 13 Gb/s, the fastest ever reported at V-band. In addition, the switch exhibits an insertion loss lower than 1.25 dB and an isolation higher than 18 dB from 42 GHz to 70 GHz. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design and characterization of ultrafast wideband low-loss single-pole single-throw (SPST) and single-pole double-throw (SPDT) differential switches. The SPDT switch exhibits insertion loss of lower than 1.25 dB from 42 to 70 GHz and isolation of better than 20 dB from 40 to 65 GHz. Similar low-loss and broadband characteristics are also observed from the measured SPST switch. The proposed switch topologies adopting current-steering technique and implemented in 0.35 µm SiGe bipolar technology result in a switching time of only 75 ps. This suggests a maximum switching speed of 13 Gbps, the fastest ever reported at V-band.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of photon frequency redistribution by line branching on mass-loss rates for hot luminous stars is investigated. Monte Carlo simulations are carried out for a range of OB star models which show that previous mass-loss calculations which neglect non-resonance line scattering overestimate mass-loss rates for luminous O stars by ~20 per cent. For luminous B stars the effect is somewhat larger, typically ~50 per cent. A Wolf-Rayet star model is used to investigate line branching in the strong wind limit. In this case the effect of line branching is much greater, giving mass-loss rates that are smaller by a factor ~3 from computations which neglect branching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe fundus autofluorescence (AF) patterns and their change over time in patients with age-related macular degeneration (AMD) and high risk of visual loss participating in the drusen laser study (DLS). DESIGN: Randomized clinical trial. METHODS: The study population consisted of 29 patients (35 eyes) participating in the DLS, which is a prospective, randomized, controlled clinical trial of prophylactic laser therapy in patients with AMD and high risk of neovascular complications. The intervention consisted of 16 eyes having prophylactic laser and 19 receiving no treatment. The main outcome measures were changes in the distribution of drusen and AF. Patients were reviewed for a median follow-up or 24 months (range 12-36 months). RESULTS: At baseline, four patterns of fundus AF were recognized: focal increased AF (n = 18), reticular AF (n = 3), combined focal and reticular AF (n = 2), and homogeneous AF (n = 12). At last follow-up, fundus AF remained unchanged in 15 untreated (78%) and in seven treated (43%) eyes. In only one untreated eye, focal areas of increased AF returned to background levels and were no longer detectable at last follow-up, compared with six treated eyes. This difference was statistically significant (P = .03). Only large foveal soft drusen (drusenoid pigment epithelium detachments) consistently corresponded with focal changes in AF, whereas no obvious correspondence was found between small soft drusen located elsewhere and changes in AF. CONCLUSION: The lack of obvious correspondence between the distribution of drusen and of AF found in this study appears to indicate that drusen and AF represent independent measures of aging in the posterior pole. © 2002 Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the temporal course of corneal sensitivity loss & the role of aldose reductase inhibitors (ARI) in an animal model of diabetic ocular complications. Methods: Weanling male S-D rats were randomly grouped to received ad libitum water & diet consisting of Purina (#5001) w/ either: 50% starch (CON,n=15) or 50% D-galactose (GAL,n=30). Half the galactosemic rats (ARI,n=15) received topical 0.25% CT-112 (3x daily, 20µl, Senju Pharmaceutical Co., Japan). Control & remaining half of the galactosemic animals received equivalent doses of saline eyedrops. Rats were restrained w/o medication during sensitivity measurements conducted w/ a Cochet-Bonnet Aesthesiometer mounted on a micromanipulator. The end of the filament (0.012mm dia.), which applied a mean pressure of 0.96 g/mm perpendicular to the corneal surface at center, was in the plane of focus of a slit-lamp biomicroscope. Measurements were conducted by two investigators which were masked to the treatment group. The average blink-responses from 10 consecutive stimuli to each cornea were expressed as a percent. Results: Mean (±SD) baseline corneal sensitivity in all groups were similar (CON 73%±11, GAL 71%±15, ARI 74%±16). Corneal sensitivity in the galactosemic rat was decreased (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been shown that mitomycin-C increases the success rate of trabeculectomy; however, a rise in the incidence of postoperative complications has also been reported. Consequently, the use of antimetabolite is usually reserved for patients who are at high risk of surgical failure or for patients with advanced glaucoma in whom low intraocular pressure is desired. This report describes a patient who suffered severe visual loss which was a direct result of hypotonous maculopathy after trabeculectomy with mitomycin-C and various other complications from the subsequent interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The traditional training of surgeons focused exclusively on developing knowledge, clinical expertise, and technical (surgical) skills. However, analyses of the reasons for adverse events in surgery have revealed that many underlying causes originate from behavioural or non-technical aspects of performance (eg, poor communication among members of the surgical team) rather than from a lack of surgical (ie, technical) skills. Therefore, technical skills appear to be necessary but not sufficient to ensure patient safety. Paying attention to non-technical skills, such as team working, leadership, situation awareness, decision making, and communication, will increase the likelihood of maintaining high levels of error-free performance. Identification and training of non-technical skills has been developed for high-risk careers, such as civil aviation and nuclear power. Only recently, training in non-technical skills has been adopted by the surgical world and anaesthetists. Non-technical skills need to be tailored to the environment where they are used, and eye surgery has some substantial differences compared with other surgical areas, for example, high volume of surgery, use of local anaesthetics, and very sophisticated equipment. This review highlights the need for identification of the non-technical skills relevant to eye surgeons and promotion of their use in the training of eye surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recent National Institute of Clinical Excellence guidance suggests primary surgery should be offered to patients presenting with glaucoma with severe visual field loss. We undertook a survey of UK consultant ophthalmologists to determine if this represents current practice and explore attitudes towards managing patients with advanced glaucoma at presentation.

DESIGN: Questionnaire evaluation study.

PARTICIPANTS: All consultant ophthalmologists currently practicing in the UK.

METHODS: A single-page questionnaire was posted to all consultants (n = 910) currently practicing in the UK along with a pre-paid return envelope. A second questionnaire was sent to non-responders (n = 459).

MAIN OUTCOME MEASURES: Questionnaire responses.

RESULTS: 626 responses were received representing 68.8% of the population surveyed. 152 (24%) volunteered a specialist interest in glaucoma. Consensus opinion for both glaucoma specialists (64.9%) and non-glaucoma specialists (62.4%) was to start with primary medical therapy, most commonly citing surgical risk as the primary reason (23% and 22%, respectively) for this approach. Most felt the highest intraocular pressure measurement during follow up (measured in clinic) was the most important variable for prevention of further visual loss (60% of glaucoma specialists and 55% of non-glaucoma specialists). Eighty-three per cent of all responders suggested they would change their practice if evidence supporting primary surgery as a safe and more effective approach existed.

CONCLUSIONS: Recent National Institute of Clinical Excellence guidance does not reflect the current management approach of UK ophthalmologists. The primary concern was related to potential complications of surgery although most practitioners would be willing to change their practice if evidence existed supporting primary surgery in patients presenting with advanced glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Small off-road engines (SORE) have been recognised as a major source of air pollution. It is estimated that non handheld SORE annually produce over 1 million tonnes of HC+NOx and over 50 million tonnes of CO2. The fuel system design and its operating AFR are of key importance with regard to engine operation and engine out emissions. The conventional low-cost float carburettors used in these engines are relatively ineffective at atomising and preparing the fuel for combustion requiring a rich setting for acceptable functional performance. EPA and CARB have confirmed that Phase 3 limits are achievable for a “durable” engine fitted with a conventional well calibrated and manufactured “stock rich setting” float carburettor together with catalytic oxidation after-treatment and passive secondary air injection. The EPA and CARB strategy for meeting Phase 3 only considers the use of conventional float carburettors that operate at rich AFR’s over their entire engine operating range as no other cost effective alternative fuel system is yet available on the market. A cost effective alternative to the conventional carburettor that enabled leaner or optimised AFR operation with load and improved combustion performance would open the door to alternative strategies to meeting the phase 3 limits. This paper presents a completely new form of mechanical carburettor that gives AFR control with load, improved mixture preparation for improved combustion performance and has a lower production cost than conventional carburettors. The conventional and new fuel system designs and operation are discussed in detail and their technical merits demonstrated in the form of engine test data. The performance of different after-treatment systems is also simulated for different AFR profiles with load for a conventional or unmodified SORE engine. With optimised leaner operation and improved combustion characteristics, this new carburettor technology can provide significant engine out CO and HC+NOx reductions on the J1088 test cycle without loss of functional performance. Depending on the chosen emissions control strategy, minimum engine out emissions or optimum engine AFR for oxidation or three-way after-treatment or another, this new carburettor technology can be easily calibrated to provide the desired engine operating AFR profile on the J1088 cycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the design, implementation, and characterization of a new type of passive power splitting and combining structure for use in a differential four-way power-combining amplifier operating at E-band. In order to achieve lowest insertion loss, input and output coils inductances are resonated with shunt capacitances. Simple C-L-C and L-C networks are proposed in order to compensate inductive loading due to routing line that would otherwise introduce mismatch and increase loss. Across 78-86 GHz band, measured insertion loss is about 7 dB. Measured return losses are >10 dB from 73 GHz to 94 GHz at the input port and >9 dB from 60 GHz to 94 GHz at the output port. When integrated with driver and power amplifier cells, the simulated complete circuit exhibits 18.2 dB gain and 20.3 dBm saturated output power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims/hypothesis: In previous studies we have shown that extravasated, modified LDL is associated with pericyte loss, an early feature of diabetic retinopathy (DR). Here we sought to determine detailed mechanisms of this LDLinduced pericyte loss.

Methods: Human retinal capillary pericytes (HRCP) were exposed to ‘highly-oxidised glycated’ LDL (HOG-LDL) (a model of extravasated and modified LDL) and to 4-hydroxynonenal or 7-ketocholesterol (components of oxidised LDL), or to native LDL for 1 to 24 h with or without 1 h of pretreatment with inhibitors of the following: (1) the scavenger receptor (polyinosinic acid); (2) oxidative stress (N-acetyl cysteine); (3) endoplasmic reticulum (ER) stress (4-phenyl butyric acid); and (4) mitochondrial dysfunction (cyclosporin A). Oxidative stress, ER stress, mitochondrial dysfunction, apoptosis and autophagy were assessed using techniques including western blotting, immunofluorescence, RT-PCR, flow cytometry and TUNEL assay. To assess the relevance of the results in vivo, immunohistochemistry was used to detect the ER stress chaperon, 78 kDa glucose-regulated protein, and the ER sensor, activating transcription factor 6, in retinas from a mouse model of DR that mimics exposure of the retina to elevated glucose and elevated LDL levels, and in retinas from human participants with and without diabetes and DR.

Results: Compared with native LDL, HOG-LDL activated oxidative and ER stress in HRCP, resulting in mitochondrial dysfunction, apoptosis and autophagy. In a mouse model of diabetes and hyperlipidaemia (vs mouse models of either condition alone), retinal ER stress was enhanced. ER stress was also enhanced in diabetic human retina and correlated with the severity of DR.

Conclusions/interpretation: Cell culture, animal, and human data suggest that oxidative stress and ER stress are induced by modified LDL, and are implicated in pericyte loss in DR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications(EDIC) studies have established multiyear mean hemoglobin A1c (HbA1c) as predictive of microvascular complications in persons with type 1 diabetes. However, multiyear mean HbA1c is not always available in the clinical setting. Skin advanced glycation end products (AGEs) are thought to partially reflect effects of hyperglycemia over time, and measurement of skin AGEs might be a surrogate for multiyear mean HbA1c. As certain AGEs fluoresce and skin fluorescence has been demonstrated to correlate with the concentration of skin AGEs, noninvasive measurement by skin intrinsic fluorescence(SIF) facilitates the exploration of the association of mean HbA1c and other clinical/technical factors with SIF using the detailed phenotypic database available in DCCT/EDIC.