984 resultados para TISSUE DOPPLER IMAGING
Resumo:
In this paper we present results on the optimization of device architectures for colour and imaging applications, using a device with a TCO/pinpi'n/TCO configuration. The effect of the applied voltage on the color selectivity is discussed. Results show that the spectral response curves demonstrate rather good separation between the red, green and blue basic colors. Combining the information obtained under positive and negative applied bias a colour image is acquired without colour filters or pixel architecture. A low level image processing algorithm is used for the colour image reconstruction.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Ressonância Magnética
Resumo:
Introdução – A técnica de Difusão por Ressonância Magnética (RM), ao avaliar o movimento das moléculas de água nos tecidos, permite inferir sobre a arquitetura dos mesmos, em particular relativamente à celularidade, volume celular e permeabilidade das membranas. O Coeficiente de Difusão Aparente (ADC) é um parâmetro quantificável da imagem ponderada em difusão (DWI). A sua análise poderá fornecer informação clínica adicional sobre estas lesões, sobretudo em relação à sua caracterização histológica. Objetivos – Caracterizar e diferenciar tipos e alguns subtipos de lesões mamárias através da análise do ADC. Metodologia – 20 Mulheres com 23 lesões mamárias foram submetidas a RM mamária: 3 lesões benignas (3 Fibroadenomas-FA) e 20 malignas (16 Carcinomas Ductais Invasivos-CDI, 2 Carcinomas Ductais In Situ-CDIS e 2 Carcinomas Invasivos Lobulares-CLI). Num equipamento 1.5T aplicou-se uma sequência de Difusão (b=0,50,250,500,750,1000 s/mm2). Obteve-se o ADC através do ajuste exponencial da intensidade de sinal das lesões em função do valor de b, fazendo-se corresponder os valores de ADC à respetiva caracterização histológica e posterior comparação com a literatura. Resultados e Discussão – As lesões malignas apresentaram ADCs significativamente (p=0,014) inferiores [(0,94±0,22)x10-3 mm2/s] aos das benignas [(1,43±0,25)x10-3 mm2/s]. A justificação pode residir no aumento da celularidade e consequente restrição da Difusão que se observa nas lesões malignas. Os CDI apresentaram ADCs baixos [(0,88±0,17)x10-3 mm2/s], enquanto que os CDIS apresentaram ADCs mais elevados [(1,33±0,29)x10-3 mm2/s]. Estes resultados estão de acordo com o facto dos CDIS estarem limitados aos ductos mamários, mantendo-se menos alterada a estrutura do tecido adjacente e resultando numa menor restrição à difusão que nos CDI. Verificaram-se diferenças significativas entre FA e CDI (p=0,010) e entre CDI e CDIS (p=0,049). Conclusões – O ADC possibilita a diferenciação entre lesões mamárias benignas e malignas, bem como entre alguns tipos histológicos. O desenvolvimento deste conceito pode representar um avanço no papel da RM na avaliação destas neoplasias. ABSTRACT - Introduction – The Magnetic Resonance (MR) diffusion technique measures the movement of water molecules in tissues. Therefore, it provides useful information about tissue architecture, specially regarding tissue cellularity, cell volume and membrane permeability. The quantification of diffusion weighted imaging (DWI) data is done by measuring the so-called. Apparent Diffusion Coefficient (ADC). This parameter provides additional clinical information about breast lesions, and potentially allows for in-vivo histological characterization. Purpose – To characterize and differentiate breast lesions through ADC analysis. Methodology – The study comprised 20 women, with 23 breast lesions: 3 benign lesions - 3 Fibroadenomas (FA); and 20 malignant - 16 Invasive Ductal Carcinomas (CDI), 2 Ductal Carcinomas In Situ (CDIS), 2 Invasive Lobular Carcinoma (CLI). On a 1.5T equipment a diffusion-weighted sequence with 6 b-values (b=0,50,250,500,750,1000 s/mm2) was used to examine the patients. ADC was obtained by fitting an exponential to data of lesion signal intensity vs. b values. A correspondence of ADC values to histological lesion characterization was done and finally, the results were comparison with the literature. Results and Discussion – Malignant lesions showed inferior ADCs significantly (p=0.014) lower ((0.94±0.22)x10-3 mm2/s) than the benign lesions ((1.43±0.25)x10-3 mm2/s). This may be associated to increasead cellularity in malignant lesions, which result in higher tissue restriction to diffusion. CDI showed low ADC values ((0.88±0.17)x10-3 mm2/s), while the CDIS showed higher ADCs ((1.33±0.29)x10-3 mm2/s). These results agree with the fact that CDIS are limited to mammary ducts, maintaining a less altered neighboring tissue structure, which results in a lower restriction to diffusion than observed in CDI. Significant differences between FA and CDI (p=0.010) and between CDI and CDIS (p=0.049) were observed. Conclusion – The ADC parameter is able to differentiate between malignant and benign breast lesions, as well as between some histological types.
Resumo:
Advances in digital technology led to the development of digital x-ray detectors that are currently in wide use for projection radiography, including Computed Radiography (CR) and Digital Radiography (DR). Digital Imaging Systems for Plain Radiography addresses the current technological methods available to medical imaging professionals to ensure the optimization of the radiological process concerning image quality and reduction of patient exposure. Based on extensive research by the authors and reference to the current literature, the book addresses how exposure parameters influence the diagnostic quality in digital systems, what the current acceptable radiation doses are for useful diagnostic images, and at what level the dose could be reduced to maintain an accurate diagnosis. The book is a valuable resource for both students learning the field and for imaging professionals to apply to their own practice while performing radiological examinations with digital systems.
Resumo:
Claustrophobia causes a huge discomfort to those who need to perform Magnetic Resonance examinations mainly due to the physical design of most equipment. This study aimed to maximize the success rate of Magnetic Resonance Imaging (MRI) clinical studies in claustrophobic patients by the identification of facilitative strategies.
Resumo:
Mestrado em Medicina Nuclear.
Resumo:
Many solid tumors have a poor response to systemic chemotherapy, local radiotherapy or surgical recession. They are responsible for premature morbidity and decreased patient survival. The radiofrequency ablation is an emerging technique, and is now becoming more widespread throughout the world because it is minimally invasive, image guided, which offers the possibility of an effective and less costly approach. The procedure can be performed percutaneously, guided by several imaging modalities as Ultrasound, Computed Tomography and Magnetic Resonance. This article pretends to demonstrate the state-of-the-art of this technique focusing in the technical aspects and application of radiofrequency ablation.
Resumo:
Susceptibility-weighted imaging (SWI) is a relatively new contrast in MR imaging. Previous studies have found an effect of caffeine in the contrast generated by SWI images. The present study investigates the effect of caffeine on contrast-to-noise ratio (CNR) in SWI.
Resumo:
We present new Rayleigh-wave dispersion maps of the western Iberian Peninsula for periods between 8 and 30 s, obtained from correlations of seismic ambient noise, following the recent increase in seismic broadband network density in Portugal and Spain. Group velocities have been computed for each station pair using the empirical Green's functions generated by cross-correlating one-day-length seismic ambient-noise records. The resulting high-path density allows us to obtain lateral variations of the group velocities as a function of period in cells of 0.5 degrees x 0.5 degrees with an unprecedented resolution. As a result we were able to address some of the unknowns regarding the lithospheric structure beneath SW Iberia. The dispersion maps allow the imaging of the major structural units, namely the Iberian Massif, and the Lusitanian and Algarve Meso-Cenozoic basins. The Cadiz Gulf/Gibraltar Strait area corresponds to a strong low-velocity anomaly, which can be followed to the largest period inverted, although slightly shifted to the east at longer periods. Within the Iberian Massif, second-order perturbations in the group velocities are consistent with the transitions between tectonic units composing the massif. (C) 2013 Elsevier B.V. All rights reserved.