1000 resultados para Sistemas de recuperação da informação - Meio ambiente
Resumo:
Effluents from pesticide industries have great difficulty to decontaminate the environment and, moreover, are characterized by high organic charge and toxicity. The research group Center for Chemical Systems Engineering (CESQ) at the Department of Chemical Engineering of Polytechnical School of University of São Paulo and Department of Chemical Engineering, Federal University of Rio Grande do Norte have been applying the Advanced Oxidation Processes (AOP's) for the degradation of various types of pollutants. These processes are based on the generation of hydroxyl radicals, highly reactive substances. Thus, this dissertation aims to explore this process, since it has been proven to be quite effective in removing organic charge. Therefore, it was decided by photo-Fenton process applied to the degradation of the fungicide Thiophanate methyl in aqueous system using annular reactor (with lamp Philips HPLN 125W) and solar. The samples were collected during the experiment and analyzed for dissolved organic carbon (TOC) using a Shimadzu TOC (Shimadzu 5050A e VCP). The Doehlert experimental design has been used to evaluate the influence of ultraviolet radiation, the concentrations of methyl thiophanate (C12H14N4O4S2), hydrogen peroxide (H2O2) and iron ions (Fe2+), among these parameters, was considered the best experimental conditions, [Fe2+] = 0.6 mmol/L and [H2O2] = 0.038 mol/L in EXP 5 experiment and in SOL 5 experiment, obtaining a percentage of TOC removal of 60% in the annular reactor and 75% in the solar reactor
Resumo:
The generation of effluent from the finishing process in textile industry is a serious environmental problem and turned into an object of study in several scientific papers. Contamination with dyes and the presences of substances that are toxic to the environment characterize this difficult treatment effluent. Several processes have already been evaluated to remove and even degrade such pollutants are examples: coagulation-flocculation, biological treatment and advanced oxidative processes, but not yet sufficient to enable the recovery of dye or at least of the recovery agent. An alternative to this problem is the cloud point extraction that involves the application of nonionic surfactants at temperatures above the cloud point, making the water a weak solvent to the surfactant, providing the agglomeration of those molecules around the dyes molecules by affinity with the organic phase. After that, the formation of two phases occurred: the diluted one, poor in dye and surfactant, and the other one, coacervate, with higher concentrations of dye and surfactants than the other one. The later use of the coacervate as a dye and surfactant recycle shows the technical and economic viability of this process. In this paper, the cloud point extraction is used to remove the dye Reactive Blue from the water, using nonionic surfactant nonyl phenol with 9,5 etoxilations. The aim is to solubilize the dye molecules in surfactant, varying the concentration and temperature to study its effects. Evaluating the dye concentration in dilute phase after extraction, it is possible to analyze thermodynamic variables, build Langmuir isotherms, determine the behavior of the coacervate volume for a surfactant concentration and temperature, the distribution coefficient and the dye removal efficiency. The concentration of surfactant proved itself to be crucial to the success of the treatment. The results of removal efficiency reached values of 91,38%, 90,69%, 89,58%, 87,22% and 84,18% to temperatures of 65,0, 67,5, 70,0, 72,5 and 75,0°C, respectively, showing that the cloud point extraction is an efficient alternative for the treatment of wastewater containing Reactive Blue
Resumo:
Environmental Laws and Regulations to dump wastewater are increasingly relevant and, together with pressure from environmentalists, provide awareness of academics in search of solutions. In Brazil, federal law, through Resolution No. 357 of 17/03/05 of the National Environmental Council - CONAMA, in Article 24 deals with the disposal of these effluents. Water pollution with heavy metals is concern because of the difficulty of the treatment and removal from the environment. Copper, for example, is a metallic element and in the form of salt is very soluble in water which dificults its removal. In this context, this study aims to evaluate the extraction of copper with acrylamide polymers through the process of assisted flocculation followed by filtration. Therefore, we used acrylamide polymers, produced by SNF Floerger, with varying degrees of ionicity which is the parameter examined on the extraction of copper. We used the FA polymers FA 920 SH, AH 912 SH, AN 905 SH, AN 910 SH, AN 923 SH, AN 945 SH, AN 956 SH and AN 977 SH, which have anionicities different from each other and growing in that order. The parameters temperature, pH, concentration of the copper solution and stirring speed are fixed. The polymer solution was added to a solution of 200 ppm copper, varying the concentration of polymer. After stirring, an assisted flocculation occurred followed by filtration of the effluent. The filtrate was analyzed by atomic absorption spectrophotometer and the percentage removal of copper ranged from 63 % to 97 %, noting that polymers with higher ionic charge were responsible for the highest percentage of copper extraction. The results of this study showed that these polymers can be applied in the treatment of wastewaters containing metals such as copper
Resumo:
The need for new sources of energy and the concern about the environment have pushed the search for renewable energy sources such as ethanol. The use of lignocellulosic biomass as substrate appears as an important alternative because of the abundance of this raw material and for it does not compete with food production. However, the process still meets difficulties of implementation, including the cost for production of enzymes that degrade cellulose to fermentable sugars. The aim of this study was to evaluate the behavior of the species of cactus pear Opuntia ficus indica and Nopalea cochenillifera, commonly found in northeastern Brazil, as raw materials for the production of: 1) cellulosic ethanol by simultaneous saccharification and fermentation (SSF) process, using two different strains of Saccharomyces cerevisiae (PE-2 and LNF CA-11), and 2) cellulolytic enzymes by semi-solid state fermentation (SSSF) using the filamentous fungus Penicillium chrysogenum. Before alcoholic fermentation process, the material was conditioned and pretreated by three different strategies: alkaline hydrogen peroxide, alkaline using NaOH and acid using H2SO4 followed by alkaline delignification with NaOH. Analysis of composition, crystallinity and enzymatic digestibility were carried out with the material before and after pretreatment. In addition, scanning electron microscopy images were used to compare qualitatively the material and observe the effects of pretreatments. An experimental design 2² with triplicate at the central point was used to evaluate the influence of temperature (30, 40 and 45 °C) and the initial charge of substrate (3, 4 and 5% cellulose) in the SSF process using the material obtained through the best condition and testing both strains of S. cerevisiae, one of them flocculent (LNF CA-11). For cellulase production, the filamentous fungus P. chrysogenum was tested with N. cochenillifera in the raw condition (without pretreatment) and pretrated hydrothermically, varying the pH of the fermentative medium (3, 5 and 7). The characterization of cactus pear resulted in 31.55% cellulose, 17.12% hemicellulose and 10.25% lignin for N. cochenillifera and 34.86% cellulose, 19.97% hemicellulose and 15.72% lignin for O. ficus indica. It has also been determined, to N. cochenillifera and O. ficus indica, the content of pectin (5.44% and 5.55% of calcium pectate, respectively), extractives (26.90% and 9.69%, respectively) and ashes (5.40% and 5.95%). Pretreatment using alkaline hydrogen peroxide resulted in the best cellulose recovery results (86.16% for N. cochenillifera and 93.59% for O. ficus indica) and delignification (48.79% and 23.84% for N. cochenillifera and O. ficus indica, respectively). This pretreatment was also the only one which did not increase the crystallinity index of the samples, in the case of O. ficus indica. However, when analyzing the enzymatic digestibility of cellulose, alkali pretreatment was the one which showed the best yields and therefore it was chosen for the tests in SSF. The experiments showed higher yield of conversion of cellulose to ethanol by PE-2 strain using the pretreated N. cochenillifera (93.81%) at 40 °C using 4% initial charge of cellulose. N. cochenillifera gave better yields than O. ficus indica and PE-2 strain showed better performance than CA-11. N. cochenillifera proved to be a substrate that can be used in the SSSF for enzymes production, reaching values of 1.00 U/g of CMCase and 0.85 FPU/g. The pretreatment was not effective to increase the enzymatic activity values
Resumo:
Increasing concern with the environment, in addition to strict laws, has induced the industries to find altenatives to the treatment of their wastes. Actually, the oil industry has sought solutions to overcome a big environmental problem, i.e., oil field produced water being discharged to the sea. These effluents have organic compounds dissolved, such as polycyclic aromatic hydrocarbons, phenols, benzene, toluene, ethylbenzene and xylenes (BTEX). These compounds are difficult to be removed and have high toxicity. The advanced oxidation processes - AOP are effective to degradation of these organic compounds, because they generate hydroxyl radicals with high potential of oxidation. This work includes the reactor photochemical development applied in the photodegradation treatment (by photo-Fenton process) of wastewaters containing organic compounds dissolved, aiming at treatment and recovery the oil field produced water. The studied reactor allowed the evaluation of two ultraviolet radiation sources that is the main factor to describe the feasibility of the photo¬Fenton treatment, i.e., sun and black light fluorescent lamps, and other relevant variables the process: concentration of reagents, irradiated area and also various reactor configurations to maximize the use of radiation. The organic matter degradation was verified with samples collected during the experimental and analyzed with a total organic carbon analyzer (TOC), which expressed the results in terms of mgC/L. The solar radiation was more effective than radiation from the lamps. it's an important factor for the operation costs cutting. Preliminary experiments applied to oil field produced water treatment have showed satisfactory results, reducing up to 76 % of organic matter
Resumo:
Increasing concern with the environment, in addition to strict laws, has induced the industries to find alternatives to the treatment of their wastes. Actually, the oil industry has sought solutions to overcome a big environmental problem, i.e., oil field produced water being discharged to the sea. These effluents have organic compounds dissolved, such as polycyclic aromatic hydrocarbons, phenols, benzene, toluene, ethylbenzene and xylenes (BTEX). These compounds are difficult to be removed and have high toxicity. The advanced oxidation processes - AOP are effective to degradation of these organic compounds, because they generate hydroxyl radicals with high potential of oxidation. This work includes the reactor photochemical development applied in the photodegradation treatment (by photo-Fenton process) of wastewaters containing organic compounds dissolved, aiming at treatment and recovery the oil field produced water. The studied reactor allowed the evaluation of two ultraviolet radiation sources that is the main factor to describe the feasibility of the photo- Fenton treatment, i.e., sun and black light fluorescent lamps, and other relevant variables the process: concentration of reagents, irradiated area and also various reactor configurations to maximize the use of radiation. The organic matter degradation was verified with samples collected during the experimental and analyzed with a total organic carbon analyzer (TOC), which expressed the results in terms of mgC/L. The solar radiation was more effective than radiation from the lamps. It's an important factor for the operation costs cutting. Preliminary experiments applied to oil field produced water treatment have showed satisfactory results, reducing up to 76 % of organic matter
Resumo:
The diesel combustion form sulfur oxides that can be discharged into the atmosphere as particulates and primary pollutants, SO2and SO3, causing great damage to the environment and to human health. These products can be transformed into acids in the combustion chamber, causing damage to the engines. The worldwide concern with a clean and healthy environment has led to more restrictive laws and regulations regulating the emission levels of pollutants in the air, establishing sulfur levels increasingly low on fuels. The conventional methods for sulfur removal from diesel are expensive and do not produce a zero-level sulfur fuel. This work aims to develop new methods of removing sulfur from commercial diesel using surfactants and microemulsion systems. Its main purpose is to create new technologies and add economic viability to the process. First, a preliminary study using as extracting agent a Winsor I microemulsion system with dodecyl ammonium chloride (DDACl) and nonyl phenol ethoxylated (RNX95) as surfactant was performed to choose the surfactant. The RNX95 was chosen to be used as surfactant in microemulsioned systems for adsorbent surface modification and as an extracting agent in liquid-liquid extraction. Vermiculite was evaluated as adsorbent. The microemulsion systems applied for vermiculite surface modification were composed by RNX95 (surfactant), n-butanol (cosurfactant), n-hexane (oil phase), and different aqueous phases, including: distilled water (aqueous phase),20ppm CaCl2solution, and 1500ppm CaCl2solution. Batch and column adsorption tests were carried out to estimate the ability of vermiculite to adsorb sulfur from diesel. It was used in the experiments a commercial diesel fuel with 1,233ppm initial sulfur concentration. The batch experiments were performed according to a factorial design (23). Two experimental sets were accomplished: the first one applying 1:2 vermiculite to diesel ratio and the second one using 1:5 vermiculite to diesel ratio. It was evaluated the effects of temperature (25°C and 60°C), concentration of CaCl2in the aqueous phase (20ppm and 1500ppm), and vermiculite granule size (65 and 100 mesh). The experimental response was the ability of vermiculite to adsorb sulfur. The best results for both 1:5 and 1:2 ratios were obtained using 60°C, 1500ppm CaCl2solution, and 65 mesh. The best adsorption capacities for 1:5 ratio and for 1:2 ratio were 4.24 mg sulfur/g adsorbent and 2.87 mg sulfur/g adsorbent, respectively. It was verified that the most significant factor was the concentration of the CaCl2 solution. Liquid-liquid extraction experiments were performed in two and six steps using the same surfactant to diesel ratio. It was obtained 46.8% sulfur removal in two-step experiment and 73.15% in six-step one. An alternative study, for comparison purposes, was made using bentonite and diatomite asadsorbents. The batch experiments were done using microemulsion systems with the same aqueous phases evaluated in vermiculite study and also 20ppm and 1500 ppm BaCl2 solutions. For bentonite, the best adsorption capacity was 7.53mg sulfur/g adsorbent with distilled water as aqueous phase of the microemulsion system and for diatomite the best result was 17.04 mg sulfur/g adsorbent using a 20ppm CaCl2solution. The accomplishment of this study allowed us to conclude that, among the alternatives tested, the adsorption process using adsorbents modified by microemulsion systems was considered the best process for sulfur removal from diesel fuel. The optimization and scale upof the process constitutes a viable alternative to achieve the needs of the market
Resumo:
The technology of anaerobic reactors for sanitary wastewater treatment has been extensively developed in Brazil, and today it is practically consolidated. They present several advantages, such as low construction and operating costs, and low sludge production, the anaerobic reactors are an attractive alternative to minimize problematic lack of basic sanitation in urban areas, and also of the rural areas. The anaerobic filters have been widely used in Brazil. It produces an effluent with low concentration of organic matter and solids suspended, besides conserving the nutrients, therefore, it is good for use in irrigation, but the practice must be associated with knowledge of the pathogens presence. The main objective of this study was to evaluate the efficiency of anaerobic filters in removal faecal coliforms and helminth eggs, and to verify if the effluent can be used for agricultural purposes, according to the World Organization of Health (WHO, 1989). The protocol used to enumerate helminths eggs was the modified Bailenger method, (Ayres and Mara, 1996) recommended by WHO for evaluation of raw effluent and treated effluent. The membrane filtration method was utilized to determine the concentrations of faecal coliforms. Three different systems of sewer treatment composed by anaerobic filters were analyzed. The results, in a general analysis, showed that all the researched systems reached a larger removal than 93% to helminth eggs, resulting in an effluent with smaller average than 1 egg/L. One of these systems, Sistema RN, reached a larger removal than 99%, confirming the good performance of the anaerobic filters in removal helminths eggs. Even with low concentrations of eggs in the influent, the filters were capable to remove this parameter efficiently. About faecal coliforms, it was observed for all the researched systems an effluent with 106 CFU/100mL. The high concentrations to faecal coliforms in the effluent just allow reuse for restricted irrigation, in agreement with the guidelines of WHO. Although the researched systems have not removed faecal coliforms efficiently, the results indicated a good efficiency of the anaerobic filters in removal helminth eggs
Resumo:
The aim of this approach is to describe the design and construction of a low-cost automated water sampler prototype. In recent years, there is an increasing need on the use of automated equipments for hydro climatic variables to be use in urban and rural environments. Such devices are always used to provide measured information which is of crucial importance on the development of water resources strategies at watershed scale. Actually, many research and water public institutions have been using these kinds of equipments. In most of the cases, automated equipments are expensive and need to be imported, generating a situation of technologic dependency. The prototype is based on an electronic system which controls a peristaltic pump functioning, five solenoid valves and an ultrasonic sensor connected to a datalloger. An interface with the user allows communication with a PC, when the equipment functioning parameters can be provided. The equipment has a hydraulic module composed by a 12V peristaltic pump connected to a distribution circuit composed by five solenoid valves, one of them being used to clean the circuit before each sampling procedure. Samples are collected by four 1.95 polyethylene bottles. The sampler body was made of acrylic material, with a cylindrical shape, and dimensions 0.72 m and 0.38 m height and diameter, respectively. The weight of the equipment without samples is approximately 15 kg, which infers to its portability. The prototype development total cost budget was approximately US$ 1,560.00. Laboratory tests aimed to evaluate the equipment performance and functioning demonstrated satisfactory results
Resumo:
Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.
Resumo:
The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.
Resumo:
Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.
Resumo:
Wetlands systems are considered nowadays as a treatment method that uses simple, easy operation and low cost technology, which has been used in various parts of the world and also in Brazil. Used alone or as a complement to other types of treatment systems, once it effectively removes nutrients, pathogens and other pollutants in the water. Due to the high complexity found in wetlands, making it difficult to predict the response of the system to treat wastewater, one should consider as ideal to base the sizing of the wetland system over the necessary removal of this parameter instead of scaling it from empiricism. The study was conducted to determine the coefficient of bacterial decrease in the Wetland unit located at Ponta Negra Station Sewage Treatment, located in Natal, the coastal region of Rio Grande do Norte. The most representative model to determine the bacterial decrease in this system was the one from Chick for hydraulic piston system. Kb of 0.37 d-1 were found for the flow rate of 15m³/d, while for the system operating at maximum design flow, 30m³/d, the Kb of 0.98 d-1 was found
Resumo:
The management of water resources in the river basin level, as it defines the Law nº 9433/97, requires the effective knowledge of the processes of hydrological basin, resulting from studies based on consistent series of hydrological data that reflect the characteristics of the basin. In this context, the objective of this work was to develop the modeling of catchment basin of the river Jundiaí - RN and carry out the study of attenuation of a flood of the dam Tabatinga, by means of a monitoring project of hydrological data and climatology of the basin, with a view to promoting the development of research activities by applying methodologies unified and appropriate for the assessment of hydrological studies in the transition region of the semiarid and the forest zone on the coast of Rio Grande do Norte. For the study of the hydrological characteristics of the basin was conducted the automatic design of the basin of the river Jundiaí, with the aid of programs of geoprocessing, was adopted a hydrological model daily, the NRCS, which is a model determined and concentrated. For the use of this model was necessary to determine some parameters that are used in this model, as the Curve Number. Having in mind that this is the first study that is being conducted in the basin with the employment of this model, it was made sensitivity analysis of the results of this model from the adoption of different values of CN, situated within a range appropriate to the conditions of use, occupation and the nature of the soil of this basin. As the objective of this study was also developing a simulation model of the operation of the Tabatinga dam and with this flood control caused in the city of Macaíba, it was developed a mathematical model of fluid balance, developed to be used in Microsoft Excel. The simulation was conducted in two phases: the first step was promoted the water balance daily that allowed the analysis of the sensitivity of the model in relation to the volume of waiting, as well as the determination of the period of greatest discharges daily averages. From this point, it was assumed for the second stage, which was in the determination of the hydrograph of discharges effluent slots, that was determined by means of the fluid balance time, on the basis of the discharges effluents generated by a mathematical equation whose parameters were adjusted according to the hydrograph daily. Through the analyzes it was realized that the dam Tabatinga only has how to carry out the attenuation of floods through the regularization of the volume of waiting, with this there is a loss of approximately 56.5% on storage capacity of this dam, because for causing the attenuation effect of filled the shell of this dam has to remain more than 5m below the level of the sill, representing at least 50.582.927m3. The results obtained with the modeling represents a first step in the direction of improving the level of hydrological information about the behavior of the basins of the semiarid. In order to monitor quantitatively the hydrographic basin of the river Jundiaí will be necessary to install a rain gauge register, next to the Tabatinga dam and a pressure transducer, for regular measurements of flow in the reservoir of the dam. The climatological data will be collected in full automatic weather station installed in Agricultural School Jundiaí
Resumo:
The state of Rio Grande do Norte, possessor of an extremely irregular regime of rains, has the necessity of enlarge and specify the researches about its own hydro-climatic conditions, to achieve trustworthy results that are able to minimize the adversities imposed by these conditions and make possible the implementation of a better planning in the economic activities and of subsistence that somehow utilize of the multiple uses of hydro resources of the State. This way, the daily values observed from the pluviometric series of 166 posts, with 45 years uninterrupted of historic data, were adjusted to the incomplete gamma function to the determination of the probability of rain in the 36 period of ten days in which the year was divided. To the attainment of the α and β parameters of this function it was applied the method of the maximum verisimilitude allowing, in the end, to analyze the temporal and spatial distribution of the rain in the level of 75% of probability. The values of potential evapo-transpiration were calculated by the Linacre method that, through the SURFER software, were confronted with the dependant rain, obtaining, in this way, the spatialization of the potential hydro availability, which the values can be known to any period of ten days of the year, city and/or region of the state of Rio Grande do Norte. With the identification of the main meteorological systems that act in the State, we sought to better comprehend how this systems interfere, in the irregular regime of rain, in the situations of several clime in the major part of Rio Grande do Norte and in the hydro regional balance. And, finally, with these data in hand and with the generated maps, we verified that space-temporal distribution of the rain and of the potential hydro availability were heterogeneous in the whole State, mainly in the West and Central regions, inserted in potiguar s semi-arid, which, after the period of the rains station, suffers with dry season and length drought during the rest of the year