993 resultados para Session variability compensation
Resumo:
This work addresses the joint compensation of IQimbalances and carrier phase synchronization errors of zero- IF receivers. The compensation scheme based on blind-source separation which provides simple yet potent means to jointly compensate for these errors independent of modulation format and constellation size used. The low-complexity of the algorithm makes it a suitable option for real-time deployment as well as practical for integration into monolithic receiver designs.
Resumo:
I and Q Channel phase and gain misniatches are of great concern in communications receiver design. In this paper we analyse the effects of I and Q channel mismatches and propose a low-complexity blind adaptive algorithm to minimize this problem. The proposed solution consists of two, 2-tap adaptive filters, arranged in Adaptive Noise Canceller (ANC) set-up, with the output of one cross-fed to the input of the other. The system works as a de-correlator eliminating I and Q mismatch errors.
Resumo:
Tese de doutoramento, Ciências Geofísicas e da Geoinformação (Deteção Remota), Universidade de Lisboa, Faculdade de Ciências, 2015
Resumo:
Thought speed and variability are purportedly common features of specific psychological states, such as mania and anxiety. The present study explored the independent and combinational influence of these variables upon condition-specific symptoms and affective state, as proposed by Pronin and Jacobs’ (Perspect Psychol Sci, 3:461–485, 2008) theory of mental motion. A general population sample was recruited online (N = 263). Participants completed a thought speed and variability manipulation task, inducing a combination of fast/slow and varied/repetitive thought. Change in mania and anxiety symptoms was assessed through direct self-reported symptom levels and indirect, processing bias assessment (threat interpretation). Results indicated that fast and varied thought independently increased self-reported mania symptoms. Affect was significantly less positive and more negative during slow thought. No change in anxiety symptoms or threat interpretation was found between manipulation conditions. No evidence for the proposed combinational influence of speed and variability was found. Implications and avenues for therapeutic intervention are discussed.
Resumo:
Senior thesis written for Oceanography 445
Resumo:
Global navigation satellite system (GNSS) receivers require solutions that are compact, cheap and low-power, in order to enable their widespread proliferation into consumer products. Furthermore, interoperability of GNSS with non-navigation systems, especially communication systems will gain importance in providing the value added services in a variety of sectors, providing seamless quality of service for users. An important step into the market for Galileo is the timely availability of these hybrid multi-mode terminals for consumer applications. However, receiver architectures that are amenable to high-levels of integration will inevitably suffer from RF impairments hindering their easy widespread use in commercial products. This paper studies and presents analytical evaluations of the performance degradation due to the RF impairments and develops algorithms that can compensate for them in the DSP domain at the base band with complexity-reduced hardware overheads, hence, paving the way for low-power, highly integrated multi-mode GNSS receivers.
Resumo:
Senior thesis written for Oceanography 445
Resumo:
This paper presents the design analysis of novel tunable narrow-band bandpass sigma-delta modulators, that can achieve concurrent multiple noise-shaping for multi-tone input signals. This approach utilises conventional comb filters in conjunction with FIR, or allpass IIR fractional delay filters, to deliver the desired nulls for the quantisation noise transfer function. Detailed simulation results show that FIR fractional delay comb filter based sigma-delta modulators tune accurately to most centre frequencies, but suffer from degraded resolution at frequencies close to Nyquist. However, superior accuracies are obtained from their allpass IIR fractional delay counterpart at the expense of a slight shift in noise-shaping bands at very high frequencies.
Resumo:
This paper presents compensation of all undesired effects (Power Amplifier (PA) nonlinearity, transmitter and receiver antenna crosstalk, before-PA nonlinear crosstalk, Multiple Input Multiple Output (MIMO) channel fading and crosstalk) in MIMO Orthogonal Frequency Division Multiplex (OFDM) wireless systems. It has been demonstrated that reduced-complexity Crossover Digital Predistortion (CO-DPD) algorithm on transmitter side and Matrix Inversion algorithm on receiver side can suppress almost all undesired effects introduced by transmitter, channel and receiver in 4×4 MIMO OFDM System that can be used in modern wireless system applications. A significant complexity reduction is achieved due to the fact that Digital Signal Processing (DSP) during CO-DPD process on transmitter side is done with real instead of complex numbers.
Resumo:
This article reconsiders the House of Lords decision in Rees v. Darlington Memorial Hospital NHS Trust (2003) and the decision to award a conventional award of £15,000 in all cases of failed sterilisation resulting in the birth of an unwanted child. In so doing, it briefly recites the history of the Wrongful Conception action and the unique facts of Rees. It then goes on the consider the implications of two fundamental aspects of the judgment. Firstly, it looks at the 'conventional award' itself and considers the reasoning behind the award and the effect that it has on our understanding of (particularly women's) reproductive autonomy. Secondly, it analyses the rather 'unique' judgment of Lord Scott and his decision to evaluate these cases using the possessory analogy of an unwanted foal; particular focus is given to the notion of parental 'choice' in these cases and whether mitigation (i.e. abortion or adoption) can ever be considered "reasonable".
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-03
Resumo:
Objective: The Finometer (FMS, Finapres Measurement Systems, Amsterdam) records the beat-to-beat finger pulse contour and has been recommended for research studies assessing shortterm changes of blood pressure and its variability. Variability measured in the frequency domain using spectral analysis requires that the impact of breathing be restricted to high frequency spectra (> 0.15 Hz) so data from participants needs to be excluded when the breathing impact occurs in the low frequency spectra (0.04 - 0.15 Hz). This study tested whether breathing frequency can be estimated from standard Finometer recordings using either stroke volume oscillation frequency or spectral stroke volume variability maximum scores. Methods: 22 healthy volunteers were tested for 270s in the supine and upright positions. Finometer recorded the finger pulse contour and a respiratory transducer recorded breathing. Stoke volume oscillation frequency was calculated manually while the stroke volume spectral maximums were obtained using the software Cardiovascular Parameter Analysis (Nevrokard Kiauta, Izola, Slovenia). These estimates were compared to the breathing frequency using the Bland-Altman procedures. Results: Stroke volume oscillation frequency estimated breathing frequency to <±10% 95% levels of agreement in both supine (-7.7 to 7.0%) and upright (-6.7 to 5.4%) postures. Stroke volume variability maximum scores did not accurately estimate breathing frequency. Conclusions: Breathing frequency can be accurately derived from standard Finometer recordings using stroke volume oscillations for healthy individuals in both supine and upright postures. The Finometer can function as a standalone instrument in blood pressure variability studies and does not require support equipment to determine breathing frequency.
Resumo:
The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke volume oscillations but not spectral frequency variability stroke volume measures can be used to estimate the breathing frequency. This study investigated with the same recordings whether heart period oscillations or spectral heart rate variability measures could function as estimators of breathing frequency. Continuous 270 s cardiovascular recordings were obtained from 22 healthy adult volunteers in the supine and upright postures. Breathing was recorded simultaneously. Breathing frequency and heart period oscillation frequency were calculated manually, while heart rate variability spectral maximums were obtained using heart rate variability software. These estimates were compared to the breathing frequency using the Bland–Altman agreement procedure. Estimates were required to be \±10% (95% levels of agreement). The 95% levels of agreement measures for the heart period oscillation frequency (supine: -27.7 to 52.0%, upright: -37.8 to 45.9%) and the heart rate variability spectral maximum estimates (supine: -48.7 to 26.5% and -56.4 to 62.7%, upright: -37.8 to 39.3%) exceeded 10%. Multiple heart period oscillations were observed to occur during breathing cycles. Both respiratory and non-respiratory sinus arrhythmia was observed amongst healthy adults. This observation at least partly explains why heart period parameters and heart rate variability parameters are not reliable estimators of breathing frequency. In determining the validity of spectral heart rate variability measurements we suggest that it is the position of the spectral peaks and not the breathing
Resumo:
Understanding the impact of training sessions on the immune response is crucial for the adequate periodization of training, to prevent both a negative influence on health and a performance impairment of the athlete. This study evaluated acute systemic immune cell changes in response to an actual swimming session, during a 24-h recovery period, controlling for sex, menstrual cycle phases, maturity, and age group. Competitive swimmers (30 females, 15 ± 1.3 years old; and 35 males, 16.5 ± 2.1 years old) performed a high-intensity training session. Blood samples were collected before, immediately after, 2 h after, and 24 h after exercise. Standard procedures for the assessment of leukogram by automated counting (Coulter LH 750, Beckman) and lymphocytes subsets by flow cytometry (FACS Calibur BD, Biosciences) were used. Subjects were grouped according to competitive age groups and pubertal Tanner stages. Menstrual cycle phase was monitored. The training session induced neutrophilia, lymphopenia, and a low eosinophil count, lasting for at least 2 h, independent of sex and maturity. At 24 h postexercise, the acquired immunity of juniors (15-17 years old), expressed by total lymphocytes and total T lymphocytes (CD3+), was not fully recovered. This should be accounted for when planning a weekly training program. The observed lymphopenia suggests a lower immune surveillance at the end of the session that may depress the immunity of athletes, highlighting the need for extra care when athletes are exposed to aggressive environmental agents such as swimming pools