982 resultados para Semi-implicit methods
Resumo:
Objectives:¦The aim of this study was to estimate the prevalence of subclinical small joint synovitis detected by ultrasonography in patients with axial SpA, and to evaluate their relevance in terms of function or and disease activity.¦Methods:¦Forty axial SpA patients, 40 RA and 20 healthy subjects were evaluated by ultrasonography, using a reproducible semi-quantitative score by B-mode and Doppler, for synovitis, while disease activity and function were assessed using validated instruments (DAS28, BASDAI, BASFI, m-SACRAH and HAQ).¦Results:¦Median B-mode score were respectively 8.2 for axial SpA, 11.5 for RA and 6.0 for healthy subjects, corresponding to a prevalence of clinical significant synovitis of respectively 37.5%, 60% and 11% for a level of significance at > 8 chosen to¦classify as active > 75% of RA patient with DAS28 >2.6 and < 10% of controls. Addtionally, Doppler was positive in 8% of SpA, 30 % of RA and none of the healthy subjects. Echographic synovitis correlated with disease activity (DAS28) and function¦(HAQ, mSACRAH) in RA patients, but no correlation were found for SpA patients with disease activity (BASDAI) or function (BASFI, HAQ, mSACRAH). Cases of synovitis using classification by Doppler positivity were insufficient to allow any¦statistical analysis.¦Conclusions:¦B-mode ultrasonographic evaluation can demonstrate subclinical synovitis in almost 40% of SpA patients, but they do not appear to correlate with disease activity or function on the contrary to what is observed in RA patients, representing potentially different processes
Resumo:
Oscillations have been increasingly recognized as a core property of neural responses that contribute to spontaneous, induced, and evoked activities within and between individual neurons and neural ensembles. They are considered as a prominent mechanism for information processing within and communication between brain areas. More recently, it has been proposed that interactions between periodic components at different frequencies, known as cross-frequency couplings, may support the integration of neuronal oscillations at different temporal and spatial scales. The present study details methods based on an adaptive frequency tracking approach that improve the quantification and statistical analysis of oscillatory components and cross-frequency couplings. This approach allows for time-varying instantaneous frequency, which is particularly important when measuring phase interactions between components. We compared this adaptive approach to traditional band-pass filters in their measurement of phase-amplitude and phase-phase cross-frequency couplings. Evaluations were performed with synthetic signals and EEG data recorded from healthy humans performing an illusory contour discrimination task. First, the synthetic signals in conjunction with Monte Carlo simulations highlighted two desirable features of the proposed algorithm vs. classical filter-bank approaches: resilience to broad-band noise and oscillatory interference. Second, the analyses with real EEG signals revealed statistically more robust effects (i.e. improved sensitivity) when using an adaptive frequency tracking framework, particularly when identifying phase-amplitude couplings. This was further confirmed after generating surrogate signals from the real EEG data. Adaptive frequency tracking appears to improve the measurements of cross-frequency couplings through precise extraction of neuronal oscillations.
Resumo:
This paper characterizes and evaluates the potential of three commercial CT iterative reconstruction methods (ASIR?, VEO? and iDose(4 ()?())) for dose reduction and image quality improvement. We measured CT number accuracy, standard deviation (SD), noise power spectrum (NPS) and modulation transfer function (MTF) metrics on Catphan phantom images while five human observers performed four-alternative forced-choice (4AFC) experiments to assess the detectability of low- and high-contrast objects embedded in two pediatric phantoms. Results show that 40% and 100% ASIR as well as iDose(4) levels 3 and 6 do not affect CT number and strongly decrease image noise with relative SD constant in a large range of dose. However, while ASIR produces a shift of the NPS curve apex, less change is observed with iDose(4) with respect to FBP methods. With second-generation iterative reconstruction VEO, physical metrics are even further improved: SD decreased to 70.4% at 0.5 mGy and spatial resolution improved to 37% (MTF(50%)). 4AFC experiments show that few improvements in detection task performance are obtained with ASIR and iDose(4), whereas VEO makes excellent detections possible even at an ultra-low-dose (0.3 mGy), leading to a potential dose reduction of a factor 3 to 7 (67%-86%). In spite of its longer reconstruction time and the fact that clinical studies are still required to complete these results, VEO clearly confirms the tremendous potential of iterative reconstructions for dose reduction in CT and appears to be an important tool for patient follow-up, especially for pediatric patients where cumulative lifetime dose still remains high.
Resumo:
n this paper the iterative MSFV method is extended to include the sequential implicit simulation of time dependent problems involving the solution of a system of pressure-saturation equations. To control numerical errors in simulation results, an error estimate, based on the residual of the MSFV approximate pressure field, is introduced. In the initial time steps in simulation iterations are employed until a specified accuracy in pressure is achieved. This initial solution is then used to improve the localization assumption at later time steps. Additional iterations in pressure solution are employed only when the pressure residual becomes larger than a specified threshold value. Efficiency of the strategy and the error control criteria are numerically investigated. This paper also shows that it is possible to derive an a-priori estimate and control based on the allowed pressure-equation residual to guarantee the desired accuracy in saturation calculation.
Resumo:
Background: patients with axial Spondyloarthritis (SD), even withoutany obvious peripheral joint synovitis, often complain of pain in thejoints of arms and legs. Several musculoskeletal ultrasound (US)scores developed in rheumatoid arthritis have demonstrated theircapacity of discovering subclinical synovitis which were relevant interm of disease activity and for treatment strategies. None of thesescores however have been, to our knowledge, applied tospondyloarthritis patients.Objectives: to determine if subclinical synovitis can be detected byechography in patients with SD and if these synovitis are relevantcompared with RA and controls.Methods: the Swiss Sonography in Arthritis and Rheumatism(SONAR) group has developed a reproducible semi-quantitative scorefor RA using OMERACT criteria for synovitis. The score includes Bmode and Doppler mode. 35 out of 40 enrolled SD patients fulfillingthe 2010 diagnostic criteria were evaluated according to the SONARscore. In none of them, peripheral synovitis was clearly demonstrated,although some have or reported recurrent peripheral joint pain. Thescore was also applied to 20 matched controls and 40 consecutive RApatients (RA). 19 of them were in remission (DAS: <2.6), 10 with alow activity (DAS: 2.6 <>3.4) and 11 with a moderate activity disease(DAS: 3.5 <>5.1). All the patients and the controls had a completeclinical, biological and auto-evaluation assessment (joint pain andswelling counts, DAS28, HAQ, BASDAI BASMI, BASFI, m-SACRAH).The ultra-sonographer was blind to all these parameters.Results: a B mode score >8, was set up as a cut-off value forsignificant synovitis as only 10% of the controls (median: 5.9 ± 2.2)and 90% of active RA had a higher score .34% of SD had significantsynovitis which remained mostly mild. Their median B mode score(12 ± 1.6) was higher but not significantly than in remission Ra (7.1 ±3.4). Only active RA (DAS >3.5) had significant higher echographicscores: B mode (17 ± 11), Doppler score and cumulative score forsynovitis grade >1. BASDAI, BASFI, BASMI, m-SACRAH, DAS28 andCRP were not significantly different in SD patients with or withoutsynovitis.Conclusions: some patients with axial Spondyloarthritis havesubclinical but significant peripheral synovitis detected by echography.The impact of these synovitis remains uncertain as their presencedoes not seem to significantly influence disease activity and functionevaluation tools.