980 resultados para S.aureus
Resumo:
This study analyzed the development of bacterial endocarditis following dental extraction in rats with periodontal disease. Periodontal disease was produced in rats by tying silk ligatures around the two maxillary first molars, and placing the animals on a high sucrose diet. Sterile aortic valve vegetations were produced by means of a transaortic catheter, and 24 hours later the maxillary first molars were extracted. The animals were killed 72 hours after the extractions. In rats with periodontal disease induced for 10 and 14 weeks, extractions resulted in an incidence of bacterial endocarditis of 24% and 50%, respectively, most of which were due to streptococcal species (two were caused by Staphylococcus [corrected] aureus). The difference, though not statistically significant (p = 0.10, chi 2 with Yates correction), shows a trend toward increased incidence of endocarditis with increasing severity of periodontal disease. This model demonstrates that one can reliably induce bacterial endocarditis after dental extractions in rats with periodontal disease.
Resumo:
O principal objetivo deste estudo é identificar, na literatura, artigos sobre a ocorrência de contaminação das superfícies inanimadas e uma possível disseminação de bactérias resistentes no ambiente hospitalar. Realizou-se um levantamento bibliográfico de artigos publicados nas bases de dados LILACS, MEDLINE, Science Direct, SCOPUS e ISI Web of Knowledge, entre 2000 e 2008. Foram selecionados e analisados vinte e um artigos. Nos estudos analisados, realçou-se a presença de bactérias em monitores, grades de cama, mesas, torneiras, telefones, teclados de computador e outros objetos. Houve predominância de Staphylococcus aureus resistente à meticilina, Clostridium difficile, Acine-to-bacter baumannii e Enterococcus resistentes à vancomicina, sendo fator preditivo a ocupação prévia por pacientes colonizados por tais microrganismos. Verificou-se semelhança entre as cepas isoladas de pacientes colonizados e/ou infectados e as cepas do ambiente por tipificação molecular. Essas evidências reforçam a necessidade de conhecimento e controle de fontes de patógenos no ambiente hospitalar.
Resumo:
Objetivou-se descrever e comparar as características clínicas, laboratoriais e assistenciais de RN que apresentaram sepse comprovada tardia e de RN que apresentaram sepse não comprovada tardia. Em seguida, avaliar se houve diferença entre os grupos, além de descrever os germes prevalentes na unidade neonatal estudada. Estudo descritivo, envolvendo 168 casos. Observou-se que 33,3% tiveram sepse tardia provada. A idade no momento da sepse, o tempo total de internação, a quantidade total de neutrófilos, a quantidade de neutrófilos imaturos e o valor da PC-r mostraram bons parâmetros na diferenciação entre os dois grupos quando analisados de forma isolada. A Klebisiella pneumoniae, o Staphylococcus coagulase negativo e o S. aureus foram as bactérias mais comumente isoladas.
Resumo:
BACKGROUND: The clinical profile and outcome of nosocomial and non-nosocomial health care-associated native valve endocarditis are not well defined. OBJECTIVE: To compare the characteristics and outcomes of community-associated and nosocomial and non-nosocomial health care-associated native valve endocarditis. DESIGN: Prospective cohort study. SETTING: 61 hospitals in 28 countries. PATIENTS: Patients with definite native valve endocarditis and no history of injection drug use who were enrolled in the ICE-PCS (International Collaboration on Endocarditis Prospective Cohort Study) from June 2000 to August 2005. MEASUREMENTS: Clinical and echocardiographic findings, microbiology, complications, and mortality. RESULTS: Health care-associated native valve endocarditis was present in 557 (34%) of 1622 patients (303 with nosocomial infection [54%] and 254 with non-nosocomial infection [46%]). Staphylococcus aureus was the most common cause of health care-associated infection (nosocomial, 47%; non-nosocomial, 42%; P = 0.30); a high proportion of patients had methicillin-resistant S. aureus (nosocomial, 57%; non-nosocomial, 41%; P = 0.014). Fewer patients with health care-associated native valve endocarditis had cardiac surgery (41% vs. 51% of community-associated cases; P < 0.001), but more of the former patients died (25% vs. 13%; P < 0.001). Multivariable analysis confirmed greater mortality associated with health care-associated native valve endocarditis (incidence risk ratio, 1.28 [95% CI, 1.02 to 1.59]). LIMITATIONS: Patients were treated at hospitals with cardiac surgery programs. The results may not be generalizable to patients receiving care in other types of facilities or to those with prosthetic valves or past injection drug use. CONCLUSION: More than one third of cases of native valve endocarditis in non-injection drug users involve contact with health care, and non-nosocomial infection is common, especially in the United States. Clinicians should recognize that outpatients with extensive out-of-hospital health care contacts who develop endocarditis have clinical characteristics and outcomes similar to those of patients with nosocomial infection. PRIMARY FUNDING SOURCE: None.
Resumo:
Background: Negative pressure wound treatment is increasingly used through a Vacuum-Assisted Closure (VAC) device in complex wound situations. For this purpose, sterile polyurethane (PU) and polyvinyl alcohol (PVA) foam dressings are fitted to the wound size and covered with an adhesive drape to create an airtight seal. Little information exists about the type and quantity of microorganisms within the foams. Therefore, we investigated VAC foams after removal from the wound using a validated method (sonication) to detect the bacterial bioburden in the foam consisting as microbial biofilms.Methods: We prospectively included VAC foams (PU and PVA, KCI, Rümlamg, Switzerland) without antibacterial additions (e.g. silver), which were removed from wounds in patients with chronic ulcers from January 2007 through December 2008. Excluded were patients with acute wound infection, necrotizing fasciitis, underlying osteomyelitis or implant. Removed foams from regular changes of dressing were aseptically placed in a container with 100 ml sterile Ringer's solution. Within 4 hours after removal, foams were sonicated for 5 min at 40 kHz (as described in NEJM 2007;357:654). The resulting sonication fluid was cultured at 37°C on aerobic blood agar plates for 5 days. Microbes were quantified as No. of colony-forming units (CFU)/ml sonication fluid and identified to the species level.Results: A total of 68 foams (38 PU and 30 PVA) from 55 patients were included in the study (median age 71 years; range 33-88 years, 57% were man). Foams were removed from the following anatomic sites: sacrum (n=29), ischium (n=18), heel (n=13), calves (n=6) and ankle (n=2). The median duration of being in place was 3 days (range, 1-8 days). In all 68 foams, bacteria were found in large quantities (median 105 CFU/ml, range 102-7 CFU/ml sonication fluid. No differences were found between PU and PVA foams. One type of organisms was found in 11 (16%), two in 17 (24%) and 3 or more in 40 (60%) foams. Gram-negative rods (Escherichia coli, Proteus mirabilis, Klebsiella pneumoniae, Acinetobacter baumanii, Pseudomonas aeruginosa) were isolated in 70%, followed by Staphylococcus aureus (20%), koagulase-negative staphylococci, streptococci (8%), and enterococci (2%).Conclusion: With sonication, a high density of bacteria present in VAC foams was demonstrated after a median of 3 days. Future studies are needed to investigate whether antimicrobial-impregnated foams can reduce the bacterial load in foams and potentially improve wound healing.