999 resultados para Resistências elétricas


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of low quality water for agriculture should be performed with care to avoiding excessive accumulation of salts in the soil so not to harm crop development. In order to evaluate the performance of beets under the infl uence of low water quality, an experiment was conducted in a greenhouse of the Department of Agricultural Engineering, Universidade Estadual Paulista in Botucatu, Brazil, from April to July 2012. We used the beet (Beta vulgaris L.) in a completely randomized design with 6 treatments and 5 replications, totaling 30 plots. Treatments consisted of NaCl solutions at different concentrations (2.0, 3.0, 4.0, 5.0 and 6.0 dS m-1) plus a control treatment corresponding to water with no additional salt and electrical conductivity of roughly 0.26 dS m-1. Variables evaluated were total production, commercial production, plant height, number of plants and root diameter. Production of the beet crop was affected by the increasing salinity of irrigation water, characterized by reduced root production of the beets. Total and commercial production showed reductions of 8.82 and 12.2% in accordance with the unit increase of salinity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrical measures of the soil have been used as variables that correlate with its characteristics. This study aimed at developing an electrical capacitance sensor of low cost, to evaluate its performance on the field and verify the correlation between the measurements of electrical capacitance with physical properties (sand, silt and clay) and chemical properties of soil (pH, MO, P resin, H + Al, K, Ca, Mg, SB, CTC and V%) and the moisture content. The data sampling was performed at the farm named "Capão da Onça" which belongs to the State University of Ponta Grossa. The samples collection was conducted in an area of approximately 13 hectares, totalizing 81 samples. In each sampling the electrical capacitance of the soil was measured. After the sensor withdrawal, soil samples were collected and sent to be analysed in the laboratory of the College of Agronomics Science of the Paulista State University. The measuring instrument used to collect data on electric capacitance of the soil a digital multimeter was used. The data were submitted to the analysis of correlation and regression. The developed system presented a low cost and it was capable to measuring variation of the electrical capacitance of the soil. The obtained measures satisfactorily correlated with the levels of clay and sand, and weakly with the moisture content. This had demonstrated the possibility to use a sensor to verify the soil texture in not homogeneous areas. The measures of the electrical capacitance of the soil obtained by the sensor had significantly correlated with the soil attributes: calcium, magnesium, pH, SB and CTC. These results had demonstrated the possibility to use a sensor for soil fertility control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia de Produção - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tape Casting proved to be an effective method for the production of thick films of CeO2 pure and doped with La. For this study, the nanoparticles used to form the slurry were synthesizes by the H-M method, at 100°C for 8 minutes, using KOH mineralizer. The slurry was made in aqueous solvent, requiring optimal control of surroundings conditions so that the produced tape has conditions to be studied. However, there's no toxicity or flammability in the film made by such solvent, being pleasing to the environment. The structural, optical and electrical properties of the films obtained by the Tape Casting process were studied by the methods of X-ray diffraction, scanning electron microscopy, specific surface area, Ultraviolet-visible spectroscopy and voltage-current measures, varying the electric field and frequency. From the results obtained by laboratory experiments, based on the literature, it was possible to reveal and understand some CeO2 features pure and doped with La

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tape Casting proved to be an effective method for the production of thick films of CeO2 pure and doped with La. For this study, the nanoparticles used to form the slurry were synthesizes by the H-M method, at 100°C for 8 minutes, using KOH mineralizer. The slurry was made in aqueous solvent, requiring optimal control of surroundings conditions so that the produced tape has conditions to be studied. However, there's no toxicity or flammability in the film made by such solvent, being pleasing to the environment. The structural, optical and electrical properties of the films obtained by the Tape Casting process were studied by the methods of X-ray diffraction, scanning electron microscopy, specific surface area, Ultraviolet-visible spectroscopy and voltage-current measures, varying the electric field and frequency. From the results obtained by laboratory experiments, based on the literature, it was possible to reveal and understand some CeO2 features pure and doped with La

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years, there was an increase of ancillary service loads, such as signaling systems, inspection robots, surveillance cameras, and other monitoring devices distributed along high-voltage transmission lines which require low-power dc voltage supplies. This paper investigates the use of the induced voltage in the shield wires of an overhead 525 kV transmission line as a primary power source. Since phase current variations throughout the day affect the induced voltage in the overhead ground wire, a step-down dc-dc converter is used after rectification of the ac voltage to provide a regulated dc output voltage. The initial encouraging results obtained indicate that this form of power supply can be a feasible and cost-effective alternative for feeding small ancillary service loads. The simulation results are validated by field measurements as well as the installation of a 200 W voltage stabilization system prototype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Muitas pesquisas estão sendo desenvolvidas buscando nos sistemas inteligentes soluções para diagnosticar falhas em máquinas elétricas. Estas falhas envolvem desde problemas elétricos, como curto-circuito numa das fases do estator, ate problemas mecânicos, como danos nos rolamentos. Dentre os sistemas inteligentes aplicados nesta área, destacam-se as redes neurais artificiais, os sistemas fuzzy, os algoritmos genéticos e os sistemas híbridos, como o neuro-fuzzy. Assim, o objetivo deste artigo é traçar um panorama geral sobre os trabalhos mais relevantes que se beneficiaram dos sistemas inteligentes nas diferentes etapas de análise e diagnóstico de falhas em motores elétricos, cuja principal contribuição está em disponibilizar diversos aspectos técnicos a fim de direcionar futuros trabalhos nesta área de aplicação.