979 resultados para Relations with the Soviet bloc
Resumo:
PURPOSE: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. METHODS: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). RESULTS: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. CONCLUSIONS: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.
Resumo:
The silicon photomultiplier (SiPM) is a novel detector technology that has undergone a fast development in the last few years, owing to its single-photon resolution and ultra-fast response time. However, the typical high dark count rates of the sensor may prevent the detection of low intensity radiation fluxes. In this article, the time-gated operation with short active periods in the nanosecond range is proposed as a solution to reduce the number of cells fired due to noise and thus increase the dynamic range. The technique is aimed at application fields that function under a trigger command, such as gated fluorescence lifetime imaging microscopy.
Resumo:
The CD8 molecule is a glycoprotein expressed on a subset of mature T lymphocytes. It has been postulated to be a receptor for class I major histocompatibility complex molecules. In the mouse, CD8 is a heterodimer composed of Ly-2 and Ly-3 chains. We have isolated and analyzed cDNA and cosmid clones corresponding to the Ly-3 subunit. One of the isolated, cosmid clones was subsequently transfected, alone or in combination with the Ly-2 gene, into mouse Ltk- cells. Analysis of the Ly-2,3 molecules expressed at the surface of the double transfectants indicated that they are serologically and biochemically indistinguishable from their normal counterparts expressed on lymphoid cells. Ltk- cells transfected with the Ly-2 gene alone were shown to react with a subset of anti-CD8 monoclonal antibodies whereas Ly-3 transfectants did not stain with any of the anti-Ly-3 antibodies employed in this study. Since at least one of these antibodies (53-5.8) has been previously shown to recognize an epitope which is retained on the Ly-3 subunit after dissociation of the heterodimeric Ly-2,3 complex, these observations suggest that the expression of the Ly-2 polypeptide is required to permit the detectable cell surface expression of the antigenic determinants carried by the Ly-3 subunit.