This paper presents a historical examination of employment in old age in Spain, in order to characterize this labour segment and identify and analyse its specific problems. One of these problems is the life-cycle deskilling process, already shown for certain national cases. This study explores whether this hypothesis also holds in Spain. The perspective used is essentially quantitative, as our analysis is based on the age-profession tables in Spanish population censuses from 1900 to 1970.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Accurate automatic segmentation of the caudate nucleus in magnetic resonance images (MRI) of the brain is of great interest in the analysis of developmental disorders. Segmentation methods based on a single atlas or on multiple atlases have been shown to suitably localize caudate structure. However, the atlas prior information may not represent the structure of interest correctly. It may therefore be useful to introduce a more flexible technique for accurate segmentations. Method We present Cau-dateCut: a new fully-automatic method of segmenting the caudate nucleus in MRI. CaudateCut combines an atlas-based segmentation strategy with the Graph Cut energy-minimization framework. We adapt the Graph Cut model to make it suitable for segmenting small, low-contrast structures, such as the caudate nucleus, by defining new energy function data and boundary potentials. In particular, we exploit information concerning the intensity and geometry, and we add supervised energies based on contextual brain structures. Furthermore, we reinforce boundary detection using a new multi-scale edgeness measure. Results We apply the novel CaudateCut method to the segmentation of the caudate nucleus to a new set of 39 pediatric attention-deficit/hyperactivity disorder (ADHD) patients and 40 control children, as well as to a public database of 18 subjects. We evaluate the quality of the segmentation using several volumetric and voxel by voxel measures. Our results show improved performance in terms of segmentation compared to state-of-the-art approaches, obtaining a mean overlap of 80.75%. Moreover, we present a quantitative volumetric analysis of caudate abnormalities in pediatric ADHD, the results of which show strong correlation with expert manual analysis. Conclusion CaudateCut generates segmentation results that are comparable to gold-standard segmentations and which are reliable in the analysis of differentiating neuroanatomical abnormalities between healthy controls and pediatric ADHD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to determine the location and relative strength of all transcription-factor binding sites in a genome is important both for a comprehensive understanding of gene regulation and for effective promoter engineering in biotechnological applications. Here we present a bioinformatically driven experimental method to accurately define the DNA-binding sequence specificity of transcription factors. A generalized profile was used as a predictive quantitative model for binding sites, and its parameters were estimated from in vitro-selected ligands using standard hidden Markov model training algorithms. Computer simulations showed that several thousand low- to medium-affinity sequences are required to generate a profile of desired accuracy. To produce data on this scale, we applied high-throughput genomics methods to the biochemical problem addressed here. A method combining systematic evolution of ligands by exponential enrichment (SELEX) and serial analysis of gene expression (SAGE) protocols was coupled to an automated quality-controlled sequence extraction procedure based on Phred quality scores. This allowed the sequencing of a database of more than 10,000 potential DNA ligands for the CTF/NFI transcription factor. The resulting binding-site model defines the sequence specificity of this protein with a high degree of accuracy not achieved earlier and thereby makes it possible to identify previously unknown regulatory sequences in genomic DNA. A covariance analysis of the selected sites revealed non-independent base preferences at different nucleotide positions, providing insight into the binding mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessing bacterial viability by molecular markers might help accelerate the measurement of antibiotic-induced killing. This study investigated whether rRNA could be suitable for this purpose. Cultures of penicillin-susceptible and penicillin-tolerant (Tol1 mutant) Streptococcus gordonii were exposed to mechanistically different penicillin and levofloxacin. Bacterial survival was assessed by viable counts and compared to quantitative real-time PCR amplification of either the 16S rRNA genes or the 16S rRNA, following reverse transcription. Penicillin-susceptible S. gordonii lost > or =4 log(10) CFU/ml of viability over 48 h of penicillin treatment. In comparison, the Tol1 mutant lost < or =1 log(10) CFU/ml. Amplification of a 427-bp fragment of 16S rRNA genes yielded amplicons that increased proportionally to viable counts during bacterial growth but did not decrease during drug-induced killing. In contrast, the same 427-bp fragment amplified from 16S rRNA paralleled both bacterial growth and drug-induced killing. It also differentiated between penicillin-induced killing of the parent and the Tol1 mutant (> or =4 log(10) CFU/ml and < or =1 log(10) CFU/ml, respectively) and detected killing by mechanistically unrelated levofloxacin. Since large fragments of polynucleotides might be degraded faster than smaller fragments, the experiments were repeated by amplifying a 119-bp region internal to the original 427-bp fragment. The amount of 119-bp amplicons increased proportionally to viability during growth but remained stable during drug treatment. Thus, 16S rRNA was a marker of antibiotic-induced killing, but the size of the amplified fragment was critical for differentiation between live and dead bacteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article has been written as a comment to Dr Thomas and Dr Baker's article "Teaching an adult brain new tricks: A critical review of evidence for training-dependent structural plasticity in humans". We deliberately expand on the key question about the biological substrates underlying use-dependent brain plasticity rather than reiterating the authors' main points of criticism already addressed in more general way by previous publications in the field. The focus here is on the following main issues: i) controversial brain plasticity findings in voxel-based morphometry studies are partially due to the strong dependency of the widely used T1-weighted imaging protocol on varying magnetic resonance contrast contributions; ii) novel concepts in statistical analysis allow one to directly infer topological specificity of structural brain changes associated with plasticity. We conclude that iii) voxel-based quantification of relaxometry derived parameter maps could provide a new perspective on use-dependent plasticity by characterisation of brain tissue property changes beyond the estimation of volume and cortical thickness changes. In the relevant sections we respond to the concerns raised by Dr Thomas and Dr Baker from the perspective of the proposed data acquisition and analysis strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Previous studies of the visual outcome in bilateral non-arteritic anterior ischemic optic neuropathy (NAION) have yielded conflicting results, specifically regarding congruity between fellow eyes. Prior studies have used measures of acuity and computerized perimetry but none has compared Goldmann visual field outcomes between fellow eyes. In order to better define the concordance of visual loss in this condition, we reviewed our cases of bilateral sequential NAION, including measures of visual acuity, pupillary function and both pattern and severity of visual field loss.Methods: We performed a retrospective chart review of 102 patients with a diagnosis of bilateral sequential NAION. Of the 102 patients, 86 were included in the study for analysis of final visual outcome between the affected eyes. Visual function was assessed using visual acuity, Goldmann visual fields, color vision and RAPD. A quantitative total visual field score and score per quadrant was analyzed for each eye using the numerical Goldmann visual field scoring method previously described by Esterman and colleagues. Based upon these scores, we calculated the total deviation and pattern deviation between fellow eyes and between eyes of different patients. Statistical significance was determined using nonparametric tests.Results: A statistically significant correlation was found between fellow eyes for multiple parameters, including logMAR visual acuity (P = 0.0101), global visual field (P = 0.0001), superior visual field (P = 0.0001), and inferior visual field (P = 0.0001). In addition, the mean deviation of both total (P = 0.0000000007) and pattern (P = 0.000000004) deviation analyses was significantly less between fellow eyes ("intra"-eyes) than between eyes of different patients ("inter"-eyes).Conclusions: Visual function between fellow eyes showed a fair to moderate correlation that was statistically significant. The pattern of vision loss was also more similar in fellow eyes than between eyes of different patients. These results may help allow better prediction of visual outcome for the second eye in patients with NAION. These findings may also be useful for evaluating efficacy of therapeutic interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate the differences in viscoelastic properties between normal and pathologic Achilles tendons ( AT Achilles tendon s) by using real-time shear-wave elastography ( SWE shear-wave elastography ). Materials and Methods The institutional review board approved this study, and written informed consent was obtained from 25 symptomatic patients and 80 volunteers. One hundred eighty ultrasonographic (US) and SWE shear-wave elastography studies of AT Achilles tendon s without tendonopathy and 30 studies of the middle portion of the AT Achilles tendon in patients with tendonopathy were assessed prospectively. Each study included data sets acquired at B-mode US (tendon morphology and cross-sectional area) and SWE shear-wave elastography (axial and sagittal mean velocity and relative anisotropic coefficient) for two passively mobilized ankle positions. The presence of AT Achilles tendon tears at B-mode US and signal-void areas at SWE shear-wave elastography were noted. Results Significantly lower mean velocity was shown in tendons with tendonopathy than in normal tendons in the relaxed position at axial SWE shear-wave elastography (P < .001) and in the stretched position at sagittal (P < .001) and axial (P = .0026) SWE shear-wave elastography . Tendon softening was a sign of tendonopathy in relaxed AT Achilles tendon s when the mean velocity was less than or equal to 4.06 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 54.2%; 95% confidence interval [ CI confidence interval ]: 32.8, 74.4; specificity, 91.5%; 95% CI confidence interval : 86.3, 95.1) and less than or equal to 5.70 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 41.7%; 95% CI confidence interval : 22.1, 63.3; specificity, 81.8%; 95% CI confidence interval : 75.3, 87.2) and in stretched AT Achilles tendon s, when the mean velocity was less than or equal to 4.86 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 66.7%; 95% CI confidence interval : 44.7, 84.3; specificity, 75.6%; 95% CI confidence interval : 68.5, 81.7) and less than or equal to 14.58 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 58.3%; 95% CI confidence interval : 36.7, 77.9; specificity, 83.5%; 95% CI confidence interval : 77.2, 88.7). Anisotropic results were not significantly different between normal and pathologic AT Achilles tendon s. Six of six (100%) partial-thickness tears appeared as signal-void areas at SWE shear-wave elastography . Conclusion Whether the AT Achilles tendon was relaxed or stretched, SWE shear-wave elastography helped to confirm and quantify pathologic tendon softening in patients with tendonopathy in the midportion of the AT Achilles tendon and did not reveal modifications of viscoelastic anisotropy in the tendon. Tendon softening assessed by using SWE shear-wave elastography appeared to be highly specific, but sensitivity was relatively low. © RSNA, 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Basal ganglia and brain stem nuclei are involved in the pathophysiology of various neurological and neuropsychiatric disorders. Currently available structural T1-weighted (T1w) magnetic resonance images do not provide sufficient contrast for reliable automated segmentation of various subcortical grey matter structures. We use a novel, semi-quantitative magnetization transfer (MT) imaging protocol that overcomes limitations in T1w images, which are mainly due to their sensitivity to the high iron content in subcortical grey matter. We demonstrate improved automated segmentation of putamen, pallidum, pulvinar and substantia nigra using MT images. A comparison with segmentation of high-quality T1w images was performed in 49 healthy subjects. Our results show that MT maps are highly suitable for automated segmentation, and so for multi-subject morphometric studies with a focus on subcortical structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The time course of atherosclerosis burden in distinct vascular territories remains poorly understood. We longitudinally evaluated the natural history of atherosclerotic progression in two different arterial territories using high spatial resolution magnetic resonance imaging (HR-MRI), a powerful, safe, and non-invasive tool. METHODS AND RESULTS: We prospectively studied a cohort of 30 patients (mean age 68.3, n = 9 females) with high Framingham general cardiovascular disease 10-year risk score (29.5%) and standard medical therapy with mild-to-moderate atherosclerosis intra-individually at the level of both carotid and femoral arteries. A total of 178 HR-MRI studies of carotid and femoral arteries performed at baseline and at 1- and 2-year follow-up were evaluated in consensus reading by two experienced readers for lumen area (LA), total vessel area (TVA), vessel wall area (VWA = TVA - LA), and normalized wall area index (NWI = VWA/TVA). At the carotid level, LA decreased (-3.19%/year, P = 0.018), VWA increased (+3.83%/year, P = 0.019), and TVA remained unchanged. At the femoral level, LA remained unchanged, VWA and TVA increased (+5.23%/year and +3.11%/year, both P < 0.01), and NWI increased for both carotid and femoral arteries (+2.28%/year, P = 0.01, and +1.8%/year, P = 0.033). CONCLUSION: The atherosclerotic burden increased significantly in both carotid and femoral arteries. However, carotid plaque progression was associated with negative remodelling, whereas the increase in femoral plaque burden was compensated by positive remodelling. This finding could be related to anatomic and flow differences and/or to the distinct degree of obstruction in the two arterial territories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Remote sensing using airborne imaging spectroscopy (AIS) is known to retrieve fundamental optical properties of ecosystems. However, the value of these properties for predicting plant species distribution remains unclear. Here, we assess whether such data can add value to topographic variables for predicting plant distributions in French and Swiss alpine grasslands. We fitted statistical models with high spectral and spatial resolution reflectance data and tested four optical indices sensitive to leaf chlorophyll content, leaf water content and leaf area index. We found moderate added-value of AIS data for predicting alpine plant species distribution. Contrary to expectations, differences between species distribution models (SDMs) were not linked to their local abundance or phylogenetic/functional similarity. Moreover, spectral signatures of species were found to be partly site-specific. We discuss current limits of AIS-based SDMs, highlighting issues of scale and informational content of AIS data.