990 resultados para PRECISE DETERMINATION
Resumo:
A simple and sensitive method for the determination of short and long-chain fatty acids using high-performance liquid chromatography with fluorimetric detection has been developed. The fatty acids were derivatized to their corresponding esters with 9-(2-hydroxyethyl)-carbazole (HEC) in acetonitrile at 60 degreesC with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride as a coupling agent in the presence of 4-dimethylaminopyridine (DMAP). A mixture of esters of C-1-C-20 fatty acids was completely separated within 38 min in conjunction with a gradient elution on a reversed-phase C-18 column. The maximum fluorescence emission for the derivatized fatty acids is at 365 nm (lambda (ex) 335 nm). Studies on derivatization conditions indicate that fatty acids react proceeded rapidly and smoothly with HEC in the presence of EDC and DMAP in acetonitrile to give the corresponding sensitively fluorescent derivatives. The application of this method to the analysis of long chain fatty acids in plasma is also investigated. The LC separation shows good selectivity and reproducibility for fatty acids derivatives. The R.S.D. (n = 6) for each fatty acid derivative are <4%. The detection limits are at 45-68 fmol levels for C-14-C-20 fatty acids and even lower levels for
Resumo:
This payer presents a concrete theoretical treatment which can be used for transforming the laser-induced fluorescence (LIF) intensity into the population and alignment parameters of a symmetric top molecule, The molecular population and alignment are described by molecular state multipoles. The results are presented in a general excitation-detection geometry and then specialized in some special geometries. The problem how to extract the initial molecular state multipoles from the rotationally resolved LIF intensity is discussed in detail. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
Alcohols were derivatised to their carbazole-9-N-acetic acid (CRA) esters with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC . HCl) as the dehydrating agent. Studies on derivatisation conditions indicated that the coupling reaction proceeded rapidly and smoothly in the presence of a base catalyst in acetonitrile to give the corresponding sensitively fluorescent derivatives. The retention behaviour of alcohol derivatives was investigated by varying mobile phase compositions (ACN-water and MeOH-water). The parameters from the equation log k'=A-BX were evaluated by retention data of derivatives using an isocratic elution with different mobile phases. The results indicated that the parameters derived allowed computation of retention factors in good agreement with experiments. At the same time, a general equation was derived that makes possible predictions of partition coefficient in binary mobile phases with different proportions of organic solvent to water based on some simple regression analysis. The LC separation for the derivatised alcohols containing higher carbon alcohols showed good reproducibility on a reversed-phase C-18 column with gradient elution. The detection limits (excitation at 335 nm, emission at 360 nm) for derivatised alcohols (signal-to-noise ratio=3:1) were in the range of 0.1-0.4 pg per injection. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
A capillary electrophoresis (CE) technique for determining total iron binding capacity (TIBC) of serum has been developed. The optimum serum pretreatment involves the following major steps: at first, saturate serum transferrin with Fe+3; then, dissociate them completely after removing excess unbound Fe. Finally, complex the released iron with phenanthroline, a chromophore, to make suitable for the CE analysis. Ammonium acetate (pH = 5.0) was used as CE background electrolyte solution. In this system, a good linear correlation coefficient was maintained over the range 0.5 similar to 10 mu M (r = 0.9979, n =12). Seven adult serum samples were studied and the TIBC parameters measured. In the present system, 10 similar to 30 mu L serum is sufficient for determination. The study shows that the CE technique described is a powerful method for rapid, efficient, sensitive and reliable analysis and hence particularly suitable for clinical application.
Resumo:
A column method was developed to conveniently and reliably determine the soil organic partition coefficients (K-oc) of three insecticides (methiocarb, azinphos-methyl, fenthion), four fungicides (triadimenol, fuberidazole, tebuconazole, pencycuron), and one herbicide (atrazine), in which real soil acted as a stationary phase and the water solution of pesticide as an eluent. The processes of sorption equilibrium were directly shown through a breakthrough curve(BTC). The log K-oc values are 1.69, 1.95, 2.25, 2.55, 2.69, 2.67, 3.10, and 3.33 for atrazine, triadimenol, methiocarb, fuberidazole, azinphos-methyl, tebuconazole, fenthion and pencycuron, respectively.