993 resultados para PLASMA-LEAD
Resumo:
The drumlin sediments at Chimney Bluffs, New York appear to represent a block-inmatrix style glacial melange. This melange comprises sand stringers, lenses and intraclasts juxtaposed in an apparently massive diamicton. Thin section examination of these glacigenic deposits has revealed microstructures indicative of autokinetic subglacial defonnation which are consistent with a deformable bed origin for the diamicton. These features include banding and. necking of matrix grains, oriented plasma fabrics and the formation of pressure shadows at the long axis ends of elongate clasts. Preservation of primary stratification within the sand intraclasts appears to suggest that these features were pre-existing up-ice deposits that were frozen, entrained, then deposited as part of a defonning till layer beneath an advancing ice sheet. Multi-directional micro-shearing within the sand blocks is thought to reflect the frozen nature of the sand units in such a high strain environment. It is also contended that dewatering of the sediment pile leading to the eventual immobilisation of the defonning till layer was responsible for opening sub-horizontal fissures within the diamicton. These features were subsequently infilled with mass flow poorly sorted sands and silts which were subjected to ductile defonnation during the waning stages of an actively deforming till layer. Microstructures indicative of the dewatering processes in the sand units include patches of fine-grained particles within a coarser-grained matrix and the presence of concentrated zones of translocated clays. However, these units were probably confined within an impermeable diamicton casing that prevented massive pore water influxes from the deforming till layer~ Hence, these microstructures probably reflect localised dewatering of the sand intraclasts. A layered subglacial shear zone model is proposed for the various features exhibited by the drumlin sediments. The complexity of these structures is explained in terms of ii superposing deformation styles in response to changing pore water pressures. Constructional glaciotectonics, as implied by the occurrence of sub-horizontal fissuring, is suggested as the mechanism for the stacking of the sand intraclast units within the diamicton. The usefulness of micromorphology in complimenting the traditional sedimentology of glacigenic deposits is emphasised by the current study. An otherwise massive diamicton was shown to contain microstructures indicative of the very high strain rates expected in a complexly deforming till layer. . It is quite obvious from this investigation that the classification of diamictons needs to be re-examined for evidence of microstructures that could lead to the re-interpretation of diamicton forming processes. RESUME Le pacquet de sediments drumlinaire de Chimney Bluffs, New York, represent un "bloc-en-matrice" genre de melange glaciale. Des structures microscopique comprennent l'evidence pour la defonnation intrinseque attribuee a l'origine lit non resistant du drumlin. PreselVation des structures primaires au coeur des blocs arenaces suggere que ceux sont des depots preexistant qui furent geles, entraines et par la suite sedimentes au milieu d'une couche de debris sous-glaciaires en voie de deformation. Des failles microscopiques a l'interieur des blocs arenaces appuient aussi l'idee d'un bloc cohesif (c'est-a-dire gele) au centre d'un till non resistant. Des implications significatives s'emergent de cette etude pour les conditions sous-glaciaire et les processus de la formation des drumlin.
Resumo:
Nanoporous materials with large surface area and well-ordered pore structure have been synthesized. Thiol groups were grafted on the materials' surface to make heavy metal ion pre-concentration media. The adsorption properties ofthe materials were explored. Mercury, gold and silver can be strongly adsorbed by these materials, even in the presence of alkaline earth metal ion. Though the materials can adsorb other heavy metal ions such as lead and copper, they show differential adsorption ability when several ions are present in solution. The adsorption sequence is: mercury> == silver> copper » lead and cadmium. In the second part of this work, the memory effects of mercury, gold, silver and boron were investigated. The addition of 2% L-cysteine and 1% thiourea eliminates the problems of the three metal ions completely. The wash-out time for mercury dropped from more than 20 minutes to 18 seconds, and the wash-out time for gold decreased from more than 30 minutes to 49 seconds. The memory effect of boron can be reduced by the use of mannitol.
Resumo:
Several inorganic substances (e.g., C£ , Mg , Ca , H ) are potent negative modulators of hemoglobin-oxygen affinity. To evaluate the possibility that potentially adaptive changes in the red cell ionic environment of hemoglobin may take place during acclimation of fishes to increased environmental temperature, hematological status (hemoglobin, hematocrit, red cell numbers, mean erythrocytic volume and hemoglobin content), plasma + + 2+ 2+ and packed red cell electrolyte levels (Na , K , Ca , Mg , C£ ) were evaluated in summer and winter populations of the stenothermal rainbow trout, Salmo gairdneri, following acclimation to 2°, 10°, 18°C, and in a spring population of eurythermal carp, Cyprinus carpio, held at 2°, 16° and 30°C. From these data cell ion concentrations and ion:hemoglobin ratios were estimated. In view of the role of red cell carbonic anhydrase in the reductions of blood C02 tensions and the recruitment of Na and C£~ lost by fishes, a preliminary investigation of thermoacclimatory changes in the activity of this system in rainbow trout erythrocytes was conducted. Few changes in hematological status were encountered following acclimation. There was, however, some evidence of weight-specific differential hematological response in carp. This lead to markedly greater increases in hemoglobin, hematocrit and red cell numbers in smaller rather than in larger specimens at higher temperatures; variations which were 2+ well correlated with changes in plasma Ca . Plasma composition in summer trout was not altered by acclimation. In winter trout plasma Na and K increased at higher temperatures. Carp were characterized by increases in plasma calcium, and reductions in sodium and magnesium under these conditions. Several significant seasonal differences in plasma ion levels were observed in the trout. (n) In trout, only erythrocytic K and K :Hb were altered by acclimation, rising at higher temperatures. In carp Na , Na :Hb, C£~ and C£~:Hb in- 2+ 2+ creased with temperature, while Mg and Mg :Hb declined. Changes in overall ionic composition in carp red cells were consistent with increases in H content. In both species significant reciprocal variations in C£~ 2+ - + and Mg were found. In mammalian systems increases in C£ and H reduce hemoglobin-oxygen affinity by interaction with hemoglobin. Reduction in 2+ 2+ Mg maximizes organophosphate modulator availability by decreasing ATP»Mg complex formation. Thus, the changes observed may be of adaptive value in reducing hemoglobin-oxygen affinity, and facilitating oxygen release to cells at higher temperatures. Trout appear to maintain a high chloridelow magnesium state over the entire thermal tolerance zone. Carp, however, achieved this state only at higher temperatures. In both species mean erythrocytic volume was decreased at higher temperatures and this may facilitate branchial oxygen loading. Since mean erythrocytic volume was inversely related to red cell ion content, it is hypothesized that reductions in cell volume are achieved by export of some unidentified solute or solutes. Variations in the carbonic anhydrase activity that could be attributed to the thermoacclimatory process were quite modest. On the other hand, assays performed at the temperature of acclimation showed a large temperature effect where under in vivo conditions of temperature fish acclimated to higher temperatures might be expected to have higher activities. Furthermore, since hematocrit increased with temperature in these fish, while carbonic anhydrase is present only in the erythrocyte, the whole blood levels of this enzyme are expected to increase and further augment the temperature effect. This, in turn, could aid in the reduction of C02 (111) tension and increase the production of H and HC0~~ used in the active uptake of Na and C£ at higher temperatures.
Resumo:
A simple, low-cost concentric capillary nebulizer (CCN) was developed and evaluated for ICP spectrometry. The CCN could be operated at sample uptake rates of 0.050-1.00 ml min'^ and under oscillating and non-oscillating conditions. Aerosol characteristics for the CCN were studied using a laser Fraunhofter diffraction analyzer. Solvent transport efficiencies and transport rates, detection limits, and short- and long-term stabilities were evaluated for the CCN with a modified cyclonic spray chamber at different sample uptake rates. The Mg II (280.2nm)/l\/lg 1(285.2nm) ratio was used for matrix effect studies. Results were compared to those with conventional nebulizers, a cross-flow nebulizer with a Scott-type spray chamber, a GemCone nebulizer with a cyclonic spray chamber, and a Meinhard TR-30-K3 concentric nebulizer with a cyclonic spray chamber. Transport efficiencies of up to 57% were obtained for the CCN. For the elements tested, short- and long-term precisions and detection limits obtained with the CCN at 0.050-0.500 ml min'^ are similar to, or better than, those obtained on the same instrument using the conventional nebulizers (at 1.0 ml min'^). The depressive and enhancement effects of easily ionizable element Na, sulfuric acid, and dodecylamine surfactant on analyte signals with the CCN are similar to, or better than, those obtained with the conventional nebulizers. However, capillary clog was observed when the sample solution with high dissolved solids was nebulized for more than 40 min. The effects of data acquisition and data processing on detection limits were studied using inductively coupled plasma-atomic emission spectrometry. The study examined the effects of different detection limit approaches, the effects of data integration modes, the effects of regression modes, the effects of the standard concentration range and the number of standards, the effects of sample uptake rate, and the effect of Integration time. All the experiments followed the same protocols. Three detection limit approaches were examined, lUPAC method, the residual standard deviation (RSD), and the signal-to-background ratio and relative standard deviation of the background (SBR-RSDB). The study demonstrated that the different approaches, the integration modes, the regression methods, and the sample uptake rates can have an effect on detection limits. The study also showed that the different approaches give different detection limits and some methods (for example, RSD) are susceptible to the quality of calibration curves. Multicomponents spectral fitting (MSF) gave the best results among these three integration modes, peak height, peak area, and MSF. Weighted least squares method showed the ability to obtain better quality calibration curves. Although an effect of the number of standards on detection limits was not observed, multiple standards are recommended because they provide more reliable calibration curves. An increase of sample uptake rate and integration time could improve detection limits. However, an improvement with increased integration time on detection limits was not observed because the auto integration mode was used.
Resumo:
Landscape geochemical investigations were conducted upon portions of a natural uniform landscape in southern Norway. This consisted of sampling both soil profile samples and spruce tree twigs for the analysis of twelve chemical elements. These elements were cobalt, copper, nickel, lead, zinc, manganese, magnesium, iron, calcium, sodium, potassium and aluminum which were determined by atomic absorption analysis on standardized extraction techniques for both organic and inorganic materials. Two "landscape traverses" were chosen for a comparative study of the effects of varying landscape parameters upon the trace element distribution patterns throughout the landscape traverses. The object of this study was to test this method of investigation and the concept of an ideal uniform landscape under Norwegian conditions. A "control traverse" was established to represent uniform landscape conditions typical of the study area and was used to determine "normal" or average trace element distribution patterns. A "signal traverse" was selected nearby over an area of lead mineralization where the depth to bedrock is very small. The signal traverse provided an area of similar landscape conditions to those of the control traverse with significant differences in the bedrock configuration and composition. This study was also to determine the effect of the bedrock mineralization upon the distribution patterns of the twelve chemical elements within the major components of the two landscape traverses (i.e. soil profiles and tree branches). The lead distribution within the soils of the signal traverse showed localized accumulations of lead within the overburden with maximum values occurring within the organic A horizon of soil profile #10. Above average concentrations of lead were common within the signal traverse, however, the other elements studied were not significantly different from those averages determined throughout the soils of the control traverse. The spruce twig samples did not have corresponding accumulations of lead near the soil lead anomaly. This is attributable to the very localized nature of the lead dispersion pattern within the soils. This approach to the study of the geochemistry of a natural landscape was effective in establishing: a) average or "normal" trace element distribution patterns b) local variations in the landscape morphology and c) the effect of unusually high lead concentrations upon the geochemistry of the landscape (i.e. within the soil profiles and tree branches). This type of study provides the basis for further more intensive studies and serves only as a first approximation of the behaviour of elements within a natural landscape.
Resumo:
Part I: Ultra-trace determination of vanadium in lake sediments: a performance comparison using O2, N20, and NH3 as reaction gases in ICP-DRC-MS Thermal ion-molecule reactions, targeting removal of specific spectroscopic interference problems, have become a powerful tool for method development in quadrupole based inductively coupled plasma mass spectrometry (ICP-MS) applications. A study was conducted to develop an accurate method for the determination of vanadium in lake sediment samples by ICP-MS, coupled with a dynamic reaction cell (DRC), using two differenvchemical resolution strategies: a) direct removal of interfering C10+ and b) vanadium oxidation to VO+. The performance of three reaction gases that are suitable for handling vanadium interference in the dynamic reaction cell was systematically studied and evaluated: ammonia for C10+ removal and oxygen and nitrous oxide for oxidation. Although it was able to produce comparable results for vanadium to those using oxygen and nitrous oxide, NH3 did not completely eliminate a matrix effect, caused by the presence of chloride, and required large scale dilutions (and a concomitant increase in variance) when the sample and/or the digestion medium contained large amounts of chloride. Among the three candidate reaction gases at their optimized Eonditions, creation of VO+ with oxygen gas delivered the best analyte sensitivity and the lowest detection limit (2.7 ng L-1). Vanadium results obtained from fourteen lake sediment samples and a certified reference material (CRM031-040-1), using two different analytelinterference separation strategies, suggested that the vanadium mono-oxidation offers advantageous performance over the conventional method using NH3 for ultra-trace vanadium determination by ICP-DRC-MS and can be readily employed in relevant environmental chemistry applications that deal with ultra-trace contaminants.Part II: Validation of a modified oxidation approach for the quantification of total arsenic and selenium in complex environmental matrices Spectroscopic interference problems of arsenic and selenium in ICP-MS practices were investigated in detail. Preliminary literature review suggested that oxygen could serve as an effective candidate reaction gas for analysis of the two elements in dynamic reaction cell coupled ICP-MS. An accurate method was developed for the determination of As and Se in complex environmental samples, based on a series of modifications on an oxidation approach for As and Se previously reported. Rhodium was used as internal standard in this study to help minimize non-spectral interferences such as instrumental drift. Using an oxygen gas flow slightly higher than 0.5 mL min-I, arsenic is converted to 75 AS160+ ion in an efficient manner whereas a potentially interfering ion, 91Zr+, is completely removed. Instead of using the most abundant Se isotope, 80Se, selenium was determined by a second most abundant isotope, 78Se, in the form of 78Se160. Upon careful selection of oxygen gas flow rate and optimization ofRPq value, previous isobaric threats caused by Zr and Mo were reduced to background levels whereas another potential atomic isobar, 96Ru+, became completely harmless to the new selenium analyte. The new method underwent a strict validation procedure where the recovery of a suitable certified reference material was examined and the obtained sample data were compared with those produced by a credible external laboratory who analyzed the same set of samples using a standardized HG-ICP-AES method. The validation results were satisfactory. The resultant limits of detection for arsenic and selenium were 5 ng L-1 and 60 ng L-1, respectively.
Resumo:
Tesis (Maestría en Ciencias con Especialidad en Microbiología) U.A.N.L.
Resumo:
Tesis (Maestría en Ciencias de la Ingeniería Mecánica con Especialidad en Materiales) UANL, 2011.
Resumo:
Tesis (Maestría en Ciencias con Especialidad en Biología Molecular e Ingeniería Genética) UANL, 2011.
Resumo:
Tesis (Maestría en Ciencias en Nutrición) UANL, 2014.
Resumo:
L'angiotensine-II (Ang-II), synthétisée à partir de sources extracardiaques et intracardiaques, régule l'homéostasie cardiaque en favorisant des effets mitogéniques et en promouvant la croissance cellulaire résultant d’une altération de l'expression génique. Dans cette étude, nous avons évalué la possibilité que les récepteurs de l'angiotensine-1 (AT1) ou les récepteurs de l'angiotensine-2 (AT2) situés sur l'enveloppe nucléaire régulent l’expression génique des cardiomyocytes. En analysant les noyaux cellulaires retenus des fractions de cœur de rat par immunobuvardage Western, nous avons détecté une co-purification préférentielle des protéines AT1 et AT2 avec un marqueur de la membrane nucléaire (Nup 62), par rapport aux marqueurs de la membrane plasmique (Calpactin I), de l’appareil de Golgi (GRP 78) ou du réticulum endoplasmique (GM130). La microscopie confocale a permis de démontrer la présence des AT1 et AT2 dans les membranes nucléaires. La microinjection de l’Ang-II-FITC sur des cardiomyocytes a provoqué une liaison de préférence aux sites nucléaires. Les enregistrements de transients calciques ont illustré que les AT1 nucléaires régulent le relâchement du Ca2+. L’incubation des ligands spécifiques d’AT1 et d’AT2 avec l’UTP [α32P] a résulté en une synthèse de novo d’ARN (par exemple, 16,9 ± 0,5 cpm/ng ADN contrôle vs 162,4 ± 29,7 cpm/ng ADN-Ang II, 219,4 ± 8,2 cpm/ng ADN L -162313 (AT1) et 126,5 ± 8,7 cpm/ng ADN CGP42112A (AT2), P <0,001). L’incubation des noyaux avec Ang-II augmente de façon significative l’expression de NFκB, une réponse qui est réprimée partiellement par la co-administration de valsartan ou de PD123177. Les expériences dose-réponse avec Ang-II administrée à l'ensemble des noyaux purifiés vs. aux cardiomyocytes seuls a montré une augmentation plus importante dans les niveaux d'ARNm de NFκB avec une affinité de ~ 3 fois plus grande (valeurs d’EC50 = 9 contre 28 pmol/L, respectivement), suggérant un rôle préférentiel nucléaire dans la signalisation. Par conséquent, nous avons conclu que les membranes cardiaques nucléaires possèdent des récepteurs d’Ang-II couplés à des voies de signalisation et à la transcription génique. La signalisation nucléaire pourrait jouer un rôle clé dans les changements de l'expression de gènes cardiaques, entraînant ainsi des implications mécanistiques et thérapeutiques diverses.
Resumo:
Le canal calcique de type L, Cav1.2, joue un rôle clé dans le couplage excitation-contraction des myocytes ventriculaires. Il a été montré que la sous-unité Cavα1 était sujette à l’épissage alternatif et que ce phénomène pouvait mener à une protéine tronquée en C-terminal au niveau de l’exon 45 (Liao, Yong et al. 2005). D’autres groupes ont étudié différentes délétions au niveau de l’extrémité C-terminale (De Jongh, Warner et al. 1991; Gao, Cuadra et al. 2001). Les courants mesurés dans la configuration cellule entière, était significativement plus grands que le canal « pleine longueur ». Nous avons décidé de tester certaines de ces délétions (ΔC2030, ΔC1935, ΔC1856, ΔC1733, ΔC1700) en présence ou en absence de la sous-unité auxiliaire Cavβ3, susceptible d’interagir avec l’extrémité C-terminale de la sous-unité Cavα1 par l’intermédiaire de son domaine SH3 (Lao, Kobrinsky et al. 2008). Les résultats obtenus dans les ovocytes de Xénope ont mis en évidence que les sous-unités Cavα1.2 tronquées montraient des courants globaux plus élevés que le canal « pleine longueur » en présence de la sous-unité auxiliaire Cavβ3 et que les sous-unités Cavα1.2 tronquées donnaient des courants en absence de la sous-unité Cavβ3 contrairement à la sous-unité Cavα1.2 « pleine longueur ». Afin de vérifier si l’augmentation des courants macroscopiques était le résultat d’une augmentation du nombre de sous-unités Cavα1.2 à la membrane, nous avons choisi de quantifier la fluorescence spécifiquement due à cette sous-unité en utilisant la méthode de cytométrie de flux (FACS : « Fluorescence Activated Cell Sorting »). L’épitope HA a été inséré dans une région extracellulaire de la sous-unité Cavα1 du canal calcique Cav1.2 et un anticorps anti-HA couplé au FITC (« Fluorescein IsoThioCyanate ») a été utilisé pour observer la fluorescence. Nos résultats confirment que la sous-unité Cavα1-HA du canal calcique Cav1.2, s’exprime à la membrane plasmique en présence de la sous-unité auxiliaire Cavβ3, et qu’en absence de celle-ci, ne s’exprime que peu ou pas à la membrane. Les mêmes résultats ont été obtenus pour les trois délétions testées dans les mêmes conditions soit Cavα1.2-HA ΔC1935, Cavα1.2-HA ΔC1856 et Cavα1.2-HA ΔC1733. Ensemble, ces résultats suggèrent que l’augmentation des courants macroscopiques observés après une délétion partielle du C-terminal n’est pas causée par une augmentation du nombre de protéines Cavα1.2 à la membrane.
Resumo:
La réalisation de dispositifs à des dimensions sous-micrométriques et nanométriques demande une maîtrise parfaite des procédés de fabrication, notamment ceux de gravure. La réalisation des ces dispositifs est complexe et les exigences en termes de qualité et de géométrie des profils de gravure imposent de choisir les conditions opératoires les mieux adaptées. Les simulations de l'évolution spatio-temporelle des profils de gravure que nous proposons dans cette thèse s'inscrivent parfaitement dans ce contexte. Le simulateur que nous avons réalisé offre la possibilité de mieux comprendre les processus qui entrent en jeu lors de la gravure par plasma de profils dans divers matériaux. Il permet de tester l'influence des paramètres du plasma sur la forme du profil et donc de déterminer les conditions opératoires optimales. La mise au point de ce simulateur s'appuie sur les concepts fondamentaux qui gouvernent la gravure par plasma. À partir de l'état des lieux des différentes approches numériques pouvant être utilisées, nous avons élaboré un algorithme stable et adaptable permettant de mettre en évidence l'importance de certains paramètres clés pour la réalisation de profils de gravure par un plasma à haute densité et à basse pression. Les capacités de cet algorithme ont été testées en étudiant d'une part la pulvérisation de Si dans un plasma d'argon et d'autre part, la gravure chimique assistée par les ions de SiO2/Si dans un plasma de chlore. Grâce aux comparaisons entre profils simulés et expérimentaux, nous avons montré l'importance du choix de certains paramètres, comme la nature du gaz utilisé et la pression du plasma, la forme initiale du masque, la sélectivité masque/matériau, le rapport de flux neutre/ion, etc. Nous avons aussi lié ces paramètres à la formation de défauts dans les profils, par exemple celle de facettes sur le masque, de parois concaves, et de micro-tranchées. Enfin, nous avons montré que le phénomène de redépôt des atomes pulvérisés entre en compétition avec la charge électrique de surface pour expliquer la formation de profils en V dans le Pt pulvérisé par un plasma d'argon.
Resumo:
La caractérisation de matériaux par spectroscopie optique d’émission d’un plasma induit par laser (LIPS) suscite un intérêt qui ne va que s’amplifiant, et dont les applications se multiplient. L’objectif de ce mémoire est de vérifier l’influence du choix des raies spectrales sur certaines mesures du plasma, soit la densité électronique et la température d’excitation des atomes neutres et ionisés une fois, ainsi que la température d’ionisation. Nos mesures sont intégrées spatialement et résolues temporellement, ce qui est typique des conditions opératoires du LIPS, et nous avons utilisé pour nos travaux des cibles binaires d’aluminium contenant des éléments à l’état de trace (Al-Fe et Al-Mg). Premièrement, nous avons mesuré la densité électronique à l’aide de l’élargissement Stark de raies de plusieurs espèces (Al II, Fe II, Mg II, Fe I, Mg I, Halpha). Nous avons observé que les densités absolues avaient un comportement temporel différent en fonction de l’espèce. Les raies ioniques donnent des densités électroniques systématiquement plus élevées (jusqu’à 50 % à 200 ns après l’allumage du plasma), et décroissent plus rapidement que les densités issues des raies neutres. Par ailleurs, les densités obtenues par les éléments traces Fe et Mg sont moindres que les densités obtenues par l’observation de la raie communément utilisée Al II à 281,618 nm. Nous avons parallèlement étudié la densité électronique déterminée à l’aide de la raie de l’hydrogène Halpha, et la densité électronique ainsi obtenue a un comportement temporel similaire à celle obtenue par la raie Al II à 281,618 nm. Les deux espèces partagent probablement la même distribution spatiale à l’intérieur du plasma. Finalement, nous avons mesuré la température d’excitation du fer (neutre et ionisé, à l’état de trace dans nos cibles), ainsi que la température d’ionisation, à l’aide de diagrammes de Boltzmann et de Saha-Boltzmann, respectivement. À l’instar de travaux antérieurs (Barthélémy et al., 2005), il nous est apparu que les différentes températures convergeaient vers une température unique (considérant nos incertitudes) après 2-3 microsecondes. Les différentes températures mesurées de 0 à 2 microsecondes ne se recoupent pas, ce qui pourrait s’expliquer soit par un écart à l’équilibre thermodynamique local, soit en considérant un plasma inhomogène où la distribution des éléments dans la plume n’est pas similaire d’un élément à l’autre, les espèces énergétiques se retrouvant au cœur du plasma, plus chaud, alors que les espèces de moindre énergie se retrouvant principalement en périphérie.
Resumo:
La dérégulation du compartiment B est une conséquence importante de l’infection par le virus de l’immunodéficience humaine (VIH), qui peut mener à des manifestations autoimmunes et ultimement à des lymphomes B. Parmi les premières anomalies détectées, on dénote l’activation polyclonale, reflétée par la présence d’hyperglobulinémie (hyper-Ig) et des titres élevés d’autoanticorps chez les patients. On observe également une altération des dynamiques des populations, notamment une expansion de la population des cellules matures activées. De plus, les patients évoluent vers l’incapacité de générer une réponse humorale efficace, et sont sujets à une perte de la mémoire immunologique en phase chronique, caractérisée par une diminution de la population des cellules mémoires et par l’épuisement cellulaire. Toutefois, on connaît très peu les mécanismes impliqués dans de telles altérations. Les cellules dendritiques (DC) sont parmi les premières populations cellulaires à rencontrer et à propager le VIH lors d’une infection, et s’en trouvent affectées directement et indirectement, par le virus et ses composantes. On retrouve en effet une diminution des fréquences de DC dans le sang, les muqueuses et les organes lymphoïdes de patients infectés par le VIH, ainsi qu’un blocage au niveau de la maturation cellulaire. Toutefois, un débat perdure quant à l’apparition de ces altérations durant la phase aigüe de l’infection, et à la restauration des fréquences et des fonctions des DC chez les patients sous traitement. Cette controverse est due à la rareté des études longitudinales incluant des suivis qui s’échelonnent de la phase aigüe à la phase chronique de l’infection. Les DC jouent un rôle important dans le développement, la survie et l’activation des lymphocytes B, de façon T-dépendante et T-indépendante, notamment via des facteurs de croissance tel que BLyS (B lymphocyte stimulator). Par conséquent, nous formulons l’hypothèse que dans le cadre d’une infection VIH, les altérations observées au niveau des cellules B sont modulées par les DC. L’objectif majeur de cette étude est donc d’évaluer l’implication potentielle des DC dans les altérations des cellules B au cours de l’infection par le VIH. Pour ce faire, nous avons d’abord caractérisé de façon longitudinale le statut des populations de DC du sang périphérique de patients infectés au VIH et présentant différents types de progression de la maladie. Cela nous a permis d’évaluer la présence d’une corrélation entre les dynamiques de DC et le type de progression. Par la suite, nous avons évalué la capacité des DC à exprimer BLyS, puis mesuré sa concentration ainsi que celles d’autres facteurs de croissance des cellules B dans le plasma des patients. Enfin, nous avons caractérisé le statut des lymphocytes B, en fonction du stade de l’infection et du taux de progression clinique des patients. Cette étude démontre une diminution de la fréquence des populations de DC myéloïdes (mDC) dans le sang de patients infectés par le VIH sujets à une progression clinique. Cette diminution est observée dès le stade aigu de l’infection et au-delà du traitement antirétroviral (ART). Des concentrations élevées de MCP-1 (monocyte chemotactic protein), MIP (macrophage inflammatory protein) -3α et MIP-3β suggèrent la possibilité d’un drainage vers des sites périphériques. Nous observons également des niveaux supérieurs à la normale de précurseurs CD11c+CD14+CD16- en phase chronique, possiblement liés à une tendence de régénération des DC. Les patients en phase chronique présentent de hautes concentrations plasmatiques de BLyS, reflétée par un haut taux d’expression de cette cytokine par les mDC et leurs précurseurs. Parallèlement, nous observons une expansion des cellules B matures activées ainsi que des taux élevés d’IgG et IgA dans le sang de ces patients. De plus, nous constatons l’expansion d’une population de cellules B qui présente à la fois des caractéristiques de cellules B immatures transitionnelles (TI, transitional immature), et de cellules B recirculantes activées de la zone marginale (MZ, marginal zone), considérées ici comme des «précurseurs/activées de la MZ». Cette étude démontre aussi, chez les progresseurs lents, une meilleure préservation du compartiment des DC du sang périphérique, accompagnée d’une augmentation de précurseurs des DC de phénotype CD11c+CD14+CD16+, ainsi que des concentrations plasmatiques et niveaux d’expression normaux de BLyS. Conséquemment, nous n’avons pas observé d’augmentation des cellules B matures activées et des cellules B précurseurs/activées de la MZ. Toutefois, la fréquence des cellules B matures de la MZ est diminuée, reflétant possiblement leur recrutement vers des sites périphériques et leur contribution à un mécanisme actif de contrôle de la progression de la maladie. L’ensemble de ce travail suggère que dans le cadre d’une infection au VIH, les altérations observées au niveau des DC modulent les anomalies des cellules B. Par conséquent, le maintien de l’équilibre des fonctions DC, notamment les fonctions noninflammatoires, pourrait avoir un impact important dans la prévention de la progression de maladies associées aux altérations du compartiment des cellules B.