989 resultados para PID tuning. PID auto-tuning. Evaluation of control loops. Relay method. PID controllers
Resumo:
Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.
Resumo:
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.
Resumo:
INTRODUCTION: PFAPA syndrome is characterized by periodic fever, associated with pharyngitis, cervical adenitis and/or aphthous stomatitis and belongs to the auto-inflammatory diseases. Diagnostic criteria are based on clinical features and the exclusion of other periodic fever syndromes. An analysis of a large cohort of patients has shown weaknesses for these criteria and there is a lack of international consensus. An International Conference was held in Morges in November 2008 to propose a new set of classification criteria based on a consensus among experts in the field.OBJECTIVE: We aimed to verify the applicability of the new set of classification criteria.PATIENTS & METHODS: 80 patients diagnosed with PFAPA syndrome from 3 centers (Genoa, Lausanne and Geneva) for pediatric rheumatology were included in the study. A detailed description of the clinical and laboratory features was obtained. The new classification criteria and the actual diagnostic criteria were applied to the patients.RESULTS: Only 40/80 patients (50%) fulfilled all criteria of the new classification. 31 patients were excluded because they didn't meet one of the 7 diagnostic criteria, 7 because of 2 criteria, and one because of 3 criteria. When we applied the current criteria to the same patients, 11/80 patients (13.7%) needed to be excluded. 8/80 patients (10%) were excluded from both sets. Exclusion was related only to some of the criteria. Number of patients for each not fulfilled criterion (new set of criteria/actual criteria): age (1/6), symptoms between episodes (2/2), delayed growth (4/1), main symptoms (21/0), periodicity, length of fever, interval between episodes, and length of disease (20/0). The application of some of the new criteria was not easy, as they were both very restrictive and needed precise information from the patients.CONCLUSION: Our work has shown that the new set of classification criteria can be applied to patients suspected for PFAPA syndrome, but it seems to be more restrictive than the actual diagnostic criteria. A further work of validation needs to be done in order to determine if this new set of classification criteria allow a good discrimination between PFAPA patients and other causes of recurrent fever syndromes.
Resumo:
Dengue fever is currently the most important arthropod-borne viral disease in Brazil. Mathematical modeling of disease dynamics is a very useful tool for the evaluation of control measures. To be used in decision-making, however, a mathematical model must be carefully parameterized and validated with epidemiological and entomological data. In this work, we developed a simple dengue model to answer three questions: (i) which parameters are worth pursuing in the field in order to develop a dengue transmission model for Brazilian cities; (ii) how vector density spatial heterogeneity influences control efforts; (iii) with a degree of uncertainty, what is the invasion potential of dengue virus type 4 (DEN-4) in Rio de Janeiro city. Our model consists of an expression for the basic reproductive number (R0) that incorporates vector density spatial heterogeneity. To deal with the uncertainty regarding parameter values, we parameterized the model using a priori probability density functions covering a range of plausible values for each parameter. Using the Latin Hypercube Sampling procedure, values for the parameters were generated. We conclude that, even in the presence of vector spatial heterogeneity, the two most important entomological parameters to be estimated in the field are the mortality rate and the extrinsic incubation period. The spatial heterogeneity of the vector population increases the risk of epidemics and makes the control strategies more complex. At last, we conclude that Rio de Janeiro is at risk of a DEN-4 invasion. Finally, we stress the point that epidemiologists, mathematicians, and entomologists need to interact more to find better approaches to the measuring and interpretation of the transmission dynamics of arthropod-borne diseases.
Resumo:
A decline in human sperm quality and quantity has been reported in numerous Western countries. This observation was also accompanied by an increase in urogenital malformations. The need for epidemiological studies dealing with unbiased populations in order to understand the causes of these observations is obvious. In Switzerland, the large majority of young men are asked to attend a military camp to be drafted into the army. A few weeks before this camp, conscripts were contacted and invited to participate in a large national study on semen quality. The participation was totally voluntary and anonymous. From September 2005 to June 2007, 770 volunteers filled out a questionnaire, underwent a clinical examination and provided sperm, blood and urine samples. Using self-rated health assessments, the observed cohort could be considered as healthy and no testicular cancer was found. Moreover, the testicular volumes, measured using Prader's orchidometry and ultrasonography, were comparable to those already published for young male populations. The median sperm concentration was 47 x 10(6)/ml, which is close to the concentration reported in Denmark, known to have the highest incidence of testicular cancer in Europe. Statistically significant differences were observed between regions with a lower sperm concentration for men residing in the Alps (43 x 10(6)/ml) and in the Zurich area (36 x 10(6)/ml) compared to men from West Plateau (54 x 10(6)/ml) and from the Jura (54 x 10(6)/ml). Such a regional discrepancy could be related to environmental factors, including endocrine disruptors. In order to confirm such regional differences more volunteers from the already studied regions should be studied and other parts of the country should be investigated. The rather low sperm concentration of Swiss young volunteers should be considered as a national health issue and investigated further.
Resumo:
OBJECT: In this study the accuracy of multislice computerized tomography (MSCT) angiography in the postoperative examination of clip-occluded intracranial aneurysms was compared with that of intraarterial digital subtraction (DS) angiography METHODS: Forty-nine consecutive patients with 60 clipped aneurysms (41 of which had ruptured) were studied with the aid of postoperative MSCT and DS angiography. Both types of radiological studies were reviewed independently by two observers to assess the quality of the images, the artifacts left by the clips, the completeness of aneurysm occlusion, the patency of the parent vessel, and the duration and cost of the examination. The quality of MSCT angiography was good in 42 patients (86%). Poor-quality MSCT angiograms (14%) were a result of the late acquisition of images in three patients and the presence of clip or motion artifacts in four. Occlusion of the aneurysm on good-quality MSCT angiograms was confirmed in all but two patients in whom a small (2-mm) remnant was confirmed on DS angiograms. In one patient, occlusion of a parent vessel was seen on DS angiograms but missed on MSCT angiograms. The sensitivity and specificity for detecting neck remnants on MSCT angiography were both 100%, and the sensitivity and specificity for evaluating vessel patency were 80 and 100%, respectively (95% confidence interval 29.2-100%). Interobserver agreements were 0.765 and 0.86, respectively. The mean duration of the examination was 13 minutes for MSCT angiography and 75 minutes for DS angiography (p < 0.05). Multislice CT angiography was highly cost effective (p < 0.01). CONCLUSIONS: Current-generation MSCT angiography is an accurate noninvasive tool used for assessment of clipped aneurysms in the anterior circulation. Its high sensitivity and low cost warrant its use for postoperative routine control examinations following clip placement on an aneurysm. Digital subtraction angiography must be performed if the interpretation of MSCT angiograms is doubtful or if the aneurysm is located in the posterior circulation.
Resumo:
BackgroundResearch indicates that the early attachment patterns of babies could influence their socio-emotional development and prevent the emergence of problematic behaviours in the child later in life. Many studies in the field of early attachment interventions have promoted a secure attachment bond between mother and infant. The purpose of this study was to evaluate the effectiveness of an early pilot intervention programme designed to promote a secure attachment bond in mother-infant dyads belonging to a population seeking regular treatment at urban health centres in Santiago, Chile.MethodsPrimipara mothers were randomly assigned to two intervention conditions: a secure attachment promotion programme (experimental group = 43) or an educational talk (control group = 29). The Strange Situation Assessment was used to collect data on the attachment patterns of babies.ResultsThe results show that after the intervention, there were more babies with secure attachment in the experimental group than in the control group.ConclusionsThese findings represent a preliminary step towards evaluating interventions aimed at promoting secure attachment in Chilean mother-child dyads. While the effect of the intervention is not significant, the effect size obtained is respectable and consistent with other meta-analytic findings.
Resumo:
Attitudinal and behavioural change among gay men in Switzerland was measured between 1987 and 1990 to evaluate the effectiveness of AIDS prevention activities. The methodology used included a self-administered questionnaire published in Swiss gay magazines and distributed by gay organizations (N = 795 in 1987, N = 720 in 1990) and in-depth interviews with men recruited through advertisements and through the questionnaire (N = 42 in 1987, N = 24 in 1990). The two independent sampling procedures yielded similar samples with regard to socio-demographic characteristics, allowing comparisons to be made between the 1987 and 1990 data. Personal confrontation with AIDS (knowing someone who is HIV-positive, or who is ill or dead from AIDS) increased significantly during the period but more adequate ways of coping developed. Behavioural change towards safer sex began well before the first study. The majority of responding homosexuals have adapted their sexual behaviour to the new situation created by AIDS and generally maintain a protective behaviour. However, "exceptions" (condom rupture or episodes of non-protection) are not infrequent and should deserve more attention. Three indicators of sexual behaviour (number of sexual partners, anal sex and use of condom and oral sex with ejaculation), reported for the last 3 months before each study, exhibit few changes between 1987 and 1990: number of partners remained stable, unprotected oral sex decreased. Anal sex slightly increased, the use of condoms remaining stable. Sixty-seven percent of the sample knew their serostatus in 1990 (57% in 1987), and 13% of these stated that they were HIV+ (14% in 1987).
Resumo:
Automotive painting cabins are cleaned with several solvents, being great part of them mixtures of volatile organic compounds (VOCs), where the three xylene isomers are the most important constituents. To evaluate the work-related exposition of the cleaners that use these mixtures of solvents, xylenes have been determined in the working ambient air as well as its metabolite, o-m-p-methyl hippuric acid, has been analysed in urine to establish the dermal and respiratory exposition. This evaluation has been done in order to assess the occupational exposure to VOCs and to know the working conditions of the cleaners, but also to evaluate the effectiveness of personal protective equipment (PPE), the engineering control and the work practices.The xylenes have been chosen as indicators of exposition because they are the main components in the cleaning solvents used, with a level of concentration between 50% and 85%.The Xylenes have an occupational exposure limit (8 h TWA) of 50 ppm (221 mg/m3) and a short-term exposure limit (STEL) of 100 ppm (442 mg/m3). On the other hand, the biological exposure index (BEI) for xylenes is the sum of the total methyl hippuric acids in urine at the end of the work-shift, being the value 1500 mg/g creatinine.
Resumo:
BACKGROUND Recently, different genetic variants located within the IL2/IL21 genetic region as well as within both IL2RA and IL2RB loci have been associated to multiple autoimmune disorders. We aimed to investigate for the first time the potential influence of the IL2/IL21, IL2RA and IL2RB most associated polymorphisms with autoimmunity on the endogenous non-anterior uveitis genetic predisposition. METHODS A total of 196 patients with endogenous non-anterior uveitis and 760 healthy controls, all of them from Caucasian population, were included in the current study. The IL2/IL21 (rs2069762, rs6822844 and rs907715), IL2RA (2104286, rs11594656 and rs12722495) and IL2RB (rs743777) genetic variants were genotyped using TaqMan® allelic discrimination assays. RESULTS A statistically significant difference was found for the rs6822844 (IL2/IL21 region) minor allele frequency in the group of uveitis patients compared with controls (P(-value)=0.02, OR=0.64 CI 95%=0.43-0.94) although the significance was lost after multiple testing correction. Furthermore, no evidence of association with uveitis was detected for the analyzed genetic variants of the IL2RA or IL2RB loci. CONCLUSION Our results indicate that analyzed IL2/IL21, IL2RA and IL2RB polymorphisms do not seem to play a significant role on the non-anterior uveitis genetic predisposition although further studies are needed in order to clear up the influence of these loci on the non-anterior uveitis susceptibility.
Resumo:
Background: We demonstrated that DC Bead (Biocompatibles UK, Ltd) could be loaded with sunitinib and injected intra-arterially in the rabbit without unexpected toxicity. The purpose of this study is to evaluate the antitumoral effect of sunitinib eluting beads in the VX2 tumor model of liver cancer. Methods: VX2 tumors were implanted in the left liver lobe of New-Zealand white rabbits. Animals were assigned to 3 groups: Group 1 (n=6) received 1.5mg of sunitinib loaded in 0.05ml of 100-300um DC Bead, group 2 (n=5) received 0.05ml of 100-300um DC Bead, group 3 (n=5) received 0.05ml NaCl 0.9% in the left hepatic artery. One animal in each group was sacrificed at 24 hours and the others were followed for survival until day 15. Liver enzymes were measured daily. In group 1, plasmatic sunitinib concentration were measured daily by LC MS/MS tandem mass spectroscopy. At day 15 all living animals were sacrificed. After sacrifice, the livers were harvested for determination of the VEGF receptor tyrosine kinase activity by western blot and histopathological examination. Results: In group 1, no animals died during follow-up. In group 2, 2 animals died during follow-up on day x. In control group 3, 3 animals died during follow up on day x. In group 1 plasmatic sunitinib levels remained under therapeutic concentration throughout the experiment. Very high concentrations of sunitinib were measured in the liver tissue 24 and 15 days after embolization. Inhibition of the phosphorylation of the RTK was demonstrated at 24h and 15 days in groups 1. Sunitinib eluting beads seemed to penetrate in the tumor more effectively and there was more necrosis around the beads than their bland counterparts. Conclusions: Administration of sunitinib eluting beads in VX2 carrying rabbits resulted invery high drug concentrations at the site of embolization with minimal systemic passage. Despite the very high tissular sunitinib concentration we did not observe any additional toxicity with loaded beads. Sunitinib eluting beads inhibit the activation of RTK's triggered by ischemia and seem to prolong survival of the treated animals. Therefore we consider that local treatment with sunitinib may provide a promising approach for the treatment of liver cancer.
Resumo:
BACKGROUND The rate of avoidable caesarean sections (CS) could be reduced through multifaceted strategies focusing on the involvement of health professionals and compliance with clinical practice guidelines (CPGs). Quality improvements for CS (QICS) programmes (QICS) based on this approach, have been implemented in Canada and Spain. OBJECTIVES Their objectives are as follows: 1) Toto identify clusters in each setting with similar results in terms of cost-consequences, 2) Toto investigate whether demographic, clinical or context characteristics can distinguish these clusters, and 3) Toto explore the implementation of QICS in the 2 regions, in order to identify factors that have been facilitators in changing practices and reducing the use of obstetric intervention, as well as the challenges faced by hospitals in implementing the recommendations. METHODS Descriptive study with a quantitative and qualitative approach. 1) Cluster analysis at patient level with data from 16 hospitals in Quebec (Canada) (n = 105,348) and 15 hospitals in Andalusia (Spain) (n = 64,760). The outcome measures are CS and costs. For the cost, we will consider the intervention, delivery and complications in mother and baby, from the hospital perspective. Cluster analysis will be used to identify participants with similar patterns of CS and costs based, and t tests will be used to evaluate if the clusters differed in terms of characteristics: Hospital level (academic status of hospital, level of care, supply and demand factors), patient level (mother age, parity, gestational age, previous CS, previous pathology, presentation of the baby, baby birth weight). 2) Analysis of in-depth interviews with obstetricians and midwives in hospitals where the QICS were implemented, to explore the differences in delivery-related practices, and the importance of the different constructs for positive or negative adherence to CPGs. Dimensions: political/management level, hospital level, health professionals, mothers and their birth partner. DISCUSSION This work sets out a new approach for programme evaluation, using different techniques to make it possible to take into account the specific context where the programmes were implemented.
Resumo:
BACKGROUND Based on the mechanism of action, combining somatostatin analogues (SSAs) with mTOR inhibitors or antiangiogenic agents may provide synergistic effects for the treatment of patients with neuroendocrine tumours (NETs). Herein, we investigate the use of these treatment combinations in clinical practice. METHODS This retrospective cross-sectional analysis of patients with NETs treated with the SSA lanreotide and targeted therapies at 35 Spanish hospitals evaluated the efficacy and safety of lanreotide treatment combinations in clinical practice. The data of 159 treatment combinations with lanreotide in 133 patients was retrospectively collected. RESULTS Of the 133 patients, with a median age of 59.4 (16-83) years, 70 (52.6 %) patients were male, 64 (48.1 %) had pancreatic NET, 23 (17.3 %) had ECOG PS ≥2, 41 (30.8 %) had functioning tumours, 63 (47.7 %) underwent surgery of the primary tumour, 45 (33.8 %) had received prior chemotherapy, and 115 (86.5 %) had received prior SSAs. 115 patients received 1 lanreotide treatment combination and 18 patients received between 2 and 5 combinations. Lanreotide was mainly administered in combination with everolimus (73 combinations) or sunitinib (61 combinations). The probability of being progression-free was 78.5 % (6 months), 68.6 % (12 months) and 57.0 % (18 months) for patients who only received everolimus plus lanreotide (n = 57) and 89.3 % (6 months), 73.0 % (12 months), and 67.4 % (18 months) for patients who only received sunitinib and lanreotide (n = 50). In patients who only received everolimus plus lanreotide the median time-to-progression from the initiation of lanreotide combination treatment was 25.8 months (95 % CI, 11.3, 40.3) and it had not yet been reached among the subgroup of patients only receiving sunitinib plus lanreotide. The safety profile of the combination treatment was comparable to that of the targeted agent alone. CONCLUSIONS The combination of lanreotide and targeted therapies, mainly everolimus and sunitinib, is widely used in clinical practice without unexpected toxicities and suggests efficacy that should be explored in randomized prospective clinical trials.
Resumo:
BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.