984 resultados para Mechanical spectroscopy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pond apple usually occurs in swampy areas, but mechanical control may be a viable option in some locations during drier periods. Two machines, the Positrack™ and the Tracksaw™, have been trialled for initial kill rate, amount of follow-up control required, safety to field operators, cost-efficiency and selectivity (effect on native vegetation), compared to other control options. The Positrack™ is a tracked bobcat with a slasher-type attachment that cuts individual trees off near ground level and mulches them. It has no on-board herbicide application capability and requires an additional on-ground operator to apply herbicide by hand. The Tracksaw™ is a tracked mini-excavator with a chainsaw bar and spray applicator on the boom that cuts individual trees off near ground level and applies chemical immediately to the cut stump, requiring only a single operator. Initial trials were done in infestations of similar sizes and densities at the Daintree (Positrack™) and in Innisfail (Tracksaw™) in late 2009. Kill rates to date are 83% for Positrack™ mechanical, 95% for Positrack™ mechanical plus herbicide, and 78% for the Tracksaw™ combined treatment. If ongoing comparison proves either of these machines to be more cost effective, selective, and safer than traditional control methods, mechanical control methods may become more widely used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated inter fragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several molecules like ionophores, vitamins, ion-binding cyclic peptides, acidic phospholipids, surfactants are known to expose the inner side of vesicles, to the externally added cations. Whereas ionophores and certain other systems bring about these changes by a selective transport (influx) of the cation by specialized mechanisms known as the carrier and channel mechanism, other systems cause lysis and vesicle fusion. These systems have been successfully studied using1H,31 P and13C nuclear magnetic resonance spectroscopy after the demonstration, fifteen years ago, of the ability of paramagnetic lanthanide ions to distinguish the inside of the vesicle from the outside. The results of these ’nuclear magnetic resonance kinetics’ experiments are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogen cyanide (HCN) is a toxic chemical that can potentially cause mild to severe reactions in animals when grazing forage sorghum. Developing technologies to monitor the level of HCN in the growing crop would benefit graziers, so that they can move cattle into paddocks with acceptable levels of HCN. In this study, we developed near-infrared spectroscopy (MRS) calibrations to estimate HCN in forage sorghum and hay. The full spectral NIRS range (400-2498 nm) was used as well as specific spectral ranges within the full spectral range, i.e., visible (400-750 nm), shortwave (800-1100 nm) and near-infrared (NIR) (1100-2498 nm). Using the full spectrum approach and partial least-squares (PLS), the calibration produced a coefficient of determination (R-2) = 0.838 and standard error of cross-validation (SECV) = 0.040%, while the validation set had a R-2 = 0.824 with a low standard error of prediction (SEP = 0.047%). When using a multiple linear regression (MLR) approach, the best model (NIR spectra) produced a R-2 = 0.847 and standard error of calibration (SEC) = 0.050% and a R-2 = 0.829 and SEP = 0.057% for the validation set. The MLR models built from these spectral regions all used nine wavelengths. Two specific wavelengths 2034 and 2458 nm were of interest, with the former associated with C=O carbonyl stretch and the latter associated with C-N-C stretching. The most accurate PLS and MLR models produced a ratio of standard error of prediction to standard deviation of 3.4 and 3.0, respectively, suggesting that the calibrations could be used for screening breeding material. The results indicated that it should be feasible to develop calibrations using PLS or MLR models for a number of users, including breeding programs to screen for genotypes with low HCN, as well as graziers to monitor crop status to help with grazing efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Twenty-two diverse sorghum landraces, classified as normal and opaque types obtained from Ethiopia, were characterised for grain quality parameters using near infra-red spectroscopy (NIRS), chemical and Rapid Visco-Analyzer (RVA) characteristics. RESULTS: Protein content ranged from 77 to 182 g kg-1, and starch content from 514 to 745 g kg(-1). The NIRS analysis indicated the pig faecal digestible energy range from 14.6 to 15.7MJ kg(-1) as fed, and the ileal digestible energy range from 11.3 to 13.9MJ kg(-1) as fed. The normal sorghums had higher digestible energy than the opaque sorghums, which exhibited lower RVA viscosities, and higher pasting temperatures and setback ratios. The RVA parameterswere positively correlated with the starch content and negatively correlated with the protein content. The normal and opaque types formed two distinct groups based on principal component and cluster analyses. CONCLUSION: The landraces were different for the various grain quality parameters with some landraces displaying unique RVA and NIRS profiles. This study will guide utilisation of the sorghum landraces in plant improvement programs, and provides a basis for further studies into how starch and other constituents behave in and affect the properties of these landraces. (C) 2011 Society of Chemical Industry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoacoustic spectroscopy has been employed to estimate quantitatively the acid sites on oxide catalysts. The technique involves the measurement of the ratio of intensities of absorption bands due to conjugate bases and acids of indicators adsorbed on the catalyst surface as a function of the amount of added n-butylamine. Basic sites in sodium-impregnated alumina samples have been examined by adsorbing phenolphthalein on these surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoacoustic spectroscopy has been employed to study the electronic spectra of a variety of solids. The systems studied include powders of intensely coloured dyes, amorphous chalcogenides and oxide gels besides polycrystalline samples of several oxide materials. Surface sensitivity of the technique has been examined by study of dye adsorption on oxide surfaces and determination of surface areas of active oxides. Acidic and basic sites on catalyst surfaces have also been estimated by this technique.