992 resultados para MUNSELL 100-HUE TEST


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The amiloride-sensitive epithelial sodium channel (ENaC) constitutes a limiting step in sodium reabsorption across distal airway epithelium and controlling mucociliary clearance. ENaC is activated by serine proteases secreted in the extracellular milieu. In cystic fibrosis lungs, high concentrations of secreted neutrophil elastase (NE) are observed. hNE could activate ENaC and contribute to further decreased mucociliary clearance. The aims of this study were (i) to test the ability of an engineered human neutrophil elastase inhibitor (EPI-hNE4) to specifically inhibit the elastase activation of ENaC-mediated amiloride-sensitive currents (I(Na)) and (ii) to examine the effect of elastase on cell surface expression of ENaC and its cleavage pattern (exogenous proteolysis). Oocytes were exposed to hNE (10-100 microg/ml) and/or trypsin (10 microg/ml) for 2-5 min in the presence or absence of EPI-hNE4 (0.7 microm). hNE activated I(Na) 3.6-fold (p < 0.001) relative to non-treated hENaC-injected oocytes. EPI-hNE4 fully inhibited hNE-activated I(Na) but had no effect on trypsin- or prostasin-activated I(Na). The co-activation of I(Na) by hNE and trypsin was not additive. Biotinylation experiments revealed that cell surface gamma ENaC (but not alpha or beta ENaC) exposed to hNE for 2 min was cleaved (as a 67-kDa fragment) and correlated with increased I(Na). The elastase-induced exogenous proteolysis pattern is distinct from the endogenous proteolysis pattern induced upon preferential assembly, suggesting a causal relationship between gamma ENaC cleavage and ENaC activation, taking place at the plasma membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aromatase inhibitor formestane (4-hydroxy-androst-4-ene-3,17-dione, F) is prohibited in sports by the World Anti-Doping Agency (WADA). F possesses only weak androgenic properties and is presumed to be employed in order to suppress estrogen production during the illicit intake of anabolic steroids by athletes. Former studies additionally showed that F is an endogenous steroid produced in low amounts. According to the regulations of WADA, urinary concentrations above 100 ng/ml are assumed to be due to ingestion of F. To distinguish between endogenous or exogenous sources of urinary F, isotope ratio mass spectrometry (IRMS) is the method of choice. Therefore, a method to determine the carbon isotope ratio (CIR) of F in urine samples was developed and validated. Routine samples (n = 42) showing concentrations of F above 5 ng/ml were investigated and enabled elucidation of the CIR of endogenous F and subsequent the calculation of a reference limit. A reference population encompassing n = 90 males and females was investigated regarding endogenous concentrations of F. An excretion study with one male volunteer was conducted to test and validate the developed method and to identify possible impact of F administration on other endogenous steroids. By CIR determination of F it is clearly possible to elucidate its endogenous or exogenous source. Taking into account the CIR of other target analytes like testosterone, a differentiation between F and androstenedione intake is possible. In 2011, the first exogenous F below the WADA threshold could be detected by means of the developed IRMS method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transfusion-transmitted malaria is rare, but it may produce severe problem in the safety of blood transfusion due to the lack of reliable procedure to evaluate donors potentially exposed to malaria. Here, we evaluated a new enzyme-linked immunosorbent assay malaria antibody test (ELISA malaria antibody test, DiaMed, Switzerland) to detect antibodies to Plasmodium vivax (the indigenous malaria) in the blood samples in the Republic of Korea (ROK). Blood samples of four groups were obtained and analyzed; 100 samples from P.vivax infected patients, 35 from recovery patients, 366 from normal healthy individuals, and 325 from domestic travelers of non-endemic areas residents to risky areas of ROK. P.vivax antibody levels by ELISA were then compared to the results from microscopic examination and polymerase chain reaction (PCR) test. As a result, the ELISA malaria antibody test had a clinical sensitivity of 53.0% and a clinical specificity of 94.0% for P.vivax. Twenty out of 325 domestic travelers (6.2%) were reactive and 28 cases (8.6%) were doubtful. Of the reactive and doubtful cases, only two were confirmed as acute malaria by both microscopy and PCR test. Thus we found that the ELISA malaria antibody test was insufficiently sensitive for blood screening of P.vivax in ROK.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Assess the performance of self-expanding venous cannulas for routine use in open-heart surgery. METHODS: Prospective study in 100 unselected consecutive patients undergoing open-heart surgery with either remote or central smart venous cannulation. RESULTS: The study focuses on the 76 consecutive adult patients (mean age 59.2+/-17.3 years; 60 males, 16 females) undergoing surgical procedures with total cardiopulmonary bypass for either valve procedures (42/76 patients=55.3%), ascending aorta and arch repair (20/76 patients=26.3%), coronary artery revascularization (13/76 patients=17.1%) or other procedures (11/76 patients=14.5%) with 14/76 patients (18.4%) undergoing redo surgery and 6/76 patients (7.9%) undergoing small access surgery. The mean pump flow achieved by gravity drainage alone accounted for 5.0+/-0.6l/min (=114% of target) in the entire study population (n=76) as compared to the calculated, theoretical pump flow of 4.4+/-0.5l/min (p<0.0001). For the femoral cannulation sub-group (n=35) pump flow achieved by gravity drainage alone accounted for 4.9+/-0.6l/min (=114% of target) as compared to the calculated theoretical pump flow of 4.3+/-0.4l/min (p<0.0001). The corresponding numbers for trans-subclavian cannulation (n=7) are 5.2+/-0.5l/min (111%) for the pump flow achieved by gravity drainage as compared to the theoretical target flow of 4.7+/-0.4l/min. For the central cannulation sub-group (n=34) mean flow achieved by gravity drainage with a self-expanding venous cannula accounted for 5.1+/-0.7l/min (=116% of target) as compared to the calculated theoretical flow of 4.4+/-0.6l/min (p<0.0001). CONCLUSION: Full or more than target flow was achieved in 97% of the patients studied undergoing CPB with self-expanding venous cannulas and gravity drainage. Remote venous cannulation with self-expanding cannulas provides similar flows as central cannulation. Augmentation of venous return is no longer necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to test the hypothesis that athletes having a slower oxygen uptake ( VO(2)) kinetics would benefit more, in terms of time spent near VO(2max), from an increase in the intensity of an intermittent running training (IT). After determination of VO(2max), vVO(2max) (i.e. the minimal velocity associated with VO(2max) in an incremental test) and the time to exhaustion sustained at vVO(2max) ( T(lim)), seven well-trained triathletes performed in random order two IT sessions. The two IT comprised 30-s work intervals at either 100% (IT(100%)) or 105% (IT(105%)) of vVO(2max) with 30-s recovery intervals at 50% of vVO(2max) between each repeat. The parameters of the VO(2) kinetics (td(1), tau(1), A(1), td(2), tau(2), A(2), i.e. time delay, time constant and amplitude of the primary phase and slow component, respectively) during the T(lim) test were modelled with two exponential functions. The highest VO(2) reached was significantly lower ( P<0.01) in IT(100%) run at 19.8 (0.9) km(.)h(-1) [66.2 (4.6) ml(.)min(-1.)kg(-1)] than in IT(105%) run at 20.8 (1.0) km(.)h(-1) [71.1 (4.9) ml(.)min(-1.)kg(-1)] or in the incremental test [71.2 (4.2) ml(.)min(-1.)kg(-1)]. The time sustained above 90% of VO(2max) in IT(105%) [338 (149) s] was significantly higher ( P<0.05) than in IT(100%) [168 (131) s]. The average T(lim) was 244 (39) s, tau(1) was 15.8 (5.9) s and td(2) was 96 (13) s. tau(1) was correlated with the difference in time spent above 90% of VO(2max) ( r=0.91; P<0.01) between IT(105%) and IT(100%). In conclusion, athletes with a slower VO(2) kinetics in a vVO(2max) constant-velocity test benefited more from the 5% rise of IT work intensity, exercising for longer above 90% of VO(2max) when the IT intensity was increased from 100 to 105% of vVO(2max).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leprosy in Colombia is in the post-elimination phase; nevertheless, there are regions of this country where the incidence is still around 3-4/100,000. Early detection of leprosy patients is a priority for achieving control and elimination of leprosy; however, the clinical exam is not very sensitive and thus, the majority of patients are diagnosed only when they demonstrate lesions, and damage to the nerves and skin has already occurred. The goal of the present study was to identify Mycobacterium leprae infection and immune responses in household contacts (HHC) of leprosy patients from three prevalent regions of Colombia. Clinical examination, the Mitsuda test, evaluation of IgM anti-PGL-I in the serum, the bacillar index (BI), and polymerase chain reaction (PCR) from nasal swabs (NS) were performed for 402 HHC of 104 leprosy patients during a cross-sectional survey. Positive titers for IgM anti-PGL1 were found for 54 HHC, and PCR-positive NS for 22. The Mitsuda reaction was negative for 38 HHC, although three were positive for IgM anti-PGL-1 titers. The data document that leprosy transmission among HHC is still occurring in a non-endemic country.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of seven limonene β-amino alcohol derivatives has been regioselectively synthesised in moderate to good yields. Two of these compounds were found to be significantly effective against in vitro cultures of the Leishmania (Viannia) braziliensis promastigote form in the micromolar range. The activities found for 3b and 3f were about 100-fold more potent than the standard drug, Pentamidine, in the same test, while limonene did not display any activity. This is the first report of antileishmanial activity by limonene β-amino alcohol derivatives.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical and epidemiological characteristics, adverse events, treatment adherence and effectiveness of isoniazid chemoprophylaxis were analyzed in a cohort of 138 tuberculosis/HIV-coinfected patients. An open, non-randomized, pragmatic prophylactic trial was conducted on adult patients with a normal chest X-ray and positive tuberculin skin test (> 5 mm) who received isoniazid chemoprophylaxis (300 mg/day) for six months. The mean of follow up was 2.8 years (SD 1.3). Adherence to chemoprophylaxis was 87.7% (121/138). Only one patient presented tuberculosis after the end of chemoprophylaxis, corresponding to 0.3 cases per 100 persons per year. The relative risk of some adverse effects was 4.6 times higher (95% CI: 1.9-11.5) in patients with positive anti-HCV serology (4/9, 44.4%) compared to those with negative serology (12/129, 9.6%) (p = 0.002). This study provides evidence regarding the effectiveness and safety of a short and self-administered isoniazid regimen. We recommend the implementation of this routine by health service practitioners.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare two nucleic acid extraction methods for the recovery of enteric viruses from activated sludge. Test samples were inoculated with human adenovirus (AdV), hepatitis A virus (HAV), poliovirus (PV) and rotavirus (RV) and were then processed by an adsorption-elution-precipitation method. Two extraction methods were used: an organic solvent-based method and a silica method. The organic-based method was able to recoup 20% of the AdV, 90% of the RV and 100% of both the PV and HAV from seeded samples. The silica method was able to recoup 1.8% of the AdV and 90% of the RV. These results indicate that the organic-based method is more suitable for detecting viruses in sewage sludge.