993 resultados para MS-line withourt panicle enclosure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

应用基质辅助激光解吸电离飞行时间质谱(MALDI-TOF-MS)技术,研究了E-12、E-31、E-42、E-44和E-51五种牌号环氧树脂。获得了该类树脂的聚合度及其不同聚合度所对应的分子结构;发现了该类树脂中有一定量的环氧氯丙烷的聚合物,并给出了可能的分子结构。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

本文报道了7种新合成的(Z)-1-[2-(三芳基锡)乙烯基]-1-环庚醇有机锡化合物的XPS和MS结果。通过XPS讨论了化合物中不同取代基的存在,对锡内层电子的影响及取代基对Ols结合能化学位移的作用。结果表明,卤素在这里起着重要的作用。通过MS和XPS讨论了不同取代基对O→Sn键的影响。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

采用气相色谱/质谱(GC/MS)联用技术对山东泰山产单叶蔓荆子挥发油的化学成分进行了分析,分离出30多个峰,确认了其中28种成分,占总离子流的95%以上,并对挥发油的主要化学成分Δ3-蒈烯,用气相色谱/傅里叶红外光谱(GC/FTIR)法进行了验证。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

采用对掺入La_2O_3的石墨棒原位活化并结合交换电极回放方法制备了产率较高的金属富勒烯,并用甲苯高温热提取的方法有效地提取出La@C_(2n),其中La@C_(74)为可溶性金属富勒烯增加了新成员.同时,首次采用解吸电子轰击质谱对提取物进行了表征,讨论了提取物的ESR谱.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pure X-ray diffraction profiles have been analysed for polyamide 1010 and PA1O1O-BMI system by means of multipeak fitting resolution of X-ray diffraction. The methods of variance and fourth moment have been applied to determine the particle size and strain values for the paracrystalline materials. The results indicated that both variance and fourth moment of X-ray diffraction line profile yielded approximately the same values of the particle size and the strain. The particle sizes of (100) reflection have been found to decrease with increasing BMI content, whereas the strain values increased.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports some definite evidence for the significance of wavelength positioning accuracy in multicomponent analysis techniques for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). Using scanning spectrometers commercially available today, a large relative error, DELTA(A) may occur in the estimated analyte concentration, owing to wavelength positioning errors, unless a procedure for data processing can eliminate the problem of optical instability. The emphasis is on the effect of the positioning error (deltalambda) in a model scan, which is evaluated theoretically and determined experimentally. A quantitative relation between DELTA(A) and deltalambda, the peak distance, and the effective widths of the analysis and interfering lines is established under the assumption of Gaussian line profiles. The agreement between calculated and experimental DELTA(A) is also illustrated. The DELTA(A) originating from deltalambda is independent of the net analyte/interferent signal ratio; this contrasts with the situation for the positioning error (dlambda) in a sample scan, where DELTA(A) decreases with an increase in the ratio. Compared with dlambda, the effect of deltalambda is generally less significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the evaluation of the relative error (DELTA(A)) in estimated analyte concentrations originating from the wavelength positioning error in a sample scan when multicomponent analysis (MCA) techniques are used for correcting line interferences in inductively coupled plasma atomic emission spectrometry. In the theoretical part, a quantitative relation of DELTA(A) with the extent of line overlap, bandwidth and the magnitude of the positioning error is developed under the assumption of Gaussian line profiles. The measurements of eleven samples covering various typical line interferences showed that the calculated DELTA(A) generally agrees well with the experimental one. An expression of the true detection limit associated with MCA techniques was thus formulated. With MCA techniques, the determination of the analyte and interferent concentrations depend on each other while with conventional correction techniques, such as the three-point method, the estimate of interfering signals is independent of the analyte signals. Therefore. a given positioning error results in a larger DELTA(A) and hence a higher true detection limit in the case of MCA techniques than that in the case of conventional correction methods. although the latter could be a reasonable approximation of the former when the peak distance expressed in the effective width of the interfering line is larger than 0.4. In the light of the effect of wavelength positioning errors, MCA techniques have no advantages over conventional correction methods unless the former can bring an essential reduction ot the positioning error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

本文应用色谱—质谱(GS/MS)及裂解色谱质谱(Py/GC/MS)研究了二甲基乙氧基乙烯基硅烷(VDMES)等离子体聚合的气体冷凝物及聚合物膜。鉴别出多种化合物,并推导了等离子体聚合的反应历程,进而得到了气相反应与表面反应的实验依据。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the results of the crystal and molecular structures, CI-MS and FAB-MS analyse of Cl3GeCH2CH2COOH and Cl3GeCH(CH3)CH2COOH. The characters and active parts of these molecules are also discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[目的]基于气相色谱-质谱(GC-MS)法测定藏木香栽培品种挥发油的化学成分。[方法]采用水蒸气蒸馏法从藏木香栽培品种中提取挥发油,并用GC-MS联用仪对其挥发油的化学成分进行研究。[结果]分离并确认了37种成分,其主要成分是桉叶油二烯5,11(13)-内酯-8,12,异-榄香烯,异-喇叭烯,桉叶油二烯4,11(13)-内酯-8,12。[结论]分析获得的主要化学成分及其功效为藏木香这一天然药用植物资源的人工规范化栽培和进一步综合开发利用提供了科学依据。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

目的:分析治疗胃病常用的藏成药帕朱胶囊(寒水石,诃子,石榴子,胡椒,荜拔等)的主要化学成分。方法:采用超临界CO_2萃取方法提取帕朱胶囊的可溶性成分,并用气相色谱-质谱联用法对提取部位进行化学成分分析,峰面积归一化法计算各组分的相对含量。结果:共分离鉴定了22种化合物,主要成分含量为胡椒碱44.2%、亚油酸21.1%、甲基-甲撑基奥-异丙烯内酯10.5%、棕榈酸4.8%和γ-羟基-榄香烯酸内酯3.5%等。结论:藏药帕朱胶囊的主要化学成分为胡椒碱和亚油酸,两者含量共占全部提取物的65.3%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

目的:用新方法提取藏药材石榴籽油,并对其进行化学成分分析,为石榴籽的药理研究和应用提供实验依据。方法:采用超临界CO_2萃取方法提取石榴籽的可溶性成分,并用气相色谱-质谱联用法对提取部位进行化学成分分析,峰面积归一化法计算各组分的相对含量。结果:共分离鉴定了10种化合物,主要成分含量为亚油酸40.0%、油酸22.7%、棕榈酸17.5%、硬脂酸9.0%及共轭亚油酸5.7%。结论:藏药材石榴籽的主要化学成分为亚油酸和油酸,两者含量共占全部提取物的62.7%。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

蕨麻,藏医谓之卓老沙曾,原植物为蔷薇科委陵菜属鹅绒委陵菜Potentilla anserine L.,为多年生草本.在高海拔地区蕨麻根的中下部形成块根,在温暖低平地区不形成膨大的块根[1].蕨麻全草入药,收敛止血,止咳利痰,治各种出血及下痢.块根入药,有健脾益胃、生津止渴、益气补血功效;治脾虚、腹泻、产后贫血、营养不良等症[2].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

利用荧光衍生试剂1,2-苯并-3,4-二氢咔唑-9-乙基对甲苯磺酸酯(BDETS)作为脂肪酸柱前衍生化试剂,采用梯度洗脱在Eclipse XDB-C_8色谱柱上对游离脂肪酸(FFA)(油酸、亚油酸、软脂酸和硬脂酸)衍生物进行分离.利用柱后在线的串联质谱以大气压化学电离源(APCI)正离子模式实现了各组分的质谱定性.荧光检测的激发和发射波长分别为λ_(ex)=333 nm,λ_(em)=390 nm.脂肪酸的线性回归系数大于0.9990,检出限为3.38~6.59 nmol/L.建立的方法具有良好的重现性.利用此方法对超临界CO_2提取的唐古特白刺籽油中几种游离脂肪酸进行了分析.结果表明白刺籽油中含有大量的游离不饱和脂肪酸.