996 resultados para Longitudinal Imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: MCTI is used to assess acute ischemic stroke (AIS) patients.We postulated that use of MCTI improves patient outcome regardingindependence and mortality.Methods: From the ASTRAL registry, all patients with an AIS and a non-contrast-CT (NCCT), angio-CT (CTA) or perfusion-CT (CTP) within24 h from onset were included. Demographic, clinical, biological, radio-logical, and follow-up caracteristics were collected. Significant predictorsof MCTI use were fitted in a multivariate analysis. Patients undergoingCTA or CTA&CTP were compared with NCCT patients with regards tofavourable outcome (mRS ≤ 2) at 3 months, 12 months mortality, strokemechanism, short-term renal function, use of ancillary diagnostic tests,duration of hospitalization and 12 months stroke recurrence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contralesional brain connectivity plasticity was previously reported after stroke. This study aims at disentangling the biological mechanisms underlying connectivity plasticity in the uninjured motor network after an ischemic lesion. In particular, we measured generalized fractional anisotropy (GFA) and magnetization transfer ratio (MTR) to assess whether poststroke connectivity remodeling depends on axonal and/or myelin changes. Diffusion-spectrum imaging and magnetization transfer MRI at 3T were performed in 10 patients in acute phase, at 1 and 6 months after stroke, which was affecting motor cortical and/or subcortical areas. Ten age- and gender-matched healthy volunteers were scanned 1 month apart for longitudinal comparison. Clinical assessment was also performed in patients prior to magnetic resonance imaging (MRI). In the contralesional hemisphere, average measures and tract-based quantitative analysis of GFA and MTR were performed to assess axonal integrity and myelination along motor connections as well as their variations in time. Mean and tract-based measures of MTR and GFA showed significant changes in a number of contralesional motor connections, confirming both axonal and myelin plasticity in our cohort of patients. Moreover, density-derived features (peak height, standard deviation, and skewness) of GFA and MTR along the tracts showed additional correlation with clinical scores than mean values. These findings reveal the interplay between contralateral myelin and axonal remodeling after stroke.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Current computational neuroanatomy based on MRI focuses on morphological measures of the brain. We present recent methodological developments in quantitative MRI (qMRI) that provide standardized measures of the brain, which go beyond morphology. We show how biophysical modelling of qMRI data can provide quantitative histological measures of brain tissue, leading to the emerging field of in-vivo histology using MRI (hMRI). RECENT FINDINGS: qMRI has greatly improved the sensitivity and specificity of computational neuroanatomy studies. qMRI metrics can also be used as direct indicators of the mechanisms driving observed morphological findings. For hMRI, biophysical models of the MRI signal are being developed to directly access histological information such as cortical myelination, axonal diameters or axonal g-ratio in white matter. Emerging results indicate promising prospects for the combined study of brain microstructure and function. SUMMARY: Non-invasive brain tissue characterization using qMRI or hMRI has significant implications for both research and clinics. Both approaches improve comparability across sites and time points, facilitating multicentre/longitudinal studies and standardized diagnostics. hMRI is expected to shed new light on the relationship between brain microstructure, function and behaviour, both in health and disease, and become an indispensable addition to computational neuroanatomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyzed stability and consistency of coping among adolescents. The objectives were twofold: a) to analyze temporal stability and cross-situational consistency of coping responses after a 17- month interval, taking into account gender, age and type of stressor. b) To analyze the relative weight of contextual versus dispositional factors in predicting future coping. A cohort of 341 adolescents (51% girls and 49% boys aged between 12 and 16) were assessed twice by means of the Coping Responses Inventory - Youth. The results indicated that the coping responses were quite stable over time at the group level, but with important within-subject differences. Girls showed slightly more stability than boys. Among the girls, Avoidance coping showed as much stability as consistency and Approach coping showed more stability than consistency. Among the boys, Avoidance coping showed more stability than consistency, and Approach coping showed both low stability and low consistency. Among the boys, the coping used at Time 1 barely predicted that used at Time 2; in contrast, among the girls, the type of coping used in the past, especially Avoidance coping, predicted the coping that would be used in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 μm. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 ± 5.6 μm in proximal coronary arteries to 13.6 ± 3.3 μm in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: According to the gateway hypothesis, tobacco use is a gateway of cannabis use. However, there is increasing evidence that cannabis use also predicts the progression of tobacco use (reverse gateway hypothesis). Unfortunately, the importance of cannabis use compared to other predictors of tobacco use is less clear. The aim of this study was to examine which variables, in addition to cannabis use, best predict the onset of daily cigarette smoking in young men. METHODS: A total of 5,590 young Swiss men (mean age = 19.4 years, SD = 1.2) provided data on their substance use, socio-demographic background, religion, health, social context, and personality at baseline and after 18 months. We modelled the predictors of progression to daily cigarette smoking using logistic regression analyses (n = 4,230). RESULTS: In the multivariate overall model, use of cannabis remained among the strongest predictors for the onset of daily cigarette use. Daily cigarette use was also predicted by a lifetime use of at least 50 cigarettes, occasional cigarette use, educational level, religious affiliation, parental situation, peers with psychiatric problems, and sociability. CONCLUSIONS: Our results highlight the relevance of cannabis use compared to other potential predictors of the progression of tobacco use and thereby support the reverse gateway hypothesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Imaging in neuroscience, clinical research and pharmaceutical trials often employs the 3D magnetisation-prepared rapid gradient-echo (MPRAGE) sequence to obtain structural T1-weighted images with high spatial resolution of the human brain. Typical research and clinical routine MPRAGE protocols with ~1mm isotropic resolution require data acquisition time in the range of 5-10min and often use only moderate two-fold acceleration factor for parallel imaging. Recent advances in MRI hardware and acquisition methodology promise improved leverage of the MR signal and more benign artefact properties in particular when employing increased acceleration factors in clinical routine and research. In this study, we examined four variants of a four-fold-accelerated MPRAGE protocol (2D-GRAPPA, CAIPIRINHA, CAIPIRINHA elliptical, and segmented MPRAGE) and compared clinical readings, basic image quality metrics (SNR, CNR), and automated brain tissue segmentation for morphological assessments of brain structures. The results were benchmarked against a widely-used two-fold-accelerated 3T ADNI MPRAGE protocol that served as reference in this study. 22 healthy subjects (age=20-44yrs.) were imaged with all MPRAGE variants in a single session. An experienced reader rated all images of clinically useful image quality. CAIPIRINHA MPRAGE scans were perceived on average to be of identical value for reading as the reference ADNI-2 protocol. SNR and CNR measurements exhibited the theoretically expected performance at the four-fold acceleration. The results of this study demonstrate that the four-fold accelerated protocols introduce systematic biases in the segmentation results of some brain structures compared to the reference ADNI-2 protocol. Furthermore, results suggest that the increased noise levels in the accelerated protocols play an important role in introducing these biases, at least under the present study conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Imaging systems have developed latest years and developing is still continuing following years. Manufacturers of imaging systems give promises for the quality of the performance of imaging systems to advertise their products. Promises for the quality of the performance are often so good that they will not be tested in normal usage. The main target in this research is to evaluate the quality of the performance of two imaging systems: Scanner and CCD color camera. Optical measurement procedures were planned to evaluate the quality of imaging performances. Other target in this research is to evaluate calibration programs for the camera and the scanner. Measuring targets had to choose to evaluate the quality of imaging performances. Manufacturers have given definitions for targets. The third task in this research is to evaluate and consider how good measuring targets are.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). METHODS: An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. RESULTS: In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. CONCLUSION: When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been shown in recent ALICE@LHC measurements that the odd flow harmonics, in particular, a directed flow v1, occurred to be weak and dominated by random fluctuations. In this work we propose a new method, which makes the measurements more sensitive to the flow patterns showing global collective symmetries. We demonstrate how the longitudinal center of mass rapidity fluctuations can be identified, and then the collective flow analysis can be performed in the event-by-event center of mass frame. Such a method can be very effective in separating the flow patterns originating from random fluctuations, and the flow patterns originating from the global symmetry of the initial state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The purpose of our study was to assess whether a model combining clinical factors, MR imaging features, and genomics would better predict overall survival of patients with glioblastoma (GBM) than either individual data type. METHODS: The study was conducted leveraging The Cancer Genome Atlas (TCGA) effort supported by the National Institutes of Health. Six neuroradiologists reviewed MRI images from The Cancer Imaging Archive (http://cancerimagingarchive.net) of 102 GBM patients using the VASARI scoring system. The patients' clinical and genetic data were obtained from the TCGA website (http://www.cancergenome.nih.gov/). Patient outcome was measured in terms of overall survival time. The association between different categories of biomarkers and survival was evaluated using Cox analysis. RESULTS: The features that were significantly associated with survival were: (1) clinical factors: chemotherapy; (2) imaging: proportion of tumor contrast enhancement on MRI; and (3) genomics: HRAS copy number variation. The combination of these three biomarkers resulted in an incremental increase in the strength of prediction of survival, with the model that included clinical, imaging, and genetic variables having the highest predictive accuracy (area under the curve 0.679±0.068, Akaike's information criterion 566.7, P<0.001). CONCLUSION: A combination of clinical factors, imaging features, and HRAS copy number variation best predicts survival of patients with GBM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of contrast media in post-mortem radiology differs from clinical approaches in living patients. Post-mortem changes in the vascular system and the absence of blood flow lead to specific problems that have to be considered for the performance of post-mortem angiography. In addition, interpreting the images is challenging due to technique-related and post-mortem artefacts that have to be known and that are specific for each applied technique. Although the idea of injecting contrast media is old, classic methods are not simply transferable to modern radiological techniques in forensic medicine, as they are mostly dedicated to single-organ studies or applicable only shortly after death. With the introduction of modern imaging techniques, such as post-mortem computed tomography (PMCT) and post-mortem magnetic resonance (PMMR), to forensic death investigations, intensive research started to explore their advantages and limitations compared to conventional autopsy. PMCT has already become a routine investigation in several centres, and different techniques have been developed to better visualise the vascular system and organ parenchyma in PMCT. In contrast, the use of PMMR is still limited due to practical issues, and research is now starting in the field of PMMR angiography. This article gives an overview of the problems in post-mortem contrast media application, the various classic and modern techniques, and the issues to consider by using different media.