991 resultados para INTERNAL CAROTID ARTERY
Resumo:
A software for the calculation of unsaturated soil hydraulic conductivity K(theta) is presented for commonly used methods found in the literature, based on field experiments in which a soil profile is submitted to water infiltration followed by internal drainage. The software is available at: dourado@esalq.usp.br.
Resumo:
BACKGROUND: Acute stroke presenting as monoparesis is rare, with a pure motor deficit in the arm or leg extending to an isolated facial paresis. OBJECTIVE: To raise the question if acute stroke presenting as monoparesis is a different entity from stroke with a more extensive motor deficit. PATIENTS: In the Lausanne Stroke Registry (1979-2000), 195 (4.1%) of 4802 patients met the clinical criteria for pure monoparesis involving the face (22%), arm (63%), or leg (15%). RESULTS: In the vast majority of cases (> 95%), monoparesis corresponded to ischemic stroke with a favorable outcome, with initial computed tomography scans or magnetic resonance images showing no signs of hemorrhage. The lesion for a facial deficit was most frequently located subcortically (internal capsule); for an arm deficit, in the superficial middle cerebral artery; and for a leg deficit, in the anterior cerebral artery territory. In pure monoparesis, only 17% of the patients had more than 1 risk factor as compared with 26% of those with bimodal and trimodal hemiparesis and with 46% of all patients with stroke other than those with pure motor stroke. The only frequent risk factor was hypertension (53%); however, this frequency was no different from that in other patients with stroke. No major stroke etiology could be identified in any of the 3 subgroups of monoparesis. CONCLUSION: Our finding of a wide range of stroke localization and etiology in monoparesis without any particular subgroup suggests that no specific plan of investigation can be recommended for these patients.
Resumo:
The case of a man exposed during 25 years to vibration while maneuvering a heavy earth moving tractor is reported. The first clinical manifestation of hand-arm vibration syndrome was a bilateral Raynaud's phenomenon followed five years later by digital necrosis. The arteriography revealed a proximal and bilateral ulnar artery occlusion. Bilateral median nerve conduction abnormalities were also present. Vibration exposure level was much higher than the threshold level proposed by the European Commission. Laboratory examinations for vasculitis and other vascular diseases were all negative. The purpose of this report is to show that vibration can be responsible for proximal occlusion of a medium sized artery and severe neurovascular abnormalities which must be distinguished from the usual vasospastic Raynaud's phenomenon and the classical hypothenar hammer syndrome. An early and correct diagnosis is crucial because continued repetitive trauma can result in irreversible ischemic injury and loss of digits.
Pulmonary-artery pressure and exhaled nitric oxide in Bolivian and Caucasian high altitude dwellers.
Resumo:
There is evidence that high altitude populations may be better protected from hypoxic pulmonary hypertension than low altitude natives, but the underlying mechanism is incompletely understood. In Tibetans, increased pulmonary respiratory NO synthesis attenuates hypoxic pulmonary hypertension. It has been speculated that this mechanism may represent a generalized high altitude adaptation pattern, but direct evidence for this speculation is lacking. We therefore measured systolic pulmonary-artery pressure (Doppler chocardiography) and exhaled nitric oxide (NO) in 34 healthy, middle-aged Bolivian high altitude natives and in 34 age- and sex-matched, well-acclimatized Caucasian low altitude natives living at high altitude (3600 m). The mean+/-SD systolic right ventricular to right atrial pressure gradient (24.3+/-5.9 vs. 24.7+/-4.9 mmHg) and exhaled NO (19.2+/-7.2 vs. 22.5+/-9.5 ppb) were similar in Bolivians and Caucasians. There was no relationship between pulmonary-artery pressure and respiratory NO in the two groups. These findings provide no evidence that Bolivian high altitude natives are better protected from hypoxic pulmonary hypertension than Caucasian low altitude natives and suggest that attenuation of pulmonary hypertension by increased respiratory NO synthesis may not represent a universal adaptation pattern in highaltitude populations.
Resumo:
OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.
Resumo:
Despite two international studies, there is still no consensus concerning prostate cancer screening. The results of a meta-analysis are making us question our convictions concerning pneumococcal vaccination. The preoperative work-up of cataract surgery can be simplified. When describing the efficacy of a treatment to a patient, relative risks are better understood than absolute risks. For rotator cuff syndrome, intramuscular corticosteroid injections are as efficient as intra-articular injections. In patients prescribed clopidogrel, a proton pump inhibitor is not absolutely necessary. The arrival of a anticoagulant that does not need blood monitoring is an interesting option in atrial fibrillation.
Resumo:
Non-invasive visualization of the coronary arteries represents a major challenge in modern cardiology, but this goal may be achieved in the near future by MR angiography. Possible applications are non-invasive diagnosis of coronary artery disease, and follow-up examinations for therapy control after PTCA, in order to detect restenosis at an early stage. A multiple slice technique (2 mm slice thickness, with a spatial resolution of 1 x 1 mm, Philips Gyroscan ACS-II, 1.5 Tesla) was used. Ten volunteers were imaged and 10 patients with coronary artery disease were examined before and after PTCA. MR measurements were validated by quantitative coronary angiography. The diameters of the proximal coronary arteries as measured by both methods were compared, and a good correlation was found (r = 0.76). Thus, it is concluded that non-invasive visualization of the coronary arteries is possible before and after PTCA and allows to determine potential restenoses. However, patient cooperation is essential for good image quality. Moreover, limited spatial image resolution and breathing artifacts restrict MR coronary angiography today to be used as a routine diagnostic tool for the diagnosis of coronary artery disease.
Resumo:
BACKGROUND: Assisted reproductive technology (ART) involves the manipulation of early embryos at a time when they may be particularly vulnerable to external disturbances. Environmental influences during the embryonic and fetal development influence the individual's susceptibility to cardiovascular disease, raising concerns about the potential consequences of ART on the long-term health of the offspring. METHODS AND RESULTS: We assessed systemic (flow-mediated dilation of the brachial artery, pulse-wave velocity, and carotid intima-media thickness) and pulmonary (pulmonary artery pressure at high altitude by Doppler echocardiography) vascular function in 65 healthy children born after ART and 57 control children. Flow-mediated dilation of the brachial artery was 25% smaller in ART than in control children (6.7±1.6% versus 8.6±1.7%; P<0.0001), whereas endothelium-independent vasodilation was similar in the 2 groups. Carotid-femoral pulse-wave velocity was significantly (P<0.001) faster and carotid intima-media thickness was significantly (P<0.0001) greater in children conceived by ART than in control children. The systolic pulmonary artery pressure at high altitude (3450 m) was 30% higher (P<0.001) in ART than in control children. Vascular function was normal in children conceived naturally during hormonal stimulation of ovulation and in siblings of ART children who were conceived naturally. CONCLUSIONS: Healthy children conceived by ART display generalized vascular dysfunction. This problem does not appear to be related to parental factors but to the ART procedure itself. CLINICAL TRIAL REGISTRATION: URL: www.clinicaltrials.gov. Unique identifier: NCT00837642.
Resumo:
Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.