999 resultados para Direct normal irradiances


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of nuclear hormone receptor antagonists that directly inhibit the association of the receptor with its essential coactivators would allow useful manipulation of nuclear hormone receptor signaling. We previously identified 3-(dibutylamino)-1-(4-hexylphenyl)-propan-1-one (DHPPA), an aromatic β-amino ketone that inhibits coactivator recruitment to thyroid hormone receptor β (TRβ), in a high-throughput screen. Initial evidence suggested that the aromatic β-enone 1-(4-hexylphenyl)-prop-2-en-1-one (HPPE), which alkylates a specific cysteine residue on the TRβ surface, is liberated from DHPPA. Nevertheless, aspects of the mechanism and specificity of action of DHPPA remained unclear. Here, we report an x-ray structure of TRβ with the inhibitor HPPE at 2.3-Å resolution. Unreacted HPPE is located at the interface that normally mediates binding between TRβ and its coactivator. Several lines of evidence, including experiments with TRβ mutants and mass spectroscopic analysis, showed that HPPE specifically alkylates cysteine residue 298 of TRβ, which is located near the activation function-2 pocket. We propose that this covalent adduct formation proceeds through a two-step mechanism: 1) β-elimination to form HPPE; and 2) a covalent bond slowly forms between HPPE and TRβ. DHPPA represents a novel class of potent TRβ antagonist, and its crystal structure suggests new ways to design antagonists that target the assembly of nuclear hormone receptor gene-regulatory complexes and block transcription.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis presents the design and implementation of a GPS-signal source suitable for receiver measurements. The developed signal source is based on direct digital synthesis which generates the intermediate frequency. The intermediate frequency is transfered to the final frequency with the aid of an Inphase/Quadrature modulator. The modulating GPS-data was generated with MATLAB. The signal source was duplicated to form a multi channel source. It was shown that, GPS-signals ment for civil navigation are easy to generate in the laboratory. The hardware does not need to be technically advanced if navigation with high level of accuracy is not needed. It was also shown that, the Inphase/Quadrature modulator can function as a single side band upconverter even with a high intermediate frequency. This concept reduces the demands required for output filtering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The use of complementary and alternative medicine (CAM) and complementary and alternative therapies (CAT) during pregnancy is increasing. Scientific evidence for CAM and CAT in the field of obstetrics mainly covers pain relief in labor. Midwives are responsible for labor and delivery care: hence, their knowledge of CAM and CAT is important. The aims of this study are to describe the professional profile of midwives who provide care for natural childbirth in Catalan hospitals accredited as centers for normal birth, to assess midwives" level of training in CAT and their use of these therapies, and to identify specific resources for CAT in labor wards. Methods: A descriptive, cross-sectional, quantitative method was used to assess the level of training and use of CAT by midwives working at 28 hospitals in Catalonia, Spain, accredited as public normal birth centers. Results: Just under a third of midwives (30.4%) trained in CAT after completion of basic training. They trained in an average of 5.97 therapies (SD 3.56). The number of CAT in which the midwives were trained correlated negatively with age (r = - 0.284; p < 0.001) and with their time working at the hospital in years (r = - 0.136; p = 0.036). Midwives trained in CAT considered that the following therapies were useful or very useful for pain relief during labor and delivery: relaxation techniques (64.3%), hydrotherapy (84.8%) and the application of compresses to the perineum (75.9%). The availability of resources for providing CAT during normal birth care varied widely from center to center. Conclusions: Age may influence attitudes towards training. It is important to increase the number of midwives trained in CAM for pain relief during childbirth, in order to promote the use of CAT and ensure efficiency and safety. CAT resources at accredited hospitals providing normal childbirth care should also be standardized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The use of complementary and alternative medicine (CAM) and complementary and alternative therapies (CAT) during pregnancy is increasing. Scientific evidence for CAM and CAT in the field of obstetrics mainly covers pain relief in labor. Midwives are responsible for labor and delivery care: hence, their knowledge of CAM and CAT is important. The aims of this study are to describe the professional profile of midwives who provide care for natural childbirth in Catalan hospitals accredited as centers for normal birth, to assess midwives" level of training in CAT and their use of these therapies, and to identify specific resources for CAT in labor wards. Methods: A descriptive, cross-sectional, quantitative method was used to assess the level of training and use of CAT by midwives working at 28 hospitals in Catalonia, Spain, accredited as public normal birth centers. Results: Just under a third of midwives (30.4%) trained in CAT after completion of basic training. They trained in an average of 5.97 therapies (SD 3.56). The number of CAT in which the midwives were trained correlated negatively with age (r = - 0.284; p < 0.001) and with their time working at the hospital in years (r = - 0.136; p = 0.036). Midwives trained in CAT considered that the following therapies were useful or very useful for pain relief during labor and delivery: relaxation techniques (64.3%), hydrotherapy (84.8%) and the application of compresses to the perineum (75.9%). The availability of resources for providing CAT during normal birth care varied widely from center to center. Conclusions: Age may influence attitudes towards training. It is important to increase the number of midwives trained in CAM for pain relief during childbirth, in order to promote the use of CAT and ensure efficiency and safety. CAT resources at accredited hospitals providing normal childbirth care should also be standardized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM: Our aim was to challenge the validity of these software algorithms. METHODS: We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS: In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION: We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes. Pediatr Pulmonol. 2015; 50:970-977. © 2015 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os transplantes de fígado estão sendo cada vez mais realizados, havendo necessidade, cada vez maior, de uma avaliação acurada das possíveis complicações. A ultra-sonografia é entendida, nesse contexto, como o método de escolha para a avaliação inicial das complicações envolvendo o transplante. Os autores relatam, neste estudo, o achado de coleção líquida adjacente ao ligamento falciforme, no pós-operatório imediato de pacientes transplantados de fígado e que não apresentavam nenhum sinal de complicação infecciosa intra-abdominal. Foi demonstrada a presença de coleção líquida em torno do ligamento falciforme em 33 (94,3%) de 35 pacientes avaliados. Dessa forma, os autores sugerem que este achado pode corresponder a aspecto normal encontrado no pós-operatório imediato de transplante de fígado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The heart relies on continuous energy production and imbalances herein impair cardiac function directly. The tricarboxylic acid (TCA) cycle is the primary means of energy generation in the healthy myocardium, but direct noninvasive quantification of metabolic fluxes is challenging due to the low concentration of most metabolites. Hyperpolarized (13)C magnetic resonance spectroscopy (MRS) provides the opportunity to measure cellular metabolism in real time in vivo. The aim of this work was to noninvasively measure myocardial TCA cycle flux (VTCA) in vivo within a single minute. METHODS AND RESULTS: Hyperpolarized [1-(13)C]acetate was administered at different concentrations in healthy rats. (13)C incorporation into [1-(13)C]acetylcarnitine and the TCA cycle intermediate [5-(13)C]citrate was dynamically detected in vivo with a time resolution of 3s. Different kinetic models were established and evaluated to determine the metabolic fluxes by simultaneously fitting the evolution of the (13)C labeling in acetate, acetylcarnitine, and citrate. VTCA was estimated to be 6.7±1.7μmol·g(-1)·min(-1) (dry weight), and was best estimated with a model using only the labeling in citrate and acetylcarnitine, independent of the precursor. The TCA cycle rate was not linear with the citrate-to-acetate metabolite ratio, and could thus not be quantified using a ratiometric approach. The (13)C signal evolution of citrate, i.e. citrate formation was independent of the amount of injected acetate, while the (13)C signal evolution of acetylcarnitine revealed a dose dependency with the injected acetate. The (13)C labeling of citrate did not correlate to that of acetylcarnitine, leading to the hypothesis that acetylcarnitine formation is not an indication of mitochondrial TCA cycle activity in the heart. CONCLUSIONS: Hyperpolarized [1-(13)C]acetate is a metabolic probe independent of pyruvate dehydrogenase (PDH) activity. It allows the direct estimation of VTCA in vivo, which was shown to be neither dependent on the administered acetate dose nor on the (13)C labeling of acetylcarnitine. Dynamic (13)C MRS coupled to the injection of hyperpolarized [1-(13)C]acetate can enable the measurement of metabolic changes during impaired heart function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dopplervelocimetria colorida é uma modalidade do exame ultra-sonográfico que se expandiu rapidamente em todas as áreas da medicina, em virtude da sua riqueza de informações. A dopplervelocimetria colorida das artérias orbitais tem sido empregada no auxílio diagnóstico de doenças oftalmológicas, bem como para o estudo de doenças específicas como a pré-eclâmpsia. O objetivo deste estudo é descrever a anatomia normal da região orbital e detalhar a técnica de exame dopplervelocimétrico colorido, tendo em vista ser este um exame acessível e reprodutível. Acreditamos que surgirão novas aplicações deste método, que deverá ser inserido na prática diária do radiologista, visando à melhoria da qualidade do diagnóstico e seguimento das doenças oculares e sistêmicas.