981 resultados para Detect


Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: From February-September 2010, seroepidemiological surveys were conducted on non-human primates and transmitter vector capture was used to investigate the possible circulation of arboviruses in the municipalities of Bonito, Campo Grande, and Jardim, State of Mato Grosso do Sul, Brazil. METHODS: A total of 65 primates from the wild and captivity were used, and potential vectors were captured using Castro and dip nets. Serum samples were tested at the Instituto Evandro Chagas, State of Pará, using the hemagglutination inhibition test to detect total antibodies against 19 different arboviruses. Virus isolation was attempted from serum samples and arthropod suspensions using newborn mice and the C6/36 cell line clone. In addition, identification of the vector species was conducted. RESULTS: From the 19 serum samples from Campo Grande, 1 sample had a 1:20 titer for Flavivirus. From the 35 samples collected in Bonito, 17 samples had antibodies to arboviruses, 4 (11.4%) were positive for Alphavirus, and 5 (14.2%) were positive for Flavivirus. Monotypic reactions were observed for the Mayaro (n = 10) and Oropouche (n = 5) viruses, and 6 (17.1%) samples had titers for >1 virus. We captured 120 Culicidae individuals that were potential arbovirus transmitters in Jardim; however, all the samples were negative for the viruses. CONCLUSIONS: Mato Grosso do Sul has a variety of vertebrate hosts and transmission vectors, thereby providing ideal conditions for the emergence or reemergence of arboviruses, including some pathogenic to human beings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The study analyzed positivity of polymerase chain reaction (PCR) on detection of DNA from Leishmania in patients' samples. METHODS: Extracted DNA was submitted to L150/L152, 13Y/13Z, and seminested PCR (snPCR). RESULTS: Results were evidenced by bands of approximately 120, 720, and 670 bp for L150/L152, 13Y/13Z, and snPCR, respectively. L150/L152, 13Y/13Z, and snPCR positivity indexes were 76.9, 56.4, and 9.2 (p>0.05), respectively, for suspected and 93.7, 68.7, and 84.4 (p<0.05), respectively, for confirmed. CONCLUSIONS: Preliminary results showed that these assays, mainly L150/L152 and snPCR, can detect Leishmania DNA and carry potential on laboratory diagnosis of leishmaniasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The precise identification of the genetic variants of the dengue virus is important to understand its dispersion and virulence patterns and to identify the strains responsible for epidemic outbreaks. This study investigated the genetic variants of the capsid-premembrane junction region fragment in the dengue virus serotypes 1 and 2 (DENV1-2). METHODS: Samples from 11 municipalities in the State of Paraná, Brazil, were provided by the Central Laboratory of Paraná. They were isolated from the cell culture line C6/36 (Aedes albopictus) and were positive for indirect immunofluorescence. Ribonucleic acid (RNA) extracted from these samples was submitted to the reverse transcription polymerase chain reaction (RT-PCR) and nested PCR. RESULTS: RT-PCR revealed that 4 of the samples were co-infected with both serotypes. The isolated DENV-1 sequences were 95-100% similar to the sequences of other serotype 1 strains deposited in GenBank. Similarly, the isolated DENV-2 sequences were 98-100% similar to other serotype 2 sequences in GenBank. According to our neighbor-joining tree, all strains obtained in this study belonged to genotype V of DENV-1. The DENV-2 strains, by contrast, belonged to the American/Asian genotypes. CONCLUSIONS: The monitoring of circulating strains is an important tool to detect the migration of virus subtypes involved in dengue epidemics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Introdução: A obstrução da via aérea central (OVAC) refere-se a um processo patológico que conduz a limitação do fluxo de ar ao nível do espaço glótico e subglótico, traqueia e brônquios principais. O seu correcto diagnóstico e tratamento constituem um território de interesse e preocupação para os profissionais de saúde, e requerem um profundo conhecimento da sua etiologia, fisiologia, diagnóstico e opções terapêuticas dado o potencial em originar significativa morbilidade e mortalidade. A avaliação da OVAC abrange múltiplas vertentes, entre as quais se salienta o componente clínico (sinais e sintomas), a repercussão fisiopatológica (função respiratória) e o estudo imagiológico (TC do tórax e broncoscopia). A compilação destes dados associada à etiologia, constituem factores importantes para estabelecer o prognóstico, determinar a necessidade de tratamento ou delinear uma futura intervenção terapêutica. A broncoscopia é o Gold Standard de avaliação desta condição, mas desde há cerca de 40 anos a curva de débito-volume constitui uma ferramenta não invasiva de detecção de OVAC. Apesar deste método ser utilizado até os nossos dias, poucos têm sido os estudos com o objectivo de verificar a sensibilidade e especificidade da curva de débito-volume na detecção de OVAC, bem como averiguar a relação entre as alterações morfológicas e quantitativas da mesma com a localização, o tipo e o grau da obstrução. Material e Métodos: Entre 1 de Novembro de 2009 e 30 de Abril de 2010, os doentes com indicação para a realização de broncoscopia diagnóstica ou terapêutica na Unidade de Técnicas Invasivas Pneumológicas (UTIP) do Centro Hospitalar Lisboa Norte – Hospital Pulido Valente (CHLN – HPV) foram seleccionados de forma consecutiva de acordo com os critérios de inclusão e exclusão. As avaliações (broncoscopia, curva de débito-volume e avaliação da dispneia) realizaram-se com um intervalo de tempo máximo de sete dias. A broncoscopia flexível foi realizada segundo as normas da British Thoracic Society e as curvas de débito-volume segundo as normas da ATS/ERS TaskForce 2005. Para a avaliação da dispneia recorreu-se à escala de dispneia MRC (Medical Research Council). Um painel de peritos realizou a avaliação da morfologia da curva de débito-volume (sugestiva ou não de OVAC) e um elemento independente a verificação dos critérios quantitativos e morfológicos (variáveis intra e extratorácica e fixa) da curva. O estudo foi aprovado pela Comissão de Ética para a Saúde do CHLN e todos os doentes assinaram um consentimento informado de participação. Resultados: Estudaram-se 82 doentes, 36 (44%) dos quais com OVAC. A predominância foi do género masculino, em relação ao feminino. A sensibilidade e especificidade dos critérios quantitativos da curva de débito-volume na detecção de OVAC foi de 91.3% e 88.9% respectivamente. Quando se utilizaram os critérios morfológicos da curva de débito-volume os valores foram de 93.5% e 30.6%. A agregação dos critérios morfológicos e quantitativos permitiu alcançar uma sensibilidade de 95.7% e especificidade de 86.1%. Nesta amostra, o critério quantitativo com maior ocorrência foi o FEF50/FIF50≥1 (83% dos doentes com OVAC). Este mostrou relacionar-se com todas as localizações de obstrução excepto o terço médio da traqueia. Mostrou, ainda, ter uma relação forte e positiva com o grau e tipo de obstrução (intra e extraluminal). O segundo foi o FEV1/PEF≥8, presente em 36% dos casos de OVAC. Relacionou-se com as obstruções no terço inferior da traqueia e brônquio principal direito (BPD). Também apresentou relação forte e positiva com o grau de obstrução e com os tipos de obstrução anteriormente descritos. Quanto à sintomatologia foi possível associar o grau de obstrução com o de dispneia e a presença de estridor com o grau e localização da obstrução na traqueia. Conclusões: Os resultados deste estudo demonstram que os critérios quantitativos da curva de débito-volume têm elevada sensibilidade e especificidade na detecção de OVAC. O critério FEV50/FIF50≥1 tem um bom poder discriminativo na detecção dessa condição, tendo sido relacionado com a localização, o grau e o tipo de obstrução. O critério FEV1/PEF≥8, embora com menor poder discriminativo, também se relaciona com o grau, a localização e o tipo de obstrução. A morfologia da curva tem uma boa sensibilidade mas baixa especificidade na detecção de OVAC, mas a agregação entre os critérios morfológicos e quantitativos aumenta a sensibilidade e especificidade. A dispneia e o estridor foram relacionados com o grau de obstrução e o último com a localização ao nível da traqueia.-------------ABSTRACT: Introduction: Central airway obstruction (CAO) refers to a pathological process that leads to restriction of airflow at the level of the glottis and subglottis, trachea and main bronchi. It’s proper diagnosis and treatment is an area of interest and concern to health professionals, and requires a deep knowledge of its etiology, physiology, diagnosis and treatment options, concerning the potential to cause significant morbidity and mortality. The evaluation of CAO covers multiple aspects: the clinical component (signs and symptoms), the pathophysiological effect (lung function) and the imaging study (bronchoscopy and chest CT). The compilation of this data associated with the etiology, are important for establishing prognosis, determine the need for treatment or outline a future therapeutic intervention. Bronchoscopy is the gold standard for evaluating this condition, but for the last 40 years the flow-volume loop has been used as a noninvasive tool for detecting CAO. Although this method is still in use, only few studies were made in order to verify its sensitivity and specificity in detecting CAO, and investigate the relation between morphological and quantitative changes of the curve to location, type and degree of obstruction. Methods: Between 1st November 2009 and 30th April 2010, patients with indication to perform diagnostic or therapeutic bronchoscopy in Interventional Pulmonology Unit - Hospital Pulido Valente (CHLN - HPV), were selected consecutively according to the inclusion and exclusion criteria. All assessments (bronchoscopy, flow-volume loop and dyspnea) were carried out within a period of seven days. The flexible bronchoscopy was performed according to the standards of the British Thoracic Society and the flow-volume loops in accordance with the standards of the ATS / ERS Taskforce 2005. For the evaluation of dyspnea was used to MRC dyspnea scale (Medical Research Council). A panel of experts evaluated the morphology of flow-volume loop (suggestive or non-suggestive of CAO) and an independent element established the quantitative criteria and morphological (intra and extrathoracic variables and fixed) of the curve. This study was approved by the Ethics Committee for Health CHLN and all the patients signed an informed consent to participate. Results: We’ve studied 82 patients, 36 (44%) of those with CAO. The majority of the patients were males, compared to females. The sensitivity and specificity of the quantitative criteria of the flow-volume curve in detecting CAO was 91.3% and 88.9% respectively. When we used the morphological criteria of flow-volume loop these values were 93.5% and 30.6%. The combination of quantitative and morphological criteria produced values of 95.7% sensitivity and 86.1% specificity. FEF50/FIF50≥1 was the most representative quantitative criterion (83% of patients with CAO) and it was correlated with all sites of obstruction except in the middle third of the trachea. It has shown a strong and positive association with the degree and type of obstruction (intra and extraluminal). The second was the FEV1/PEF ≥ 8, present in 36% of cases of CAO. It could be correlated with the obstruction in the lower third of the trachea and right main bronchus. It also showed a strong positive relation with the degree and types of obstruction described above. Regarding symptoms, we found a link between the degree of obstruction and dyspnea. The presence of stridor was correlated with the location and the degree of obstruction in the trachea. Conclusion: The results of this study demonstrate that the quantitative criteria of the flow-volume loop have a high sensitivity and specificity in detecting CAO. The criterion FEV50/FIF50 ≥ 1 has a good discriminative power to detect this condition and was related to the location, degree and type of obstruction. The criterion FEV1/PEF ≥ 8, although with a weaker discriminative power, also relates to the degree, location and type of obstruction. The morphology of the curve has a good sensitivity but low specificity in detecting CAO although the combination between the morphological and quantitative criteria increases sensitivity and specificity. Dyspnea and stridor were related to the degree of obstruction and the last one with its location in the trachea.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: O presente estudo, enquadra-se, no domínio do exercício profissional dos enfermeiros e na formação em serviço destes profissionais e teve por objectivo avaliar, num grupo de enfermeiros de um serviço de medicina, o impacto de uma intervenção educativa na melhoria dos procedimentos a executar na prática da terapêutica inalatória. A amostra do estudo (amostra por conveniência) foi constituída por oito enfermeiros do serviço de medicina do Hospital Curry Cabral (idades compreendidas entre os 24 a 43 anos de idade), sem anterior formação específica na área da terapêutica inalatória, mas com experiencia profissional prévia com doentes respiratórios. O estudo decorreu em dois momentos de avaliação: avaliação 0 (antes da intervenção educativa) e avaliação 1 (após a intervenção educativa). Entre estes dois momentos, foi ministrada, a todos os enfermeiros, uma acção de formação sobre terapêutica inalatória, com componente teórico-prática. Antes e depois da intervenção educativa foram aplicados dois instrumentos: para avaliação dos conhecimentos teóricos, construi-se e aplicou-se, um questionário de auto-avaliação de conhecimentos sobre terapêutica inalatória ao grupo dos enfermeiros, e para avaliação dos conhecimentos práticos e execução de procedimentos, uma grelha de observação da demonstração da técnica de inalação com três dispositivos inalatórios: MDI, MDI com câmara expansora ACE e DPI turbohaler®. Os resultados do estudo mostraram que o grupo dos enfermeiros da nossa amostra detinha já alguns conhecimentos de carácter teórico, de âmbito geral, sobre a terapêutica inalatória, mas conhecimentos pouco sólidos, nomeadamente no que concerne aos fármacos utilizados por via inalatória. Verificou-se, ainda, um deficiente domínio de conteúdos de carácter mais específico e prático sobre terapêutica inalatória, por exemplo a importância de determinados procedimentos - agitação do inalador, tempo de pausa entre cada inalação, cuidados de manutenção da câmara expansora, higienização da cavidade bucal após a inalação dos corticosteróides. Quanto à observação da técnica de inalação, o grupo dos enfermeiros revelou algumas lacunas, quer relativamente à técnica de inalação com MDI, quer do MDI com câmara expansora, observando-se a execução de passos incorrectos e mesmo omissão de passos por parte dos enfermeiros, antes da intervenção educativa.Não nos foi possível realizar a observação da técnica de inalação com dispositivo de pó seco turbohaler®, dado que nenhum dos enfermeiros da nossa amostra se sentiu capaz de manusear de forma correcta este dispositivo, antes e após a formação. Em termos globais, achamos que a formação dada sobre terapêutica inalatória, mostrou melhorar os conhecimentos teóricos e práticos dos enfermeiros neste âmbito. Esta melhoria ficou claramente demonstrada no aumento do número de respostas correctas dadas pelos enfermeiros no questionário efectuado, após a formação. Do mesmo modo, após a formação, registou-se uma melhoria considerável dos conhecimentos específicos e práticos, no que concerne à importância de determinados procedimentos na prática da terapêutica inalatória - agitação do inalador, tempo de pausa entre cada inalação, cuidados de manutenção da câmara expansora, higienização da cavidade bucal após a inalação dos corticosteróides - observando-se, um maior número de respostas correctas assinaladas no questionário. Em contrapartida, os conhecimentos sobre fármacos administrados por via inalatória, ficaram um pouco aquém das expectativas, pois o número de respostas correctas dadas pelos enfermeiros após a formação não foi significativo. Poderemos mesmo dizer que, a acção de formação com maior grau de especificidade sobre fármacos não se revelou eficaz e gerou até alguma ―confusão‖ neste grupo de enfermeiros, parecendo que os conhecimentos anteriores sobre fármacos por via inalatória não estariam consolidados antes da formação. De igual modo, após a formação, registou-se no grupo dos enfermeiros do estudo uma melhoria na performance da técnica de inalação com o MDI e MDI com a câmara expansora. Os enfermeiros do estudo, não só corrigiram os passos ou itens de avaliação da técnica inalatória, anteriormente executados incorrectamente, mas também, mostraram um melhor conhecimento dos passos ou itens de avaliação da técnica de inalação, com menor número de passos ou itens de avaliação omissos, após a formação. Em contrapartida, a acção de formação, no que diz respeito ao dispositivo de pó seco turbohaler®, não cumpriu o seu objectivo, dado que nenhum dos enfermeiros da amostra foi capaz de demonstrar a técnica de inalação com este dispositivo, antes e após a formação. Poderemos dizer que, não sendo um dispositivo da sua prática clínica, os enfermeiros não sentiram necessidade de adquirir estes conhecimentos. Em síntese, podemos concluir que na sua globalidade, a formação dada (com informação actualizada sobre as orientações mais adequadas neste domínio) e o treino formal dos enfermeiros neste âmbito, foi bastante proveitoso, uma vez que, mostrou melhorar os conhecimentos teóricos e práticos na prática da terapêutica inalatória do grupo de enfermeiros doserviço de medicina. Realça-se, no entanto, a importância de uma formação adequada, sentida como útil pelos enfermeiros, faseada, ligada à prática dos profissionais e alternando com momentos de exercício profissional. Os conhecimentos e os procedimentos dos enfermeiros deverão ainda ser monitorizados e avaliados ao longo do tempo, para a detecção de eventuais desvios que a rotina pode introduzir e para levantamento de novas necessidades de formação.-------------------ABSTRACT: This study fits in the domain of in-service training of professional nurses. It was aimed to assess the impact of an educational intervention and the consequent improvement of the practice of inhalation therapy in a group of nurses from a medical service The study sample (convenience sample) was consituted by eight nurses from the medical service, Hospital Curry Cabral (aged 24-43 years) without previous special training in the field of inhalation therapy, but with prior experience with patients with respiratory diseases. The study ran in two moments of evaluation: evaluation 0 (before the educational intervention) and evaluation 1 (post-intervention). Between these two moments, a training program about therapeutic inhalation was administered to all nurses, with a double component of theory and practice. Before and after the educational intervention two evaluation tools were applied: for the assessment of theoretical knowledge, the nurses had to fill a self-assessment questionnaire and in order to evaluate their knowledge related to procedural skills as well as their performance, they were observed (and their behaviour recorded on a check-list) during a demonstration of three inhalation techniques with devices: metered dose inhaler, metered dose inhaler with a spacer device ACE® and device turbohaler® The study results showed that the group of nurses in our sample had already some knowledge of theoretical nature (general scope of the inhalation therapy) but little solid knowledge, particularly in regard to drugs used in inhalation. In fact, a relatively weaker knowledge was registerd in what concerns specific and practical knowledge about inhalation therapy, for example, the importance of certain procedures - shaking the inhaler, pause between each inhalation, maintenance care of spacer device, mouth cavity hygiene after inhalation of corticosteroids. As for the observation of the inhaler technique, it was found that the group of nurses had a poor inhalation technique, in what concerns inhalation technique with MDI or MDI with spacer device, with a performance with several incorrect steps, or even omission of steps by nurses before the educational intervention. Finally, as the observation technique of the dry powder device turbohaler ®, we were unable to analyze the observation concerning this device, since none of the nurses in our sample, wast able to handlle it correctly, before and after training.In general terms, we found that the training given on inhalation therapy had a positive impact either in the theorical or the pratical knowledge on inhalation therapy (higher number of correct answers after training). Similarly, after training, there was the considerable improvement of specific and practical skills, namely the importance of certain procedures in the practice of inhalation therapy - shaking the inhaler, pause time between each inhalation, maintenance care of spacer device, sanitizing the buccal cavity after inhalation of corticosteroids. In contrast, knowledge about drugs administered by inhalation, were slightly below expectations, showing a lower number of correct answers given by the nurses after training. The training seemed to be a factor of "confusion" for this group of nurses, whose prior knowledge in this domais was not probably very solid to begin with. After training, the group of nurses in the study improved the performance of inhalation technique with MDI and MDI with spacer device. They not only correcty performed the steps or itens for the assessment of inhalation technique, previously performed incorrectly, but also showed a better understanding of the steps or itens for assessing the inhalation technique, with fewer steps missing (after training). In contrast, training with regard to the device turbohaler ® dry powder, was also below expectations, given that none of the nurses in the sample was able to demonstrate inhaler technique with this device before and after training. This was probably due to the fact that, the nurses did not feel the need to acquire this knowledge and the related practice. In summary, we can say that, overall, the training (with updated information on the appropriate policies in this field) showed an improvement in knowledge and performance in the practice of inhalation therapy. It is however crucial to underline the importance of in-service adequate training programmes, perceived as useful by the nurses, developped in different phases, linked to the nurses’ practice and combining with professional practices. The nurses’ knowledge and skills should also be further monitorized and evaluated in order to detect deviations introduced by the rotinization of procedures and to identify new training needs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION:In Venezuela, acute diarrheic syndrome (ADS) is a primary cause of morbi-mortality, often involving the Salmonella genus. Salmonella infections are associated with acute gastroenteritis, one of the most common alimentary intoxications, and caused by the consumption of contaminated water and food, especially meat. METHODS: Conventional and molecular methods were used to detect Salmonella strains from 330 fecal samples from individuals of different ages and both sexes with ADS. Polymerase chain reaction (PCR) was used for the molecular characterization of Salmonella, using invA, sefA, and fliC genes for the identification of this genus and the serotypes Enteritidis and Typhimurium, respectively. RESULTS: The highest frequency of individuals with ADS was found in children 0-2 years old (39.4%), and the overall frequency of positive coprocultures was 76.9%. A total of 14 (4.2%) strains were biochemically and immunologically identified as Salmonella enterica subsp. enterica, of which 7 were classified as belonging to the Enteritidis serotype, 4 to the Typhimurium serotype, and 3 to other serotypes. The S. enterica strains were distributed more frequently in the age groups 3-4 and 9-10 years old. CONCLUSIONS: The molecular characterization method used proved to be highly specific for the typing of S. enterica strains using DNA extracted from both the isolated colonies and selective enrichment broths directly inoculated with fecal samples, thus representing a complementary tool for the detection and identification of ADS-causing bacteria.