998 resultados para Crack detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Après avoir situé le contexte de la recherche et défini les enjeux principaux du travail, différents types de nanoparticules, ainsi que leurs principales caractéristiques, sont parcourues. L'élaboration de critères de sélection ayant permis de déterminer les types de nanoparticules potentiellement adaptés à !a détection de traces papillaires, l'étude s'est alors focalisée sur deux familles de composés: les quantum dots et les nanoparticules d'oxyde de silicium. Deux types de quantum dots ont été synthétisés : le tellurure de cadmium et le sulfure de zinc). Ils n'ont toutefois pas permis la détection de traces papillaires réalistes. En effet, seules des traces fraîches et enrichies en sécrétions ont pu être mises en évidence. Toutefois, des résultats ont été obtenus avec les deux types de quantum dots pour la détection de traces papillaires sanglantes. Après optimisation, les techniques rivalisent avec les méthodes couramment appliquées en routine. Cependant, l'interaction se produisant entre les traces et les nanoparticules n'a pas pu être déterminé. Les nanoparticules d'oxyde de silicium ont dès lors été appliquées dans le but de comprendre plus en détails les interactions avec les traces papillaires. Ces nanoparticules ont l'avantage d'offrir un très bon contrôle de surface, permettant ainsi une étude détaillée des phénomènes en jeu. Des propriétés de surface variables ont dès lors été obtenues en greffant diverses molécules à la surface des nanoparticules d'oxyde de silicium. Après avoir exploré différentes hypothèses d'interaction, il a pu être déterminé qu'une réaction chimique se produit lors qu'un groupement de type carboxyle est présent à la surface des particules. Ce groupement réagit avec les fonctions amines primaires des sécrétions. L'interaction chimique a ensuite pu être renforcée par l'utilisation d'un catalyseur, permettant d'accélérer la réaction. Dans la dernière partie du travail, les nanoparticules d'oxyde de silicium ont été comparées à une technique utilisée en routine, la fumigation de cyanoacrylate. Bien que des études plus approfondies soient nécessaires, il s'avère que l'application de nanoparticules d'oxyde de silicium permet une détection de très bonne qualité, moins dépendante du donneur que les techniques courantes. Ces résultats sont prometteurs en vue du développement d'une technique possédant une sensibilité et une sélectivité accrue. - Having situated the background of research and identified key issues of work, different types of nanoparticles and their main features are reviewed. The development of selection criteria lead to the identification of nanoparticles types potentially suitable for fingermarks detection. The study focused then On two families of compounds: quantum dots and silicon oxide nanoparticles. Two types of quantum dots were synthesized and characterised: cadmium telluride and zinc sulphide. Unfortunally, they did not allow the detection realistic fingermarks. Indeed, only fresh and groomed fingermarks have been detected. However, results have been obtained with both types of quantum dots for the detection of fingermarks in blood. After optimization procedures, the quantum dots based teshniques compete with the methods currently used in routine. However, the interaction occurring between fingermarks and nanoparticles could not be determined. Silicon oxide nanoparticles have therefore been applied in order to understand in detail the interactions With fingermarks. These nanoparticles have the advantage of providing a very good surface control, allowing am in-depth study of the phenomena involved. Versatile surface properties were therefore obtained by grafting various molecules on the surface of silicon oxide nanoparticles. Different hypotheses were investigated and it was determined that a chemical reaction occurred between the surface functionalised nanoparticles and the fingermark residues. The carboxyl groups on the surface of the particles react with primary amines of the secretions. Therefore, this interaction was improved by the use of a catalyst. In the last part of the work, silicon oxide nanoparticles were compared to a routinely used technique: cyanocrylate fuming. Although further studies are still needed, it appears that the application of silicon oxide nanoparticles allows fingermark detection of very good quality, with a lowered donor dependency. These results are promising for the development of techniques with greater sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Our objective is to test the hypothesis that coronary endothelial function (CorEndoFx) does not change with repeated isometric handgrip (IHG) stress in CAD patients or healthy subjects. BACKGROUND: Coronary responses to endothelial-dependent stressors are important measures of vascular risk that can change in response to environmental stimuli or pharmacologic interventions. The evaluation of the effect of an acute intervention on endothelial response is only valid if the measurement does not change significantly in the short term under normal conditions. Using 3.0 Tesla (T) MRI, we non-invasively compared two coronary artery endothelial function measurements separated by a ten minute interval in healthy subjects and patients with coronary artery disease (CAD). METHODS: Twenty healthy adult subjects and 12 CAD patients were studied on a commercial 3.0 T whole-body MR imaging system. Coronary cross-sectional area (CSA), peak diastolic coronary flow velocity (PDFV) and blood-flow were quantified before and during continuous IHG stress, an endothelial-dependent stressor. The IHG exercise with imaging was repeated after a 10 minute recovery period. RESULTS: In healthy adults, coronary artery CSA changes and blood-flow increases did not differ between the first and second stresses (mean % change ±SEM, first vs. second stress CSA: 14.8%±3.3% vs. 17.8%±3.6%, p = 0.24; PDFV: 27.5%±4.9% vs. 24.2%±4.5%, p = 0.54; blood-flow: 44.3%±8.3 vs. 44.8%±8.1, p = 0.84). The coronary vasoreactive responses in the CAD patients also did not differ between the first and second stresses (mean % change ±SEM, first stress vs. second stress: CSA: -6.4%±2.0% vs. -5.0%±2.4%, p = 0.22; PDFV: -4.0%±4.6% vs. -4.2%±5.3%, p = 0.83; blood-flow: -9.7%±5.1% vs. -8.7%±6.3%, p = 0.38). CONCLUSION: MRI measures of CorEndoFx are unchanged during repeated isometric handgrip exercise tests in CAD patients and healthy adults. These findings demonstrate the repeatability of noninvasive 3T MRI assessment of CorEndoFx and support its use in future studies designed to determine the effects of acute interventions on coronary vasoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This clinical study was based on experimental results obtained in nude mice grafted with human colon carcinoma, showing that injected 131I-labeled F(ab')2 and Fab fragments from high affinity anti-carcinoembryonic antigen (CEA) monoclonal antibodies (MAb) gave markedly higher ratios of tumor to normal tissue localization than intact MAb. 31 patients with known colorectal carcinoma, including 10 primary tumors, 13 local tumor recurrences, and 21 metastatic involvements, were injected with 123I-labeled F(ab')2 (n = 14) or Fab (n = 17) fragments from MAb anti-CEA. The patients were examined by emission-computerized tomography (ECT) at 6, 24, and sometimes 48 h after injection using a rotating dual head scintillation camera. All 23 primary tumors and local recurrences except one were clearly visualized on at least two sections of different tomographic planes. Interestingly, nine of these patients had almost normal circulating CEA levels, and three of the visualized tumors weighed only 3-5 g. Among 19 known metastatic tumor involvements, 14 were correctly localized by ECT. Two additional liver and several bone metastases were discovered by immunoscintigraphy. Altogether, 86% of the tumor sites were detected, 82% with F(ab')2 and 89% with Fab fragments. The contrast of the tumor images obtained with Fab fragments suggests that this improved method of immunoscintigraphy has the potential to detect early tumor recurrences and thus to increase the survival of patients. The results of this retrospective study, however, should be confirmed in a prospective study before this method can be recommended for the routine diagnosis of cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vibration-based damage identification (VBDI) techniques have been developed in part to address the problems associated with an aging civil infrastructure. To assess the potential of VBDI as it applies to highway bridges in Iowa, three applications of VBDI techniques were considered in this study: numerical simulation, laboratory structures, and field structures. VBDI techniques were found to be highly capable of locating and quantifying damage in numerical simulations. These same techniques were found to be accurate in locating various types of damage in a laboratory setting with actual structures. Although there is the potential for these techniques to quantify damage in a laboratory setting, the ability of the methods to quantify low-level damage in the laboratory is not robust. When applying these techniques to an actual bridge, it was found that some traditional applications of VBDI methods are capable of describing the global behavior of the structure but are most likely not suited for the identification of typical damage scenarios found in civil infrastructure. Measurement noise, boundary conditions, complications due to substructures and multiple material types, and transducer sensitivity make it very difficult for present VBDI techniques to identify, much less quantify, highly localized damage (such as small cracks and minor changes in thickness). However, while investigating VBDI techniques in the field, it was found that if the frequency-domain response of the structure can be generated from operating traffic load, the structural response can be animated and used to develop a holistic view of the bridge’s response to various automobile loadings. By animating the response of a field bridge, concrete cracking (in the abutment and deck) was correlated with structural motion and problem frequencies (i.e., those that cause significant torsion or tension-compression at beam ends) were identified. Furthermore, a frequency-domain study of operational traffic was used to identify both common and extreme frequencies for a given structure and loading. Common traffic frequencies can be compared to problem frequencies so that cost-effective, preventative solutions (either structural or usage-based) can be developed for a wide range of IDOT bridges. Further work should (1) perfect the process of collecting high-quality operational frequency response data; (2) expand and simplify the process of correlating frequency response animations with damage; and (3) develop efficient, economical, preemptive solutions to common damage types.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Eläinmalliin perustuvien hiehojen odotusarvojen luotettavuus jalostusarvon ennusteena

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a calorimetric assay for the detection of methicillin-resistant Staphylococcus aureus (MRSA) within 5 h. Microbial heat was calculated in culture with and without cefoxitin. Among 30 genetically distinct clinical isolates, 19/20 MRSA (95%) and 10/10 methicillin-susceptible Staphylococcus aureus (100%) were correctly identified. Microcalorimetry may be useful for rapid MRSA screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser systems can be used to detect very weak optical signals. The physical mechanism is the dynamical process of the relaxation of a laser from an unstable state to a steady stable state. We present an analysis of this process based on the study of the nonlinear relaxation time. Our analytical results are compared with numerical integration of the stochastic differential equations that model this process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effective treatment of ovarian cancer depends upon the early detection of the malignancy. Here, we report on the development of a new nanostructured immunosensor for early detection of cancer antigen 125 (CA-125). A gold electrode was modified with mercaptopropionic acid (MPA), and then consecutively conjugated with silica coated gold nanoparticles (AuNP@SiO2), CdSe quantum dots (QDs) and anti-CA-125 monoclonal antibody (mAb). The engineered MPA|AuNP@SiO2|QD|mAb immunosensor was characterised using transmission electron microscopy (TEM), atomic force microscopy (AFM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Successive conjugation of AuNP@SiO2, CdSe QD and anti-CA-125 mAb onto the gold electrode resulted in sensitive detection of CA-125 with a limit of detection (LOD) of 0.0016 U mL(-1) and a linear detection range (LDR) of 0-0.1 U mL(-1). Based on the high sensitivity and specificity of the immunosensor, we propose this highly stable and reproducible biosensor for the early detection of CA-125.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In multiobject pattern recognition the height of the correlation peaks should be controlled when the power spectrum of ajoint transform correlator is binarized. In this paper a method to predetermine the value of detection peaks is demonstrated. The technique is based on a frequency-variant threshold in order to remove the intraclass terms and on a suitable factor to normalize the binary joint power spectrum. Digital simulations and experimental hybrid implementation of this method were carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a method to detect patterns in defocused scenes by means of a joint transform correlator. We describe analytically the correlation plane, and we also introduce an original procedure to recognize the target by postprocessing the correlation plane. The performance of the methodology when the defocused images are corrupted by additive noise is also considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the response and cross sections for the absorption of GW energy generated in a Jordan-Brans-Dicke theory by a resonant mass detector shaped as a hollow sphere. As a source of the GW we take a binary system in the Newtonian approximation. For masses of the stars of the order of the solar mass, the emitted GW sweeps a range of frequencies which include the first resonant mode of the detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treponema pallidum PCR (Tp-PCR) is a direct diagnostic method for primary and secondary syphilis, but there is no recommendation regarding the best choice of target gene. In this study, we sequentially tested 272 specimens from patients with sexually transmitted ulcers using Tp-PCR targeting the tpp47 and then polA genes. The two methods showed similar accuracies and an almost-perfect agreement.