982 resultados para COMPUTED-TOMOGRAPHY ANGIOGRAPHY


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To report a single-center experience treating patients with squamous- cell carcinoma of the anal canal using helical Tomotherapy (HT) and concurrent chemotherapy (CT).Materials/Methods: From October 2007 to February 2011, 55 patients were treated with HT and concurrent CT (5-fluorouracil/capecitabin and mitomycin) for anal squamous-cell carcinoma. All patients underwent computed- tomography-based treatment planning, with pelvic and inguinal nodes receiving 36 Gy in 1.8 Gy/fraction. Following a planned 1-week break, primary tumor site and involved nodes were boosted to a total dose 59.4 Gy in 1.8 Gy/fraction. Dose-volume histograms of several organs at risk (OAR; bladder, small intestine, rectum, femoral heads, penile bulb, external genitalia) were assessed in terms of conformal avoidance. All toxicity was scored according to the CTCAE, v.3.0. HT plans and treatment were implemented using the Tomotherapy, Inc. software and hardware. For dosimetric comparisons, 3D RT and/or IMRT plans were also computed for some of the patients using the CMS planning system, for treatment with 6-18 MV photons and/or electrons with suitable energies from a Siemens Primus linear accelerator equipped with a multileaf collimator.Locoregional control and survival curves were compared with the log-rank test, and multivariate analysis by the Cox model.Results: With 360-degree-of-freedom beam projection, HT has an advantage over other RT techniques (3D or 5-field step-and-shot IMRT). There is significant improvement over 3D or 5-field IMRT plans in terms of dose conformity around the PTV, and dose gradients are steeper outside the target volume, resulting in reduced doses to OARs. Using HT, acute toxicity was acceptable, and seemed to be better than historical standards.Conclusions: Our results suggest that HT combined with concurrent CT for anal cancer is effective and tolerable. Compared to 3D RT or 5-field step-andshot IMRT, there is better conformity around the PTV, and better OAR sparing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nationwide surveys on radiation dose to the population from medical radiology are recommended in order to follow the trends in population exposure and ensure radiation protection. The last survey in Switzerland was conducted in 1998, and the annual effective dose from medical radiology was estimated to be 1 mSv y(-1) per capita. The purpose of this work was to follow the trends in diagnostic radiology between 1998 and 2008 in Switzerland and determine the contribution of different modalities and types of examinations to the collective effective dose from medical x-rays. For this reason, an online database (www.raddose.ch) was developed. All healthcare providers who hold a license to run an x-ray unit in the country were invited to participate in the survey. More than 225 examinations, covering eight radiological modalities, were included in the survey. The average effective dose for each examination was reassessed. Data from about 3,500 users were collected (42% response rate). The survey showed that the annual effective dose was 1.2 mSv/capita in 2008. The most frequent examinations are conventional and dental radiographies (88%). The contribution of computed tomography was only 6% in terms of examination frequency but 68% in terms of effective dose. The comparison with other countries showed that the effective dose per capita in Switzerland was in the same range as in other countries with similar healthcare systems, although the annual number of examinations performed in Switzerland was higher.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the combination of ultrasound (US) + fine-needle aspiration (FNA) in the assessment of salivary gland tumours in the hands of the otolaryngologist. DESIGN: A retrospective review of case notes was performed. SETTING: Two university teaching hospitals in Switzerland. PARTICIPANTS: One hundred and three patients with a total of 106 focal masses of the salivary glands were included. Clinician-operated US + FNA were the first line of investigation for these lesions. All patients underwent surgical excision of the lesion, which allowed for confirmation of diagnosis by histopathology in 104 lesions and by laboratory testing in two lesions. MAIN OUTCOME MEASURES: Primary--diagnostic accuracy in identifying true salivary gland neoplasms and detecting malignancy. Secondary--predicting an approximate and specific diagnosis in these tumours. RESULTS: The combination of US + FNA achieved a diagnostic accuracy of 99% in identifying and differentiating true salivary gland neoplasms from tumour-like lesions. In detecting malignancy, this combination permitted an accuracy of 98%. An approximate diagnosis was possible in 89%, and a specific diagnosis in 69% of our patients. CONCLUSIONS: Due to economic factors and a high diagnostic accuracy, the combination of US + FNA represents the investigation method of choice for most salivary gland tumours. We suggest that the otolaryngologist be employed in carrying out these procedures, as is already the rule in other medical specialties, while computed tomography and magnetic resonance imaging should be reserved to those few lesions, which cannot be delineated completely by sonography.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to important alteration caused by long time decomposition, the gases in human bodies buried for more than a year have not been investigated. For the first time, the results of gas analysis sampled from bodies recently exhumed after 30 years are presented. Adipocere formation has prevented the bodies from too important alteration, and gaseous areas were identified. The sampling was performed with airtight syringes assisted by multi-detector computed tomography (MDCT) in those specific areas. The important amount of methane (CH4), coupled to weak amounts of hydrogen (H2) and carbon dioxide (CO2), usual gaseous alteration indicators, have permitted to confirm methanogenesis mechanism for long period of alteration. H2 and CO2 produced during the first stages of the alteration process were consumed through anaerobic oxidation by methanogenic bacteria, generating CH4.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present study was carried out to check whether classic osteometric parameters can be determined from the 3D reconstructions of MSCT (multislice computed tomography) scans acquired in the context of the Virtopsy project. To this end, four isolated and macerated skulls were examined by six examiners. First the skulls were conventionally (manually) measured using 32 internationally accepted linear measurements. Then the skulls were scanned by the use of MSCT with slice thicknesses of 1.25 mm and 0.63 mm, and the 33 measurements were virtually determined on the digital 3D reconstructions of the skulls. The results of the traditional and the digital measurements were compared for each examiner to figure out variations. Furthermore, several parameters were measured on the cranium and postcranium during an autopsy and compared to the values that had been measured on a 3D reconstruction from a previously acquired postmortem MSCT scan. The results indicate that equivalent osteometric values can be obtained from digital 3D reconstructions from MSCT scans using a slice thickness of 1.25 mm, and from conventional manual examinations. The measurements taken from a corpse during an autopsy could also be validated with the methods used for the digital 3D reconstructions in the context of the Virtopsy project. Future aims are the assessment and biostatistical evaluation in respect to sex, age and stature of all data sets stored in the Virtopsy project so far, as well as of future data sets. Furthermore, a definition of new parameters, only measurable with the aid of MSCT data would be conceivable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDI(vol)) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDI(vol): 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.