980 resultados para COEFFICIENT


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The murine model of chronic Chaga's myocardiopathy was developed in 201 inbred and outbred mice. The experimental groups consisted of 1st: 73 inbred AKR and A/J mice inoculated with one of the following. Trypanosoma cruzi strains: Peruvian (Type I), 12 SF (Type II) or Colombian (Type III); 2nd: 128 outbred Swiss mice, chronically infected either with Type II or Type III strains isolated from human patients from different geographical areas. All T. cruzi strains were previoulsly characterized by their morphobiological behaviour in mice and by isoenzymatic patterns. For the 1st group the inoculum was 5 x 10**4 for the Peruvian strain and 1 x 10**5 for the 12 SF and Colombian strains. In the 2nd group-Swiss mice the inoculum size varied from 2 x 10**4 to 2 x 10**5. The inbred animals were killed at a 3 time-point scale (90, 180 and 240 days) post-infection. The Swiss mice were killed from 180 to 660 days after infection. The evaluation of parasitemia and serology (xeodiagnosis and indirect immunofluorescent test) was performed. The incidence of macroscopic alterations of the heart and cardiac index were evaluated. Histopathological lesions of the myocardium were graded. The influence of T. cruzi strain on the intensity of cardiac lesions was evaluated by the Chi-square test; the incidence of inflammatory lesions and its relationship to the parasite strain was evaluated by the Fisher test. The influence of the duration of infection was evaluated by using the Gamma Coefficient of Kruskal and Goodman and its measure of significance. Slight to severe microscopic alterations occurred in 85% of the chronically infected nice. There were a clear predominance on the incidence and intensity of inflammatory and fibrotic alterations for the mice infected with Type III strains. Statistical analysis has shown significant differences among the infected groups, in the inflammatory and fibrotic lesions. Macroscopic alterations (right cavities dilatation and apex aneurism of left ventricle), differed in incidence according to mice strains; in Swiss and AKR mice, significant differences were seen in mice infected with different T. cruzi strains, but the A/J mice failed to show significant differences correlated with different parasite strains. The duration of infection, from 90 to 240 days, could not be correlated with the degree of lesions in the several groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JPEG2000 és un estàndard de compressió d’imatges que utilitza la transformada wavelet i, posteriorment, una quantificació uniforme dels coeficients amb dead-zone. Els coeficients wavelet presenten certes dependències tant estadístiques com visuals. Les dependències estadístiques es tenen en compte a l'esquema JPEG2000, no obstant, no passa el mateix amb les dependències visuals. En aquest treball, es pretén trobar una representació més adaptada al sistema visual que la que proporciona JPEG2000 directament. Per trobar-la utilitzarem la normalització divisiva dels coeficients, tècnica que ja ha demostrat resultats tant en decorrelació estadística de coeficients com perceptiva. Idealment, el que es voldria fer és reconvertir els coeficients a un espai de valors en els quals un valor més elevat dels coeficients impliqui un valor més elevat d'aportació visual, i utilitzar aquest espai de valors per a codificar. A la pràctica, però, volem que el nostre sistema de codificació estigui integrat a un estàndard. És per això que utilitzarem JPEG2000, estàndard de la ITU que permet una elecció de les distorsions en la codificació, i utilitzarem la distorsió en el domini de coeficients normalitzats com a mesura de distorsió per a escollir quines dades s'envien abans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper seeks to identify whether there is a representative empirical Okun’s Law coefficient (OLC) and to measure its size. We carry out a meta regression analysis on a sample of 269 estimates of the OLC to uncover reasons for differences in empirical results and to estimate the ‘true’ OLC. On statistical (and other) grounds, we find it appropriate to investigate two separate subsamples, using respectively (some measure of) unemployment or output as dependent variable. Our results can be summarized as follows. First, there is evidence of type II publication bias in both sub-samples, but a type I bias is present only among the papers using some measure of unemployment as the dependent variable. Second, after correction for publication bias, authentic and statistically significant OLC effects are present in both sub-samples. Third, bias-corrected estimated true OLCs are significantly lower (in absolute value) with models using some measure of unemployment as the dependent variable. Using a bivariate MRA approach, the estimated true effects are -0.25 for the unemployment sub-sample and -0.61 for the output-sub sample; with a multivariate MRA methodology, the estimated true effects are -0.40 and -1.02 for the unemployment and the output-sub samples respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper demonstrates that the ratio of the Yitzhaki (1994) to the conventional measure of between-group inequality is in general equal to one minus twice the weighted average probability that a random member of a richer (on average) group is poorer than a random member of a poorer (on average) group, and may therefore be interpreted as an index of stratification in its own right.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To test the accuracy of a new pulse oximeter sensor based on transmittance and reflectance. This sensor makes transillumination of tissue unnecessary and allows measurements on the hand, forearm, foot, and lower limb. DESIGN: Prospective, open, nonrandomized criterion standard study. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 54 critically ill neonates (gestational age 27 to 42 wks; postnatal age 1 to 28 days) with arterial catheters in place. MEASUREMENTS AND MAIN RESULTS: A total of 99 comparisons between pulse oximetry and arterial saturation were obtained. Comparison of femoral or umbilical arterial blood with transcutaneous measurements on the lower limb (n = 66) demonstrated an excellent correlation (r2 = .96). The mean difference was +1.44% +/- 3.51 (SD) % (range -11% to +8%). Comparison of the transcutaneous values with the radial artery saturation from the corresponding upper limb (n = 33) revealed a correlation coefficient of 0.94 with a mean error of +0.66% +/- 3.34% (range -6% to +7%). The mean difference between noninvasive and invasive measurements was least with the test sensor on the hand, intermediate on the calf and arm, and greatest on the foot. The mean error and its standard deviation were slightly larger for arterial saturation values < 90% than for values > or = 90%. CONCLUSION: Accurate pulse oximetry saturation can be acquired from the hand, forearm, foot, and calf of critically ill newborns using this new sensor.